the safety valve reduces pressure at for sale
One-Way Check Valve: This device allows air to flow in one direction only. All air tanks on air-braked vehicles must have a check valve located between the air compressor and the first reservoir. The check valve keeps air from going out if the air compressor develops a leak. [California Commercial Driver Handbook]
Park on level ground, chock the wheels, release the parking brake when you have enough air pressure, shut the engine off, and repeatedly press and release the brake pedal.
When performing a final check of your air brake, make sure your vehicle has low air pressure by shutting off the engine, chocking the wheels, and releasing the air pressure by pulling on and off the brakes. Continue doing so until the spring brakes come on automatically, which should be between 20 and 45 psi once you"ve confirmed the low-pressure warning is valid.
As well, the compressor in the system is capable of pumping air pressure to 500 psi (3450kPa), which poses danger to both the driver and others around the vehicle.
The driver of a commercial vehicle must know that the safety valve makes the sound of a machine gun when it releases excess air pressure from the system.
Thus, its operation is automatic; it will open only to release the pressure and not exceed the liquid force; therefore, its use is more common with fluids (although, they can also be used with vapours or moderate gases). In terms of capacity, they can withstand low pressures and their processes are continuous.
A little product education can make you look super smart to customers, which usually means more orders for everything you sell. Here’s a few things to keep in mind about safety valves, so your customers will think you’re a genius.
A safety valve is required on anything that has pressure on it. It can be a boiler (high- or low-pressure), a compressor, heat exchanger, economizer, any pressure vessel, deaerator tank, sterilizer, after a reducing valve, etc.
There are four main types of safety valves: conventional, bellows, pilot-operated, and temperature and pressure. For this column, we will deal with conventional valves.
A safety valve is a simple but delicate device. It’s just two pieces of metal squeezed together by a spring. It is passive because it just sits there waiting for system pressure to rise. If everything else in the system works correctly, then the safety valve will never go off.
A safety valve is NOT 100% tight up to the set pressure. This is VERY important. A safety valve functions a little like a tea kettle. As the temperature rises in the kettle, it starts to hiss and spit when the water is almost at a boil. A safety valve functions the same way but with pressure not temperature. The set pressure must be at least 10% above the operating pressure or 5 psig, whichever is greater. So, if a system is operating at 25 psig, then the minimum set pressure of the safety valve would be 30 psig.
Most valve manufacturers prefer a 10 psig differential just so the customer has fewer problems. If a valve is positioned after a reducing valve, find out the max pressure that the equipment downstream can handle. If it can handle 40 psig, then set the valve at 40. If the customer is operating at 100 psig, then 110 would be the minimum. If the max pressure in this case is 150, then set it at 150. The equipment is still protected and they won’t have as many problems with the safety valve.
Here’s another reason the safety valve is set higher than the operating pressure: When it relieves, it needs room to shut off. This is called BLOWDOWN. In a steam and air valve there is at least one if not two adjusting rings to help control blowdown. They are adjusted to shut the valve off when the pressure subsides to 6% below the set pressure. There are variations to 6% but for our purposes it is good enough. So, if you operate a boiler at 100 psig and you set the safety valve at 105, it will probably leak. But if it didn’t, the blowdown would be set at 99, and the valve would never shut off because the operating pressure would be greater than the blowdown.
All safety valves that are on steam or air are required by code to have a test lever. It can be a plain open lever or a completely enclosed packed lever.
Safety valves are sized by flow rate not by pipe size. If a customer wants a 12″ safety valve, ask them the flow rate and the pressure setting. It will probably turn out that they need an 8×10 instead of a 12×16. Safety valves are not like gate valves. If you have a 12″ line, you put in a 12″ gate valve. If safety valves are sized too large, they will not function correctly. They will chatter and beat themselves to death.
Safety valves need to be selected for the worst possible scenario. If you are sizing a pressure reducing station that has 150 psig steam being reduced to 10 psig, you need a safety valve that is rated for 150 psig even though it is set at 15. You can’t put a 15 psig low-pressure boiler valve after the reducing valve because the body of the valve must to be able to handle the 150 psig of steam in case the reducing valve fails.
The seating surface in a safety valve is surprisingly small. In a 3×4 valve, the seating surface is 1/8″ wide and 5″ around. All it takes is one pop with a piece of debris going through and it can leak. Here’s an example: Folgers had a plant in downtown Kansas City that had a 6×8 DISCONTINUED Consolidated 1411Q set at 15 psig. The valve was probably 70 years old. We repaired it, but it leaked when plant maintenance put it back on. It was after a reducing valve, and I asked him if he played with the reducing valve and brought the pressure up to pop the safety valve. He said no, but I didn’t believe him. I told him the valve didn’t leak when it left our shop and to send it back.
When it came back, I laid it down on the outlet flange and looked up the inlet. There was a 12″ welding rod with the tip stuck between the seat and the disc. That rod was from the original construction and didn’t get blown out properly and just now it got set free. The maintenance guy didn’t believe me and came over and saw it for himself (this was before cell phones when you could take a picture).
If there is a problem with a safety valve, 99% of the time it is not the safety valve or the company that set it. There may be other reasons that the pressure is rising in the system before the safety valve. Some ethanol plants have a problem on starting up their boilers. The valves are set at 150 and they operate at 120 but at startup the pressure gets away from them and there is a spike, which creates enough pressure to cause a leak until things get under control.
If your customer is complaining that the valve is leaking, ask questions before a replacement is sent out. What is the operating pressure below the safety valve? If it is too close to the set pressure then they have to lower their operating pressure or raise the set pressure on the safety valve.
Is the valve installed in a vertical position? If it is on a 45-degree angle, horizontal, or upside down then it needs to be corrected. I have heard of two valves that were upside down in my 47 years. One was on a steam tractor and the other one was on a high-pressure compressor station in the New Mexico desert. He bought a 1/4″ valve set at 5,000 psig. On the outlet side, he left the end cap in the outlet and put a pin hole in it so he could hear if it was leaking or not. He hit the switch and when it got up to 3,500 psig the end cap came flying out like a missile past his nose. I told him to turn that sucker in the right direction and he shouldn’t have any problems. I never heard from him so I guess it worked.
If the set pressure is correct, and the valve is vertical, ask if the outlet piping is supported by something other than the safety valve. If they don’t have pipe hangers or a wall or something to keep the stress off the safety valve, it will leak.
There was a plant in Springfield, Mo. that couldn’t start up because a 2″ valve was leaking on a tank. It was set at 750 psig, and the factory replaced it 5 times. We are not going to replace any valves until certain questions are answered. I was called to solve the problem. The operating pressure was 450 so that wasn’t the problem. It was in a vertical position so we moved on to the piping. You could tell the guy was on his cell phone when I asked if there was any piping on the outlet. He said while looking at the installation that he had a 2″ line coming out into a 2×3 connection going up a story into a 3×4 connection and going up another story. I asked him if there was any support for this mess, and he hung up the phone. He didn’t say thank you, goodbye, or send me a Christmas present.
Pipe dope is another problem child. Make sure your contractors ease off on the pipe dope. That is enough for today, class. Thank you for your patience. And thank you for your business.
Safety valves and pressure relief valves are crucial for one main reason: safety. This means safety for the plant and equipment as well as safety for plant personnel and the surrounding environment.
Safety valves and pressure relief valves protect vessels, piping systems, and equipment from overpressure, which, if unchecked, can not only damage a system but potentially cause an explosion. Because these valves play such an important role, it’s absolutely essential that the right valve is used every time.
The valve size must correspond to the size of the inlet and discharge piping. The National Board specifies that the both the inlet piping and the discharge piping connected to the valve must be at least as large as the inlet/discharge opening on the valve itself.
The connection types are also important. For example, is the connection male or female? Flanged? All of these factors help determine which valve to use.
The set pressure of the valve must not exceed the maximum allowable working pressure (MAWP) of the boiler or other vessel. What this means is that the valve must open at or below the MAWP of the equipment. In turn, the MAWP of the equipment should be at least 10% greater than the highest expected operating pressure under normal circumstances.
Temperature affects the volume and viscosity of the gas or liquid flowing through the system. Temperature also helps determine the ideal material of construction for the valve. For example, steel valves can handle higher operating temperatures than valves made of either bronze or iron. Both the operating and the relieving temperature must be taken into account.
Back pressure, which may be constant or variable, is pressure on the outlet side of the pressure relief valve as a result of the pressure in the discharge system. It can affect the set pressure of the upstream valve and cause it to pop open repeatedly, which can damage the valve.
For installations with variable back pressure, valves should be selected so that the back pressure doesn’t exceed 10% of the valve set pressure. For installations with high levels of constant back pressure, a bellows-sealed valve or pilot-operated valve may be required.
Different types of service (steam, air, gas, etc.) require different valves. In addition, the valve material of construction needs to be appropriate for the service. For example, valves made of stainless steel are preferable for corrosive media.
Safety valves and relief valves must be able to relieve pressure at a certain capacity. The required capacity is determined by several factors including the geometry of the valve, the temperature of the media, and the relief discharge area.
These are just the basic factors that must be considered when selecting and sizing safety valves and relief valves. You must also consider the physical dimensions of the equipment and the plant, as well as other factors related to the environment in which the valve will operate.
A pressure safety valve actuated by inlet static pressure and characterized by rapid opening or rapid popping action. This safety valve is tight shut-off and is for safety only. Meets ASME SEC. VIII (Not a Fulflo valve)
A spring loaded pressure relief valve, actuated by the static pressure upstream of the valve. The valve opens normally in proportion to the increase in pressure over the set pressure. (Fulflo)
A pressure relief valve characterized by rapid opening or pop-action in direct proportion to the pressure increase, depending on the application. (Fulflo)
The pressure existing at the outlet of a pressure relief valve, due to the pressure in the discharge system. The pressure can be constant or variable. It is the sum of the superimposed and build-up pressure.
The pressure existing at the outlet of the relief device at the time the device is required to operate. It is a result of pressure in the discharge system coming from another source. This pressure may be constant or variable.
Fulflo was established in 1912 and is celebrating its 100th anniversary. Located in Blanchester, OH, Fulflo was incorporated in 1933 under its present name and trademark. Patents for the original guided piston, direct acting relief valve were obtained in 1935, coinciding with the onset of fluid power systems. The need for providing large flows without excessive bulk was met by the pilot-valve-control relief valve which was patented in 1943.
Fulflo parts and valves are used in oil and gas refineries, are essential to the military, including ships and aircraft carriers, and amusement roller coaster rides.
Industry leading pressure and safety relief valve designs with over 140 years of technical and application expertise providing custom engineered solutions for O&G, Refining, Chemical, Petrochemical, Process and Power applications. Our designs meet global and local codes and standards (API 526; ASME Section I, IV & VIII; EN ISO 4126; PED & more). Gain insight into the performance of your pressure relief valves with wireless monitoring.
As valves operate to regulate the flow inside pipelines, there is sometimes a need to release the pressure or fluids from the system. The Boiler pressure relief valve is such a valve that has to operate in a manner when high pressure has built up or the time has come to release the fluids. The valves hold the pressure until a certain time to release the fluid. This is a Safety valve that is deployed to make sure that the fluid can be drained when necessary. In an instance, the safety valve should be able to open up the lines and release the fluid, draining the system as quickly as possible.
This is one of the main functions of a Pressure safety valve. If you attach a pressure gauge to a system and leave it there for an extended period of time, you’ll likely notice that pressure drops and flow are reduced. If this occurs in your system and you’re not doing something to relieve it, you could damage or collapse your pipes or fittings. A Safety relief valve does exactly that, by releasing the built-up pressure back into the system automatically.
A water hammer is a condition caused by a surge of flow back into a system after a sudden pressure drop if there is no Boiler safety valve installed in the boiler. This occurs when there is not enough flow to relieve the sudden pressure drop and a water hammer can occur. This can cause damage to plumbing by knocking your pipes out of alignment. When installing a pressure relief valve, it’s important to make sure there is enough flow through the system so the pressure doesn’t drop again. In order to prevent a water hammer, you’d have to have a constant flow of water through your system and a Pressure relief device has to be installed. This is where the release valve comes in.
The two most important things to know about any Boiler relief valve are that it must be used as a safety valve and that it must not be confused with a pressure relief valve. A bypass valve is designed to function as a bypass, not as a pressure relief valve. One disadvantage is that a bypass valve should never be used as an Air compressor pressure relief valve. In addition to the safety concerns associated with using a bypass valve as a pressure relief valve, it is important to remember that a bypass valve is not designed to release large amounts of water. If you use a bypass valve as a pressure relief valve, the valve could burst and release a large amount of water.
The next bit of information you’ll want to know about is the boiler relief valve. This valve is predominantly used in steam heating systems. As the boiler passes water through the system, it generates pressure. Just like in a system with an Air compressor safety valve, that pressure can build up and damage your pipes or fittings if it isn’t relieved. The boiler relief valve is what the system uses to relieve the pressure. In a similar way, there are valves used in air compression systems. To safeguard these systems an Air compressor relief valve is used to relieve the pressure from the air compression system.
Safety valves are designed to open under certain pressure. According to the valve manufacturer, the pressure should be less than the maximum working pressure of the system. If the pressure rises above that maximum working pressure, the Water heater safety valve should open, releasing the pressure back into the system. Safety valves are typically found on outdoor water systems and are meant to open when the water temperature rises above a certain point or when a specific amount of pressure is reached. These valves can also be found in other systems in applications like pharmaceutical, wastewater management, oil and gas, and in power generation.
Bendix Commercial Vehicle Systems LLC (“ BENDIX,” “ we,” “ our” ) is committed to taking reasonable steps to protect your privacy. This Privacy Statement applies to your interaction with our websites, www.bendix.com, www.bendix.biz, www.b2Bendix.com our social media activities, and other sources, and describes how we collect, process, use, and disclose your personal information. For purposes of this Privacy Statement, “ personal information” means information from or about you that identifies you directly and information that is associated with you and thus could potentially identify you, including when combined with other information from or about you.
BENDIX is a U.S.-based company that conducts business with U.S. and international consumers. As a result, personal information that we collect and personal information that we receive from consumers may be transferred to our U.S. offices to permit us to comply with our legal and contractual obligations, to provide information and services to prospective and current consumers, and to perform related business services. In addition, we may transfer personal information to third-party service providers and business partners, in the U.S. and in other countries, to the extent necessary to support BENDIX’s business activities. Thus, personal information that we collect may be transferred to and stored on servers located in the United States and in countries different from the country in which that information was initially collected. Similarly, personal information may be accessed by BENDIX and its third-party service providers and business partners from countries other than the ones in which the personal information is stored.
IF YOU HAVE ANY COMMENTS OR QUESTIONS ABOUT THIS PRIVACY STATEMENT OR OUR INFORMATION COLLECTION AND DATA PROTECTION PRACTICES, PLEASE CONTACT US BY EMAIL AT Privacy@Bendix.com.
We may obtain personal information with which you voluntarily provide us when you register for an account, purchase our products and services, interact with us on social media, sign up for one of our newsletters, participate in a website promotion, contest, or survey, submit a web form. This information may include your name, address, phone number, e-mail address, location, and IP address.
We use this information to administer your account, fulfill orders and facilitate delivery, provide customer support, improve the quality and security of our services, verify your compliance with the obligations in our Terms of Use and related policies, provide updated information about our products, or otherwise submit information to us.
If you transact business with us, for example by purchasing our products or services, we collect information about the transactions. The information we collect includes your payment information, such as your name, telephone number, e-mail address, discount code, billing information, shipping information, and other related information. We may retain limited information in order to respond to fulfillment questions or inquiries, communicate with you about your account, and for other business purposes.
If you contact us via telephone, e-mail, fax, our website, social media, or in any other way, we may retain the communication and the information it contains. This information may be used to respond to your inquiry, to notify you of BENDIX products, services, and news, for marketing purposes, or for other business purposes. If you do not wish to receive notifications about BENDIX products, services, and news, or otherwise want to restrict the use of information you provide to us, please e-mail us at Privacy@Bendix.com, or write to us at the address shown below.
If you make a purchase and request that it be shipped to another person, you confirm and acknowledge that we may collect the name, telephone number, e-mail address, and shipping information of the recipient. We use this information to help facilitate product fulfillment and for other legitimate business purposes.
We also may receive information about you from third-party social platforms such as Facebook, Twitter, LinkedIn, Instagram, or other platforms. When you interact with the website through a third-party social platform, you allow the platform to collect information about your interaction with the website and you allow us to access or collect information made available by the platform in accordance with its Privacy Statement. This information may be available from your third-party social platform profile or account, or from cookies placed on your browser by the third-party platform.
We and our third-party service providers may use a variety of technologies, such as cookies, web beacons, embedded scripts, and eTags (" Tracking Technologies" ), that automatically collect and store certain information whenever you visit or interact with the website, view or click on advertisements, or visit our social media pages. This includes log data that automatically records information about your visit, such as your browser type, operating system, the URL of the page that referred you, the different actions you performed, and the IP address you used to access pages on the website. We use this information to administer the website, analyze trends, provide you with an experience that is relevant to your location based on the IP address (e.g., to direct you to the appropriate shopping cart that services your country), gather information about visitor movements, help diagnose potential problems with our server, investigate actual or potential security incidents, and ensure that the website is working properly. In addition, and for the same reasons, we may collect information about your browsing behavior, such as the date and time you visit the website, the areas or pages of the website that you visit, the amount of time you spend viewing the website, the number of times you return to the website, and other clickstream data.
We may assign your device one or more cookies to facilitate access to our website and to personalize your online experience. A cookie is a small text file that is stored on a user"s computer or mobile device for record keeping purposes. A flash cookie is similar to a cookie, but it can store more complex data in order to remember settings, preferences, and usage. Cookies can be either session cookies or persistent cookies. We may use both session cookies (which expire once you close your browser) and persistent cookies (which stay on your devices until you delete them) to: (1) allow you to use the website without having to re-enter your user name and password ; (2) enhance or personalize your website usage ; (3) monitor website usage ; (4) manage the website ; and (5) improve the website and our products and services. These cookies may be delivered by us or by third parties.
We also may use web beacons on the website, in our e-mails and in our advertisements on other websites. Web beacons are tiny graphic images that are used to collect information about your website visit, such as the pages you view and the features you use, as well as information about whether you open and/or act upon one of our e-mails or advertisements. We may also collect the URL of the website you visited immediately before coming to the website. Web beacons help us analyze our website visitors" behavior and measure the effectiveness of the website and our advertising. We may combine the non-personal information we collect through cookies and web beacons with other information we have collected from you. We also may work with service providers that help us track, collect and analyze this information.
Our website may use Google Analytics, a web analytics service provided by Google, Inc. (" Google" ). Google uses cookies to help us analyze how visitors use the website. The information generated by the cookie about your use of the website is generally transmitted to and stored on a Google server in the U.S. In case of activation of IP anonymization, Google will, however, truncate/anonymize the last eight-bit segment of your IP address beforehand within Member States of the European Union or other parties to the Agreement on the European Economic Area. Only in exceptional cases will the full IP address be transmitted to a Google server in the US and truncated there. On behalf of the operator of the website, Google will use this information for the purpose of evaluating your use of the website, compiling reports on the website activity, and providing the operator with other services relating to the website and Internet use. Google will not associate your IP address with any other data held by Google. You may manage and opt out of Google’s use of cookies by visiting Google’s Ads settings and selecting the appropriate settings in your browser. However, please note that if you do so, you may not be able to use the full functionality of the website. Alternatively, you can prevent Google’s collection and use of data by downloading and installing the browser plugin available at: http://tools.google.com/dlpage/gaoptout?hl=en and/or opt out by visiting the Network Advertising Initiative opt-out page: http://www.networkadvertising.org/choices/. Please note that if you disable the use of cookies, you may not be able to use the full functionality of the website. For further information on Google’s terms of use and data protection/privacy, please see https://www.google.com/policies/privacy/, http://www.google.com/analytics/terms/us.html, and http://www.google.com/analytics/learn/index.html.
Social Media Our website as well as the websites of our third-party service providers, interface with social media websites such as Facebook, Instagram, LinkedIn, YouTube, and Twitter and may use social media plugins (such as the Facebook " Like" button) to facilitate social media functions. When you visit our website, the operator of a social media plugin may set cookies or other tracking technology on your browser, enabling that social media operator to recognize users who visit our website. If you are logged into a social media website while browsing on our website, the social media plugins may allow the social media website to receive information about your visit-including the pages that you viewed-and connect the visit to your personal information. This allows us to share information about your activities on our website with other users of their social media website. For example, Facebook social media plugins allow Facebook to show your Likes and comments on our website to your Facebook friends. Your use of social media plugins is subject to each social media website"s Privacy Statement, so we encourage you to use care and thoughtfully read the Privacy Statement of each social media website that you use. We have no control over the information that social media websites or plugins collect, store, or use. Before connecting to our website from a social media website or using a social media plugin on our website, please be certain that you understand the social media website"s Privacy Statement and how it may gather information about your use of our website.
You may choose not to provide us with your information, in which case we will not be able to provide you with additional information or publications or respond to your queries.
If you provide us with your information, but later decide that you do not want to receive marketing or other informational communications from us, or if you wish to discontinue your subscription to an email or newsletter, you may send an email us at Privacy@Bendix.com, or writing to us at the address shown below.
Some browsers have a " Do Not Track" feature that lets you tell websites that you do not want to have your online activities tracked. These features are not yet uniform. Although we do not at this time honor “ Do Not Track” signals from a web site browser, we offer you a choice about whether to accept cookies from our website, and you may refuse, or later delete, cookies. Please refer to your browser’s Help instructions to learn more about cookies and other technologies and how to manage their use. If you elect to refuse or delete cookies, you will need to repeat this process each time you use a different computer or change browsers. If you choose to decline cookies, some of your online functionality may be impaired.
Except to the extent necessary to fulfill our business obligations, we do not sell, transfer, or otherwise disclose to third parties any of the personal information that we collect directly from or about you.
We may transfer information to third-party service providers and business partners to the extent necessary to help us comply with our legal and contractual obligations, to provide information and services to prospective and current clients, and to perform related business services such as removing repetitive information from customer lists, analyzing data, providing marketing assistance, providing search results and links, processing credit card payments, and providing customer service.
In addition, we may disclose information collected from and about you as follows: (1) you expressly request or authorize us to do so ; (2) we believe the information is needed to comply with the law (for example, to comply with a search warrant, subpoena or court order), respond to a government request, enforce an agreement we have with you, or to protect our rights, property or safety, or the rights, property or safety of our employees or others ; (3) the information is provided to our agents, third parties or service providers who perform functions on our behalf ; (4) to address emergencies or acts of God ; (5) in anticipation of and in the course of an actual or potential sale, reorganization, consolidation, merger, or amalgamation of all or part of our business or operations in which case your information may be provided to the purchaser or resulting entity ; or (6) to address disputes, claims, or to persons holding a legal or beneficial interest.
How Do We Protect Personal Information? We maintain reasonable risk-based physical, technical, and administrative safeguards to protect against unauthorized and accidental disclosure, use, alteration, or destruction of personal information in our possession, and to maintain the confidentiality, integrity, availability, and resilience of our systems, data, and services.
Unfortunately, no data transmission over the Internet can be guaranteed to be 100% secure. Accordingly, and despite our reasonable security measures, we cannot guarantee or warrant the security of any information that you transmit to us using email or using insecure or unencrypted means of contacting us and interacting with our website and our online services.
If you are a California resident, you have the right to request information regarding the manner in which BENDIX shares certain categories of your personal information with third parties, for the third parties’direct marketing purposes.
Under California Civil Code Section 1789.3, California users of the Services are entitled to the following specific consumer rights notice: The Complaint Assistance Unit of the Division of Consumer Services of the California Department of Consumer Affairs may be contacted in writing at 1625 North Market Blvd., Suite N 112, Sacramento CA 95834, or by telephone at (916) 445-1254 or (800) 952-5210.
California law provides that you have the right to submit a request to us by email to Privacy@Bendix.com or by writing to us at the address shown below, and receive the following information: Bendix Commercial Vehicle Systems LLC
The categories of information that we disclosed to third parties for the third parties’direct marketing purposes during the preceding calendar year ; and
The names and addresses of the third parties that received such information, or if the nature of their business cannot be determined from the name, then examples of the products or services marketed.
The website is not intended for use by, or targeted at, children under 16, and we do not knowingly or intentionally collect information about children under 16. If we become aware that we have unknowingly collected personally identifiable information from a child under the age of 16, we will make reasonable efforts to return or delete such information from our records. Please direct any such notifications to us by e-mail at Privacy@Bendix.com or by writing to the address shown below. Bendix Commercial Vehicle Systems LLC
We may provide links to third-party websites that do permit children under the age of 16 to register for use of their websites. In such instances, the third parties are responsible for ensuring that their websites comply with applicable laws, regulations, and rules.
This Privacy Statement only addresses our use and disclosure of your personal information. Occasionally we provide links to other websites for your convenience and information. These sites operate independently from BENDIX and are not under our control. These sites may have their own privacy notices in place, which we strongly suggest you review if you visit any linked websites. Except to the extent that a third party is providing services on our behalf, we are not responsible for the content of these sites, any products or services that may be offered through these sites, or any other use of these sites.
We retain personal information only as is necessary for the purpose for which the data was collected. We also keep information as otherwise required by law.
You can update, correct, or delete your personal information, or remove it from our system by emailing us at Privacy@Bendix.com or writing to us at the address shown below. Bendix Commercial Vehicle Systems LLC
Requests typically receive a response within thirty (30) days. If the request cannot be resolved provided within that time frame, we will provide the requesting party with an estimated date by which the information will be provided. If for some reason access is denied, we will provide an explanation of why access has been denied.
As BENDIX and its websites, products, and services change from time to time, this Privacy Statement is expected to change as well. We will notify you of changes to this Privacy Statement by posting the amended Privacy Statement on the website at least thirty (30) days before the effective date of the changes. If you have provided us with your e-mail address, we may also notify you of any material changes to the Privacy Statement that affect your rights by sending an e-mail at least thirty (30) days before the effective date of the changes to the e-mail address you most recently provided to us. We encourage you to keep the e-mail address you provide to us current, and to promptly notify us of any changes to your e-mail address, so that you may receive any notices we send to you regarding material changes to this Privacy Statement. If you do not agree to the new Privacy Statement, you should stop using the affected website(s), and if you are a registered user, you may cancel your account with us within the thirty (30) day period by e-mailing us at Privacy@Bendix.com or writing to us at the address shown below: Bendix Commercial Vehicle Systems LLC
and you will not be bound by the new Privacy Statement. Otherwise, the new Privacy Statement will take effect after thirty (30) days. Our employees do not have the right to modify this Privacy Statement orally or otherwise. If any employee of ours offers to modify the provisions of this Privacy Statement except using the process described above, he or she is not acting as an agent for us or speaking on our behalf.
To the extent additional notice is required by law or otherwise, BENDIX may deliver a general notice on this website, by means of an e-mail, or by other method to the address that you have provided to BENDIX.
You may not worry often, if at all, about whether or not your air compressor is running safely. And you really don’t have to, because compressor manufacturers do. From the pressure rating on the air storage tank to emergency stop buttons, air compressors are designed with safety in mind.
But that doesn’t mean you should never think about your compressor’s safety features. In most cases, they need to be inspected regularly to make sure they’re working properly. One key safety feature that should be inspected regularly is the air pressure relief valve (PRV), sometimes called a safety relief valve.
The pressure relief valve is a safety valve that protects the compressor component that it’s attached to from being exposed to a pressure above its rated maximum operating pressure. This rating, called the maximum working pressure (MWP), is the pressure that the vessel has been certified to continuously operate at safely.
So when a compressor is running at or below its maximum working pressure—in other words, when it’s running “normally”—the relief valve doesn’t do anything.
However, when the air pressure inside a compressor exceeds its MWP, the pressure relief valve will activate to “blow off” the excessive pressure within the compressor. Without a relief valve, the storage tank could rupture from the excessive pressure, damaging the compressor itself, possibly other property near it, and even causing injuries (or worse) to anyone standing nearby.
Before we can talk about how the air pressure relief valve works, we first need to look at how air pressure inside a compressor is managed when everything is running normally.
Under normal circumstances, the air pressure in a compressor is controlled by a pressure switch in an electro/mechanical control system or, in the case of an electronic controller, a pressure transducer and controller settings. When the cut-out set pressure for the pressure switch is reached, the compressor will stop compressing air (unload) until the cut-in set pressure is reached, at which time it will start compressing air again (load). If the pressure switch fails, the compressor would not be able to start compressing air again, or potentially worse, not be able to stop. Most compressors also have a high-pressure safety switch that should stop the compressor if the pressure exceeds the unload set point.
A pressure relief valve is a straightforward safety backup to the pressure switch and high-pressure switch, or the controller set points, should any of these components fail with the compressor running. The safety relief valve is set above the high-pressure safety switch and generally at or below the vessel’s maximum operating pressure. Inside the valve is a spring, and the pressure created by the spring’s tension keeps the valve closed under normal operating conditions. However, as the air pressure increases in pressure vessels (like the storage tank), it eventually exceeds the rated pressure of the relief valve, causing the relief valve to open and the excess pressure to be “blown off” to the atmosphere.
If the pressure relief valve fails open, air will continually vent to the atmosphere, preventing the air stream from becoming fully pressurized. The compressor should be shut down and the relief valve replaced before the compressor is restarted. The open relief valve will likely cause a loss of production and possible danger to personnel as a result of the flow of high-pressure air with flying debris and an unsafe sound level.
A pressure relief valve failing closed presents a potentially more dangerous situation. As noted earlier, the relief valve exists to allow excessive pressure to be “blown off” so that the air pressure inside the compressor’s pressure vessels don’t exceed their rated specifications. If the valve fails closed, this pressure venting can’t happen. Unless compressed air demand matches the compressed air supply, the pressure inside the compressor will continue to build. Eventually, the pressure increase would cause the storage tank to rupture, damaging the compressor and possibly causing additional damage and injury to property and people nearby.
If the relief valve is opening because the air pressure in the compressor has exceeded the valve’s pressure set point, that means the valve is working and doing what it was designed to do. But because this indicates the MWP of the compressor has been exceeded, the condition that’s causing excessive pressure should be diagnosed and corrected.
If the relief valve opening wasn’t caused by excessive pressure inside the compressor, then the valve is most likely “failing open”. Most likely, this is because the valve has become “soft” over time, i.e. the valve spring is providing less counterpressure, so it’s opening at a lower pressure than it should.
Whether the valve opened because of excessive pressure in the compressor or because the valve is failing, you should have your local air compressor distributor inspect your compressor before running it again for two reasons:
First, your distributor can determine whether the valve opened due to a failing relief valve or excessive compressors pressure and perform any needed maintenance or service to get your compressor running efficiently and safely again.
Second, regardless of why the pressure relief valve opened, replacing it may be recommended to ensure safe compressor operation, depending on the valve manufacturer. (Replacement is recommended for Sullair compressors.)
Important: Running the compressor after the relief valve has opened, regardless of the reason why it opened, can put both your property at risk of damage and people at risk of injury (or worse). While this may be obvious if the compressor is building up excess pressure, it also applies if the valve failed open. As noted above, even a valve that fails open poses some risk, and next time it could fail closed.
Given how critical a working air pressure relief valve is to the safe and efficient operation of your air compressor, you may wonder whether you need to do any regular inspecting or testing of the valve to make sure it is working. Because this can vary by manufacturer, you should consult your owner’s manual or contact your local air compressor distributor for frequency and type of inspection needed. For most Sullair compressors, inspection for damage or leakage is recommended, but testing is not recommended, as doing so may compromise the valve’s performance.
However, one thing you should do is schedule regular maintenance with your local air compressor distributor. As part of regular maintenance, a service technician can inspect the PRV and let you know it’s at an age or in a condition at which the manufacturer recommends replacement. Also, problems with the compressor’s performance, e.g. not reaching normal operating pressure, may help the service technician identify a failing relief valve after ruling out other possible causes.
When a pressure vessel like a receiver, sump tank or other storage vessel is purchased separately from the compressor, it may not be supplied with a pressure relief valve. To ensure its safe operation, you should add a PRV.
When selecting a PRV to add to the pressure vessel, you must choose a valve with a pressure set point set at or below the maximum working pressure of the vessel. You will find the MWP (and other useful information) on a tag welded to the pressure vessel. Also, flow capacity of the PRV must meet or exceed the total compressed air supplied to the vessel.
For example, if you have two compressors with capacities of 500 and 750 cfm (14.2 and 21.2 m³/min), and a pressure vessel with a maximum working pressure of 200 psi (13.8 bar), the minimum settings for a pressure relief valve would be 1250 cfm (35.4 m³/min) and a set point 200 psi (13.8 bar) or less.
Finally, when attaching the valve to the vessel, the porting must not be reduced to a size less than the size of the inlet port of the pressure relief valve.
Because the pressure relief valve is critical to the safe operation of your compressed air system, if you’re not sure how to select the correct PRV and properly and safely add it to the pressure vessel, contact your local air compressor distributor. They have the experience and expertise to ensure that the PRV is sized and installed correctly.