pto hydraulic pump for john deere 7200 planter quotation
I bought a 7200 6RN that I want to put a PTO pump on. Pulling the planter with a 30 series John Deere and don"t want to spend the money on Power Beyond or worry about burning out the hydraulics. I bought a pump off an 800 IH planter. Has anyone done this? Does it work? Anything special I need to do. Can these pumps be rebuilt if it doesn"t work? Thanks a lot guys.
I have a JD 7200 vacuum planter. The question is can I run this planter with a 7045? The manual says that my 7050 has open-center hydros, but the 7045 has closed center. The book said I need closed-center hydros to run the planter. It does not have the pto pump.
I"m not an authority here but sure they have same hyd system. I think the hyd system will be marginal if even work on that planter.Brother in law said his 4840 Deere didn"t have enough hydraulics for one of those.Deere lists a whole hyd system add on for pto pump. $$$$$$$ He said they rented a 12-30 7200 vac and it was terrible slow lifting. I was looking at one last year for my 8070 and wasn"t liking info I was getting from Deere dealer on hydraulic setup. I really don"t know the answer but you may find out the hard way?
Is there NO other way to run these planters? I did not realize a 7200 was a vac planter, I thought they were a "slightly"updated 7000. Apparently more updated than I thought,LOL!
I have converted two 7200 planters over to using a 1000 rpm CIH pump and put a cooler in the return line to keep the oil cool. I also put a jumper line from the high pressure side to the low pressure side with a needle valve to regulate the oil flow to the vacuum blower for vacuum control. Works very well.
I don"t know how the two tractors would compare but I ran a 12 row 1760 JD vac planter with a deere 4440 and had plenty of hydraulics for raise and lower, markers, and meters. This was using just the tractor hydraulics with no external pump and didn"t need high RPMs on endrows.
May need to look into a case drain on the return. Try calling JO Harris in Illinois they handle a huge number of planters might have ideas on a PTO pump.
If I remember correctly, the vac blower on the JD planters only uses 3 or 4 gallon a minute (at maximum speed), I don"t know if you have one or two blowers (4 or 8 GPM max) since they potentially could have been setup either way. Works best if you have a flow control handle under the seat and use that remote to run the vac fan and adjust your vac level that way. As for a PTO pump setup, one off a White planter would work too. 7200 could have either a vac meter or a finger meter system. If running the fan off the tractor hydraulics though, make sure to move the control lever to float to stop the fan if you don"t have an overrunning circuit to allow the fan to stop. Otherwise it will snap the shaft off on the fan motor with it locking in the hold position. Another way to plumb it, if it doesn"t have the overrunning feature, is to put a check valve from the pressure line to the return line that allows oil to the pressure line, but not to the return line. Then when you put the lever in hold, the check valve will open and allow the fan to coast to a stop. Most likely the fan has the overrunning valve installed if previously powered from the tractor, but doesn"t hurt to mention it to avoid an expensive oops.Edited by wayne IA - 13 Dec 2017 at 8:48pm
7050 has the same hydraulic system as the 7045. Closed Center Pressure and flow compensated. I think I"ve read on here before that the PTO pump is still preferred as running the tractor hydraulic pump constantly is hard on it. I could be wrong about that last part but I"m not wrong on what type of hydraulic system a 7050 has.
Any 7 or 8 thousand series tractor should run it. Having a hydraulic oil cooler on the tractor is best. Make sure stand by pressure and high pressure is up to high end of spec. Darrel
No, a 7200 could be either vac or finger pickup, just depends how it was ordered. You can run a vac planter with a PTO pump if the tractor doesn"t have the hydraulic capacity. Imo the vac units are a lot simpler setup then a finger pickup unit.
PTO-driven hydraulic vacuum pumpThis attachment allows using the vacuum seed meter system pump with tractors having an open-center hydraulic system and/or a 540-rpm or 1000-rpm PTO.
Flat seed disks such as edible bean and sweet corn require high levels of vacuum. These disks require a dual vacuum motor configuration on planters over 8 rows. The 1000-rpm PTO pump is not adequate for this application.
You"d really need to get down to the flow/pressure specs needed for your planter and compare them to the IH planter"s you"re looking at robbing if you go that route. They"d need to be within the same range.
I guess the question I"d be asking or wondering about is why you wouldn"t just run it off the SCV"s on a new tractor if you"re doing that now. Most 1/2" valves flow about 16 GPM per pair. The Ford shouldn"t have any problem doing that if the planter is using most of it"s flow. The problem you get into on the open center Ford"s is when you try to choke them down and they have to dump a significant portion of their pump flow at pressure across the unloading valve...
You might also want to double check and see if the 7740 isn"t a CCLS tractor to start with... Many, if not most around here were. If it"s an "SLE" with the 16x16 transmission, or even a 24x24, it should be CCLS. A 12x12 or the 8x2 would be open center. Those are "SL" and "S" models. The "SLE" will have no problem doing what you want in running the planter on the SCV.
Another option I"d look at would be PTO driving the fan. The planter I use is set up like that and just geared to run the tractor at mid-speed on the PTO. Something to think about...
This website is using a security service to protect itself from online attacks. The action you just performed triggered the security solution. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data.
Protect your equipment with an Ag Guard Extended Service Plan provided by Machinery Scope. Powertrain, Hydraulics, and/or Platform coverage options available for up to 3 additional years. Machinery Scope will follow up with your personalized quote.
By submitting this form, you agree to allow Machinery Pete to send you communications via email. You can unsubscribe at any time by clicking the unsubscribe link in the footer of any of our email communications.
This website is using a security service to protect itself from online attacks. The action you just performed triggered the security solution. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data.
This website is using a security service to protect itself from online attacks. The action you just performed triggered the security solution. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data.
This website is using a security service to protect itself from online attacks. The action you just performed triggered the security solution. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data.