mud pump valve seat failure pricelist
Customers said they wanted long-lasting, easy-to-use valves and seats, and we delivered. Made from domestically sourced steel, GD Energy Products valves feature a two-piece friction-welded design, proprietary bonded inserts, and innovative geometry to deliver significantly longer life. GD Energy Products’ field proven Valves & Seats meet API Standard, and come with our “Ready Inventory” promise that we’ll have it in stock, when you need it.
Our full-open valves and seats are designed for use in GD Energy Products PZ, F-Series, and National 12P lines of triplex drilling pumps. This gives you options to use these parts across your whole fleet of pumps.
Mud Pump Valve & Seat are made of premium alloy steel through one-piece forging and carburizing treatment processes, thereby ensuring high intensity. In addition, the precise calculation is performed and CNC machining is conducted for the dimensional matching of the valve seat and valve body working angles to enhance the service life of the valve body and valve seat. Our valve products are able to work smoothly in normal mining and digging conditions for over 400 hours.
The pump supply line from the tank should be plumbed from the opposite side of the tank than where the bypass return is located. This will minimize air bubbles caused by agitation being drawn into the pump
The most common cause for low performance is worn nozzles. Pumptec recommends that nozzles made from hard materials, not brass, should be used with our pumps. The erosion resulting from high-pressure water is powerful and will increase nozzle size, which will result in lower pressure over time.
As the pump operates, the valves can begin to degrade from exposure to chemicals, heat, cavitation, and abrasives. The small pits in a valve disc or seat will allow small amounts of fluid to leak during each compression stroke and result in less flow going out the nozzle. A preventative maintenance schedule needs to be followed, especially when using harsh or abrasive chemicals.
The primary causes of water leakage are worn seals. Causes of worn seals include wear over time, lack of proper maintenance, abrasive fluids and excessive heat. It is important to monitor pump systems to determine causes of wear and fix them. Pumptec’s seal designs will reveal worn seals in the form of drips below the pump. The leakage would need to be substantial to noticeably affect performance. To prevent seal damage, avoid:
Most Pumptec pumps have stainless steel plungers standard. After extended use or pumping abrasive fluids, the plungers can become grooved, damaging the seal. Plungers with grooving are not reusable and need to be replaced. Pumptec packages plungers and seals together in kits because they should be replaced at the same time.
When excessively high temperature fluids are run through the pump, the seals and elastomers can become deformed and fail. Proper care must be taken to not exceed 140°F fluid temperature in the pump at any time, including idle time.
Pinched hoses and clogged filters will starve the pump of fluid and damage seals as a result of excessive vacuum. Operating the pump without any fluid can increase seal temperature and damage seals. Be sure you always have adequate amounts of fluid available to the pump.
We are a leading Manufacturer of Mud Pump Spare, Duplex Mud Pump Parts, Mud Pump Valve Guide And Spring, SS Gland Flange, Mud Pump Spanner And Puller and Pinion Gear from Mehsana, India.
With great zeal and enthusiasm, our quality certified entity is successfully committed in manufacturing, exporting and supplying optimum quality range of Mud Pump Valve Guide And Spring.Our highly experienced team of professionals manufacture these products with the use of premium grade raw materials. Especially used in mud pumps for controlling the flow of liquids, the offered products are made available in different sizes and finishes. Also, checked by quality experts on various aspects, the provided Mud Pump Valve Guide AndMud Pump ValveSpringat reasonable prices from us.
We are a quality conscious enterprise, successfully engaged in manufacturing, exporting and supplying the best grade of Mud Pump Spanner And Puller.The offered puller is manufactured at our premises with the use of supreme grade raw materials as per international quality standards. The provided spanner with puller is widely used for installation in mud pumps in order to ensure its smooth operations. Additionally, we provide this Mud Pump Spanner AndMud PumpPullerat marginal prices to our clients.
A mud pump is a reciprocating piston/plunger pump designed to circulate drilling fluid under high pressure (up to 7,500 psi (52,000 kPa)) down the drill string and back up the annulus. A duplex mud pump is an important part of the equipment used for oil well drilling.
Duplex mud pumps (two piston/plungers) have generally been replaced by the triplex pump, but are still common in developing countries. Two later developments are the hex pump with six vertical pistons/plungers, and various quintuplex’s with five horizontal piston/plungers. The advantages that Duplex mud pumps have over convention triplex pumps is a lower mud noise which assists with better Measurement while drilling and Logging while drilling decoding.
Use duplex mud pumps to make sure that the circulation of the mud being drilled or the supply of liquid reaches the bottom of the well from the mud cleaning system. Despite being older technology than the triplex mud pump, the duplex mud pumps can use either electricity or diesel, and maintenance is easy due to their binocular floating seals and safety valves.
A mud pump is composed of many parts including mud pump liner, mud pump piston, modules, hydraulic seat pullers, and other parts. Parts of a mud pump:housing itself
Duplex pumps are used to provide a secondary means of fuel transfer in the event of a failure of the primary pump. Each pump in a duplex set is sized to meet the full flow requirements of the system. Pump controllers can be set for any of the following common operating modes:Lead / Lag (Primary / Secondary): The lead (primary) pump is selected by the user and the lag (secondary pump operates when a failure of the primary pump is detected.
Alternating: Operates per Lead / Lag (Primary / Secondary) except that the operating pump and lead / lag status alternate on consecutive starts. A variation is to alternate the pumps based on the operating time (hour meter) of the lead pump.