ari safety valve manual factory

Direct Loaded Safety Valves for blowing off excess pressure of steam, vapor, gases, and liquid from pressure vessels, steam boiler, hot water boiler and piping systems. ARI-SAFE safety valves are available in full-stroke and normal versions.

Our safety valves are available with metal or soft seated plugs, with precise centering and guiding. Materials include cast iron, cast steel, and stainless steel. Call us for further options!

ari safety valve manual factory

We specialize in thermal heat transfer fluid (hot oil) valves, known in the ARI-Armaturen family as the FABA product line. These are commonly found anywhere heat transfer is required whether for the manufacture of engineered wood, chemicals, automobiles, coatings, fibers and non-woven textiles, asphalt, industrial cooking, and a host of other industries. Other ARI-Armaturen products are found in similar applications and industries, and we can assist you with these as well.

ari safety valve manual factory

ARI can look back on a tradition of more than sixty years as a partner for control, isolation, safety and steam trapping of liquid and gaseous media. Are you looking for product solutions specially tailored to your individual requirements? Profit from our "one-stop shop" philosophy.

ari safety valve manual factory

ARI-SAFE Safety valve Full lift safety valve / Standard safety valve ARI-SAFE Full lift safety valve D/G Standard safety valve F • Type-test approved acc. to DIN EN ISO 4126 / AD2000-A2 • TÜV · SV · . . -663 · D/G Figure 901-912 • TÜV · SV · . . -663 · F Figure 901/911 • Further approvals: see inside ARI-SAFE Standard safety valve for the heating technology • Type-test approved acc. to TRD 721 • TÜV · SV · . . -688 · D/G/H Figure 903 • TÜV · SV · . . -688 · D Figure 904 ARI-SAFE-P Standard safety valve D/G/F • Type-test approved acc. to DIN EN ISO 4126 / AD2000-A2 • TÜV · SV · . . -811 · D/G Figure 921-924 • TÜV · SV · . . -811 · F Figure 921/923 ARI-SAFE-TC Full lift safety valve D/G Standard safety valve F • Type-test approved acc. to DIN EN ISO 4126 / AD2000-A2 • TÜV · SV · . . -995 · D/G Figure 941-943 • TÜV · SV · . . -995 · F Figure 941/943 ARI-SAFE-TC Standard safety valve for the heating technology • Type-test approved acc. to TRD 721 • TÜV · SV · . . -997 · D/G/H Figure 945 • TÜV · SV · . . -997 · D Figure 946 ARI-SAFE-TCP Standard safety valve D/G/F • Type-test approved acc. to DIN EN ISO 4126 / AD2000-A2 • TÜV · SV · . . -1041 · D/G Figure 961-963 • TÜV · SV · . . -1041 · F Figure 961/963 ARI-SAFE-TCS Standard safety valve D/G/F • Type-test approved acc. to DIN EN ISO 4126 / AD2000-A2 • TÜV · SV · . . -1041 · D/G Figure 951-953 • TÜV · SV · . . -1041 · F Figure 951/953 FOR HORIZONTAL APPLICATION Edition 11/12 - Data subject to alteration Features: • Direct loaded with spring • Wear resistant seat/disc • Precision disc alignment and guide • Possible with soft seal disc • Possible with EPDM bellow 953 • Possible with stainless steel bellow Page 28 • ARI-SAFE-TC/TCP/TCS: All common thread types Data sheet 900001 englisch (english)

Fig. 901 / 902 / 911 / 912 ARI-SAFE - Full lift safety valve D/G, Standard safety valve F Figure Nominal pressure Nominal diameter Temperature range Flange holes/thickness tolerances DIN 2533/2533 DIN 28607/28605 DIN 2545/2543 DIN 2545/2543 Type-test approval Full lift safety valve: TÜV · SV · . . -663 · D/G (Fig. 901/902/911/912) Standard safety valve: TÜV · SV · . . -663 · F (Fig. 901/911) Set gauge pressure refer to „Capacity“. Requirement Acc. to EN ISO 4126-1, VdTÜV-leaflet 100, AD2000-A2, TRD 421, material selection observe TRB 801 No. 45!! Construction Safety valve, spring loaded,...

Fig. 901 / 902 / 911 / 912 Dimensions and weights DN1/DN2 (mm) 20/32 18 d0 (mm) 254 A0 (mm2) 85 l (mm) 95 l1 (mm) 270 H (mm) 310 H (Bellow design) (mm) 150 X (mm) G 1/4“ Drainhole with plug 1) (inch) 8,5 Weight (kg) 9,5 Weight (Bellow design) (kg) Standard-flange dimensions refer to page 34. 1) Spring ranges: Standard design (barg) DN20 DN25 - 50 DN65 DN80 Spring ranges: Bellow design (barg) DN20 DN25 DN32 DN40 Design with bellow as standard valve (only Fig. 901/911) Description Body Seat Studs Spindle guide Hexagon nut Bonnet, closed 12 Disc unit 14 Spindle * 17 Adjusting screw 28 Cap,...

Capacity Fig. 901 / 911 Capacity water incl. 10% overpressure Gauge press. ← max. set pressure stainless steel version Certified coefficient of discharge Kdr (Values for D/G variable: DN20-100 < 3,5 bar, DN125-150 < 4,0 bar) Kdr D/G Edition 11/12 - Data subject to alteration

ARI-SAFE - Heating-safety valve Figure Nominal pressure Nominal diameter Temperature range Flange holes/thickness tolerances DIN 2533/2533 Type-test approval spring loaded: TÜV · SV · . . -688 · D/G/H Set gauge pressure refer to „Capacity“. Requirement Acc. to TRD 721 Part 6, material selection observe TRD! (EN-JL1040 max. 10 bar; >10 bar 25.903 EN-JS1049 or 35.903 1.0619+N) Application Acc. to DIN EN 12828 Heating systems in buildings Constructions Standard safety valve, spring loaded, direct loaded metal seat with EPDM insert, EPDM-bellow, closed spring bonnet with control hole, open...

Dimensions and weights DN1/DN2 (mm) 20/32 18 d0 (mm) 254 A0 (mm2) 85 l (mm) 95 l1 (mm) 270 H (mm) 150 X (mm) G 1/4“ Drainhole with plug (optional) (inch) 8,5 Weight (kg) Standard-flange dimensions refer to page 34. Parts Pos. Description 1 Body 2 Seat 3 Studs 4 Spindle guide 8 Hexagon nut 11 Bonnet, closed 12 Disc unit 14 Spindle * 17 Adjusting screw 29 Cap, open 37 Spring * 41 Lever, open 43 Bellow * Spare parts Information / restriction of technical rules need to be observed! ARI-Valves of EN-JL1040 are not allowed to be operated in systems acc. to TRD 110. A production allowance acc. to...

Capacity Fig. 903 Capacity water Water 20°C (kg/h) ^ Sizing: 1 l/h = 1 kW Sizing safety valves for the volume flow of water expansion (DIN 4751 p2 - item 8.1) Edition 11/12 - Data subject to alteration

ARI-SAFE - Low pressure steam - safety valve Figure Nominal pressure Nominal diameter Temperature range Flange holes/thickness tolerances DIN 2533/2533 Type-test approval Low pressure steam - safety valve: TÜV · SV · . . -688 · D Set gauge pressure refer to „Capacity“. Requirement Acc. to TRD 721 Part 5 Application For low pressure steamgenerators up to 1 bar, DIN 4750 and DIN EN 12828 Heating systems in buildings Construction Standard safety valve, spring loaded, direct loaded, EPDM-bellow, closed bonnet with control hole, open lifting device, stainless steel seat and spindle Sizing refer...

ari safety valve manual factory

ISO 9001 certified distributor of valves including bellow seal, DIN/ANSI control, safety, pressure regulating, reducing, strainers, check, butterfly, flow regulatory, manual and actuated valves and steam traps. Applications include isolating, securing and regulating thermal oil, feed water, hot and cold fluids, vapor, chemicals, gases and steam. Steam traps include ball float, bimetallic, thermostatic and thermodynamic. Control valves available with electric and pneumatic actuators. Safety valves available in full-stroke and normal versions. Materials include stainless, cast, and forged steel, and cast iron. Actuators include diaphragm, electric, pneumatic and manual. Valve applications include car manufacturing, ships, chemicals, food processing, industrial installation, powerstations, fuel/gas purification plant, gas supply, heating, cooling, freezing, and steam systems, and processing technology. Meets ANSI and European pressure ratings.

ARI products are in service around the globe. Whether it is manufacturing cars, ships, chemicals, food processing or heating technology, you will find ARI where any fluid, liquid, gas or vapor needs to be isolated, secured or regulated. As a perennial member of more than 30 representatives on all continents around the globe, we can provide you with the advantages of a reliable partnership – wherever you are.

ari safety valve manual factory

The ARI SAFE safety relief valves design according to EN ISO412-1, TRD 421 and AD2000-A2, Tested according to TUV.SV.-663.D/G/F are an economical and high capacity safety relief valve for the protection of pressure systems.

Options available upon request include different body configurations e.g. closed lifting device, stainless steel bellows, changeover valves, soft sealing discs, proximity switches and special flange drillings.

If you are not sure of the size, you require for your process please do not hesitate to get in contact with our Technical Sales team who will be able to size the correct valve for your process.

ari safety valve manual factory

The primary purpose of a safety valve is to protect life, property and the environment. Safety valves are designed to open and release excess pressure from vessels or equipment and then close again.

The function of safety valves differs depending on the load or main type of the valve. The main types of safety valves are spring-loaded, weight-loaded and controlled safety valves.

Regardless of the type or load, safety valves are set to a specific set pressure at which the medium is discharged in a controlled manner, thus preventing overpressure of the equipment. In dependence of several parameters such as the contained medium, the set pressure is individual for each safety application.

ari safety valve manual factory

Well-known companies worldwide rely on LESER safety valves. With its sole focus on overpressure protection, the safety valve specialist LESER is one of the international market leaders.

ari safety valve manual factory

From the raw water intake to the filtration plant to the finished waster distribution and storage system, GA Industries valves have been providing dependable service in large and small water systems. GA Industries pump control, check and relief valves mitigate damaging pressure surges and eliminate slam and bang that can result from the operation of water pumps.

Air trapped in water pipelines can reduce system efficiency and exacerbate pressure surges. Our wide range of automatic air valves ensures we have the right valve to maintain an air free system.

And when it’s necessary to isolate a pump, process or section of pipeline, you can depend on GA Industries butterfly valves for reliable flow shutoff.

ari safety valve manual factory

The 50 Series Pressure Relief Valve is designed to maintain constant upstream pressure within close limits. In operation, the valve is actuated by line pressure through a pilot control system, opening fast to maintain steady line pressure but closing gradually to prevent surges. In addition to surge relief, this valve can be used for pressure relief, pressure sustaining, back pressure or unloading functions in a by-pass system.