vickers hydraulic pump cross reference brands
Innovation, quality and reliability are the core values of our company. These principles today more than ever form the basis of our success as an internationally active mid-size company for Vickers Hydraulic Pump Cross Reference, Concrete Pump Truck Operator Jobs, Hydraulic Gear Pump Parts, Vickers Vane Pump Cartridge Kits,Hydraulic Pump Unloading. We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits. The product will supply to all over the world, such as Europe, America, Australia,Gabon, Ireland,Ethiopia, Johor.We focus on providing service for our clients as a key element in strengthening our long-term relationships. Our continual availability of high grade products in combination with our excellent pre-sale and after-sales service ensures strong competitiveness in an increasingly globalized market.
The market today is flooded with various types of hydraulic pump cross reference guides. With different makes and models, it is critical to find the right cross reference guide that will work with your hydraulic pump style, size and type. At HPCROSSREF.com, we offer a comprehensive catalog of cross reference guides that will fit a variety of different hydraulic pump styles, sizes and types. Our catalog includes over 50 cross references for high performance pumps for lifts, cranes and other hydraulics power applications.
The following is a list of some of the most common Cessna hydraulic pumps. If you have an older model, chances are it won’t be listed here. However, if you have an older model, it’s likely that your hydraulic pump will be similar in size to one of the newer models listed below.
Hydraulic pumps from Parker are used on many different applications, including construction equipment, heavy machinery, and agricultural equipment. If you need to replace your Parker pump, we have a wide selection of hydraulic pumps for you to choose from. Our hydraulic pumps are produced to meet or exceed OEM specifications and performance. We offer parker hydraulic pump cross reference charts to help you get the right part for your machine so you can get back to work as soon as possible!
1PV2V418/20RW12VW100ARexrothPumpPVM020ER17DS01AAH00200000A0AVickersRR HAS A 4 BOLT MOUNT, VICKERS IS 2 BOLT, VICKERS CONTROL OPTION WILL REQUIRE ADDED VALVESTO ACHIEVE THE DUAL STAGE ELECTRONICALLY CONTROLLED
4WE10D2X/OFA120/60NDZALVRexrothValveDG4V52NVMU6EK620VickersRr Dzal Is A Special Connector That Screws Into The Conduit Cavity Of The Valve Body, Vickers Does Not Offer That Type Of Connection, Suggest Using The Din Type Coils And Connector
4WE10E33/CW110RNG24K4RexrothValveDG4V52CHJVMU12DJ620VickersRr R Is For Rectified 110Vac To Dc, Vickers U12 Is For Din Connector With Rectifier Dj Is For 98Vdc Which Is The Accepted Rectified Dc Voltage For 110Vac
4WE10EB3X/CG24NK4QBG24RexrothValveDG4V52BLJHVMS6UH620VickersRr Uses A Contact Type Spool Position Monitoring Switch Vickers Offers An Lvdt Type In The Dg4V-5 Series
4WE10G11/LW110RNZ55VRexrothValveDG4V58CJVMU12DJ620VickersRr R Is For Rectified 110Vac To Dc, Vickers U12 Is For Din Connector With Rectifier Dj Is For 98Vdc Which Is The Recommended Dc Voltage To Accept Rectified 110Vac
4WE10G32/CW110RN9Z55L/ARexrothValveDG4V58CJVMU11DJ620VickersRr R Is For Rectified 110Vac To Dc, Vickers U11 Is For Din Connector With Rectifier And Lights Dj Is For 98Vdc Which Is The Recommended Dc Voltage To Accept Rectified 110Vac
4WE10GB3X/CW110N9K4RexrothValveDG4V58BVMUEK620VickersVickers Equal Does Not Offer Dual Frequency 110/120Vac Like Rr, Ek Is 120Vac60Hz Single Frequency
4WE10JB3X/CG96N9K4QBG24RexrothValveDG4V56BJVMS6UDJ620VickersRr Qbg24 Is Contact Style Spool Monitoring Switch Vickers Dg4V-5 Series Only Offers Lvdt Type
4WE10R31/LW12060NDALVRexrothValveF3DG4V40152CVMWLB510VickersNormally Rr L Is For Air Gap, Vickers Air Gap Does Not Have Pressure Rating Of The Rexroth
4WE6D52/AW12060NK4QBG24RexrothValveDG4V32AHVMS6U1B660VickersRexroth Qbg24 Is A N.O./N.C. Contact Type Spool Position Switch Only Vickers Spool Position Switch With The Din Coils Is The S6 Version, Lvdt Type.
4WEH16L6X/6EW110N9ES2Z5L/10RexrothValveDG5V73C2VMU6B630VickersVickers Spool Transition Is Slightly Different When B Is Energized Transition Is Ports Blocked, Rr Is Ports Blocked With Restricted Bleed Off For B To T
4WEH22H7X/6AW110N9ETSDAP4.5RexrothValveDG5V8H0C2TSVMFWB10VickersRr S Is For Meter-In Pilot Chokes, We Only Offer Meter-Out Pilot Chokes, Code Option 2. Rr P4.5 Is For 65 Psi P Port Check, We Have 75 Psi, Code Option S.
4WRAB6W2511/G24N9DK25VRRexrothValveKDG4V333C20NHMU1H760VickersRr Spool Is Rated 25 L/Min, Vickers Is Rated 20 L/Min, Also We Do Not Offer The 5 Pin Connector In The Hp Kdg4V3 Must Use Vickers Electronics
4WRAE10WA602X/G24N9K31A1RexrothValveKBTG4V533B70NZM1PE7H710EN56VICKERSRR SPOOL RATED 60 L/MIN AT 10 BAR DROP, VICKERS IS 70 L/MIN, RR HAS MANUAL OVERRIDES, VICKERS DOES NOT
4WRD10V10040/10L2Z9/VRexrothValveKHDG5V55C85NEXVMU1H120VickersRr Has Servo Valve As Pilot, Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 100 L/Min Vickers Is Rated 85 L/Min
4WRD10V5040/10L2Z9/VRexrothValveKHDG5V55C85NEXVMU1H120VickersRr Has Servo Valve As Pilot, Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 50 L/Min Vickers Is Rated 85 L/Min
4WRD16V1003X/10L2TZ8MRexrothValveKHDG5V75C200NEXVMU1H120VickersRr Has Servo Valve As Pilot, Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 100 L/Min Vickers Is Rated 200 L/Min
4WRDE10V100L51/6L24Z9/M202RexrothValveKBHDG5V55C85NEXM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 100 L/Min Vickers Is Rated 85 L/Min
4WRDE10V50P5X/6L24ETK9/MR280RexrothValveKBHDG5V55C85NTM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 50 L/Min Vickers Is Rated 85 L/Min
4WRDE16E125L51/6L24TZ9RexrothValveKBHDG5V72C200NEXTM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 125 L/Min Vickers Is Rated 200 L/Min
4WRDE16V1125L5X/6L24ETK9VRexrothValveKBHDG5V75C200N115TM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 125/63 L/Min Vickers Is Rated 200/115 L/Min
4WRDE16V125L51/6L24Z9/M202RexrothValveKBHDG5V75C200NEXM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 125 L/Min Vickers Is Rated 200 L/Min
4WRDE16W152.8P5X/6L24Z9VRRexrothValveKBHDG5V733C160NEXM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 200 L/Min Vickers Is Rated 160 L/Min
4WRE10E2641X/24Z4VRexrothValveKFDG4V52C50N25ZVMU1H720VickersE2 Rr Has Different Flow Division, Rr Q/Max Is For P To B, Vickers Is P To A Also Rr Spool Rated To 64/32 L/Min Vickers Is Rated 50/25 L/Min Must Use Vickers Electronics
4WRE6E081X/24K4MRexrothValveKFDG4V32C13NZVMUH720VickersMust Use Vickers Electronics For Guaranteed Performance Rr Spool Is Rated 8 L/Min, Closest Vickers Is 13 L/Min
4WRE6E081X/24Z4MRexrothValveKFDG4V32C13NZVMU1H720VickersMust Use Vickers Electronics For Guaranteed Performance Rr Spool Is Rated 8 L/Min, Closest Vickers Is 13 L/Min
4WRE6EA3212/24Z4/MRexrothValveKFTG4V32B20NZVMU1H720VickersRr Spool Is Rated 32 L/Min, Vickers Is Rated 20 L/Min Must Use Vickers Electronics For Guaranteed Performance
4WREE10W1752X/G24/K31/A1VRexrothValveKBFDG4V533C50N25ZM1PE7H711VickersRr Spool Is Rated Is 75/38 L/Min, Vickers Is Rated 50/25 L/Min, Will Handle 75/38 But With Increased Pressure Drop
4WREE10W1752X/G24/K31/F1VRexrothValveKBFDG4V533C50N25ZM2PE7H711VickersRr Spool Is Rated Is 75/38 L/Min, Vickers Is Rated 50/25 L/Min, Will Handle 75/38 But With Increased Pressure Drop
4WREE6EA3222G24K31A1VRexrothValveKBFTG4V32B20NZM1PE7H711VickersRr Spool Is Rated To 32 L/Min, Vickers Is 20 L/Min But Can Go To 32 L/Min With Increased Delta P
4WRLE16EZ180SJ3XG24K0A1M OLD BOSCH 0811404305RexrothValveKBHDG5V72C200NEXM1PE7H411VickersBosch Valve Has Pressure Tapping Ports For Better Delta P Signal For Load Sensing, Review Application
4WRLE16WZ180SJ3X/G24K0/A1M/OLD BOSCH 0811404307RexrothValveKBHDG5V733C160NEXM1PE7H411VickersClosest Vickers, The Rr Has Pressure Tapping Ports To Each End Of The Spool For Detecting Delta P For Hydrostatic Function, Vickers Does Not Offer This. Also The Rr Spool Is Rated To 180 L/Min Vickers Is 160 L/Min
4WRLE25WZ350SJ3X/G24K0/A1M/OLD BOSCH 0811404456RexrothValveKBHDG5V833C375NEXM1PE7H411VickersClosest Vickers, The Rr Has Pressure Tapping Ports To Each End Of The Spool For Detecting Delta P For Hydrostatic Function, Vickers Does Not Offer This. Also The Rr Spool Is Rated To 350 L/Min Vickers Is 375 L/Min
4WRTE25Q23502X/6BG24Z9/M/RRexrothValveKBHDG5V833C375NEXM1PH7H411VickersRr Spool Is Rated 350 L/Min Vickers Is 375 L/Min Rr Spool Transitions Are Different, But Center And Shifted Functions Are The Same
4WRTE25Q2350P31/6G24Z31RexrothValveKBHDG5V833C375NEXM1PH7H411VickersRr Spool Is Rated 350 L/Min Vickers Is 375 L/Min Rr P Is Linear Flow With Fine Control Basically The Initial 25 % Of Spool Shift Has A More Deliberate Flow Rise Rr Spool Transitions Are Different, But Center And Shifted Functions Are The Same
4WRTE25Q2350P4X/6EG24K31A5MRexrothValveKBHDG5V833C375NEXM1PH7H411VickersRr Spool Is Rated 350L/Min, Vickers Is 375L/Min Rr P Is Linear Flow With Fine Control Basically The Initial 25% Of Spool Shift Has A More Deliberate Flow Rise Rr Spool Transitions Are Different, But Center And Shifted Functions Are The Same
4WRZ10W1854X/6A24N9EZ4D3MRexrothValveKDG5V533C60N40XVMUH110VickersRr Spool Is Rated 85/42 L/Min Vickers Is Rated 60/40 L/Min Must Use Vickers Electroincs
4WRZ16E110031/6A24NZ4D2RexrothValveKDG5V72C180N100EXVMUH110VickersRr Spool Is Rated 100/50 L/Min Vickers Is Rated 180/100 L/Min Must Use Vickers Electronics
4WRZ16E15050/6A12N9Z4D3MRexrothValveKDG5V72C180NEXVMUG110VickersMust Use Vickers Electroincs, With The 12Vdc Coils Only Option Is The Ehhamp712D20 Power Plug
4WRZ16W115060/6A24N9EK4/D3MRexrothValveKDG5V733C130N65XVMUH110VickersRr Spool Is Rated 150/75 L/Min Vickers Is 130/65 L/Min Must Use Vickers Electronics
4WRZ32W252050/6A24N9EZ4RexrothValveKDG5V1033C550N310HMUH110VickersRr Spool Is Rated 520/260 L/Min Vickers Is 550/310 L/Min Must Use Vickers Electronics
4WS2EM1045/5B2ET315Z8BMRexrothValveSM420(2.5)9300/3050S135VickersRr Is Rated 5 L/Min, Vickers Has 3,8 Or 9 L/Min S135 Means Matches Rexroth Wiring And Underlap Option
4WS2EM1045/5B2T315Z8DBRexrothValveSM420(2.5)9300/3050S46 + SM4A52050VickersS46 = REXROTH WIRING, WILL NEED TO ACTIVATE 5TH PORT FOR EXTERNAL PILOT SUPPLY, CONTACT TECHNICAL SUPPORT FOR INSTRUCTIONS
4WS2EM1045/5B2T315Z8DBRexrothValveSM420(2.5)9300/3050S46+SM4A52050VickersS46 = Rexroth Wiring, Will Need To Activate 5Th Port For External Pilot Supply, Contact Technical Support For Instructions
4WS2EM611/20F12ET315Z17EMRexrothValveSM410(5)1980/5010S46 + SM4A31010VickersRR IS RATED 315 BAR, VICKERS SM410 IS 3000 PSI S46 MEANS MATCHES REXROTH WIRING
4WS2EM611/20F12ET315Z17EMRexrothValveSM410(5)1980/5010S46+SM4A31010VickersRr Is Rated 315 Bar, Vickers Sm410 Is 3000 Psi S46 Means Matches Rexroth Wiring
A10VSO10DR/52RPKC64N00RexrothPumpPVM018ER02AE01ASA28000000A0AVickersRR IS A 10CC/REV PUMP, CLOSEST VICKERS IS AN 18CC/REV, WITH MAX VOLUME ADJ OPTION CAN SET VICKERS DOWN TO 10CC
A10VSO140 DFR/31RPPB12K02RexrothPumpPVM141ER19KS02AAB2311000CA0A, CLOSEST VICKERSVickersshaft 40mm diameter versus 45mm for RR, pilot diameter 160mm versus 180mm, flange ports are SAE diameter but with metric threads, Vickers SAE diameter flanges with inch threads.
A10VSO140 DFR/31RPPB12K02RexrothPumpPVM141ER19KS02AAB2311000CA0A,CLOSESTVICKERSVickersShaft 40Mm Diameter Versus 45Mm For Rr, Pilot Diameter 160Mm Versus 180Mm, Flange Ports Are Sae Diameter But With Metric Threads, Vickers Sae Diameter Flanges With Inch Threads.
AA10VSO18DRG/31RPKC62N00RexrothPumpPVM018ER02AS02AAC28110000A0AVickersNEED TO OBTAIN SPECIAL PLUMBING INSTRUCTIONS, ONLY WAY TO ACHIEVE THE CONTROL EQUAL TO THE RR DRG
AA10VSO45DFR31RVKC62K05RexrothPumpPVM045ER06CS02AAB2811000DA0AVickersREXROTH HAS SAE BB STRAIGHT KEY THRU DRIVE VICKERS ONLY OFFERS SPLINE THRU-DRIVE SHAFTS CROSS IS WITH AN SAE BB SPLINED OUTPUT SHAFT
AA10VSO71DR31RPKC62K40RexrothPumpPVM074ER09ES02ASA2800000BA0AVickersRR HAS SAE C STRAIGHT DIA OUTPUT SHAFT (K40) VICKERS ONLY OFFERS SPLINE OUTPUT SHAFTS CROSSED TO SAME MOUNT BUT WITH 11 TOOTH SPLINE SHAFT
AA2FM90/61WVQD520RexrothMotorBAF Series is no longer Available. Contact Tech Support.EatonRR SPLINED SHAFT IS 14T, 16/32 DP VICKERS SHAFT IS 13T 8/16 DP
AA4VG180HD1DM132LNSDS2F021DRRexrothPumpHPV210L0S4MH1200L21SAFBFAE0000000AAAEATONOUR INPUT SHAFT IS NOT THE SAME, WE HAVE A 15 TOOTH 8/16 DP, RR HAS 13 TOOTH 8/16 DP
AA4VSO250DR/31RPB1N00RexrothPumpPVXS250M06R0001R01SV0ADF000A0000000000000000010HydroKraftRR PILOT DIA IS 224MM AND SHAFT DIA IS 60MM VICKERS PILOT DIA IS 200MM AND SHAFT DIA 65MM
FESE40CA3X670LK0B1MRexrothValveCVU40EFP1B297031EN107 OR CVU40EFP1B299031VickersEN107 = 40MM CARTRIDGE WITH 700 L/MIN FLOW RATED SPOOL TO MATCH REXROTH IS 670 L/MIN SPOOL, STANDARD CVU-40 IS 900 L/MIN
FESE40CA3X670LK0B1MRexrothValveCVU40EFP1B297031EN107ORCVU40EFP1B299031VickersEn107 = 40Mm Cartridge With 700 L/Min Flow Rated Spool To Match Rexroth Is 670 L/Min Spool, Standard Cvu-40 Is 900 L/Min
H4WEH16U10B6X/11060Z5LQ0G24RexrothValveDG5V731CPCAEZVMU6B630VickersVickers Pca Is The Recommended Option To Replace The Rr Q0G24. Rr Used Two Switches, We Use One To Obtain The Same Result.
HED8OH12/100K14RexrothValveSG307F150 + DGMP3*B10Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.
HED8OH12/100K14RexrothValveSG307F150+DGMP3*B10Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.
HED8OH12/100Z14 SRexrothValveSG307F150 + DGMP3*B10,Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.
HED8OH12/100Z14 SRexrothValveSG307F150+DGMP3*B10,Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.
HED8OH12/200K14RexrothValveSG307F350 + DGMP3*B10Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.
HED8OH12/200K14RexrothValveSG307F350+DGMP3*B10Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.
HED8OH12/50K14RexrothValveSG307F55 + DGMP3*B10Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.
HED8OH12/50K14RexrothValveSG307F55+DGMP3*B10Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.
LC25DB40D7X/RexrothValveCVI25D10H40EN9VickersRr Cracking Pressure Is 4,0 Bar, Vickers Is 3,1 Bar Vickers Rate Gives The Vickers The Best Performancewhen Used With The Relief Covernote
LC32DB20E7X/RexrothValveCVI32D10H40EN9VickersRr Cracking Pressure Is 2,0 Bar, Vickers Is 3,1 Barthis Is For The Best Performance When Used Withvickers Pressure Control Coversnote
LC40DB20B7X/RexrothValveCVI40C10FC40EN9VickersRr Cracking Pressure Is 2,0 Bar, Vickers Is 2,35 Barfor The Best Performance With Vickers Pressurerelief Coversnote
LC40DR40E7X/RexrothValveCVI40X240EN9VickersOnly Vickers Insert For Pressure Reducing Functionnot Enough Informaton On The Rr To Completelyvalidate Crossnote
LFA16EWA6X/CA20DQMG24/12RexrothValveCVU16ZSWD3B29M10VickersRr Cracking Pressure Is 2 Bar, Vickers Is 2.5 Bar, Also Rr Has Inch Based Threads. Vickers Only Offer Metric With This Style
LFA25WEB62/12RexrothValveCVCS25D3B2910VickersRexroth Uses Single Solenoid Offset Directionals Where They Direct Oil Specifically To The A Or B Port, The Vickers Uses Double Solenoid And Can Direct To Either A Or B By Which Solenoid It Energizes,
PV717/2530RE01MC016RexrothPumpPVM045ER17DS05AAA1600000AA0AVickersRR HAS 100MM 4 BOLT MOUNT, VICKERS IS 100MM 2 BOLT, OUR THRU DRIVE IS NOT THE SAME, WE HAVE SAE A2 BOLT PAD WITH 9 TOOTH SPLINE SHAFT, RR IS SPECIAL SPLINE AND PAD FOR MOUNTING ANOTHER PV7 PUMP
Z2FS1021X/2QVRexrothValveDGMFN5XA2WB2W30 OR DGMFN5YA2WB2W30VICKERSDGMDN5X - METER-IN, DGMFN5Y - METER-OUT, RR CAN BE EITHER BASED ON ASSEMBLED POSITION
Z2S1013X/V (Z2SRK10)RexrothValveDGMPC5DABKDBAK30VickersRr Is 22 Psi Cracking Psi, Vickers Is 15 Psi, The Z2Srk Is Fixed Cracking Pressure & Rated For 21 Gpm, The Z2S Is 32 Gpm And Has Options For Different Cracking Pressures
The John S Barnes hydraulic pump seen on the market are old-fashioned hydraulic pumps before 1997, so many people can’t find effective documents and videos about the John S Barnes hydraulic pump. In 1997, the John Barnes S hydraulic pump was officially renamed. For Haldex Barnes Hydraulics, John S Barnes hydraulic pump identification is Haldex Barnes Hydraulics identification, then we teach you how to quickly identify John S Barnes hydraulic pump (Haldex Barnes Hydraulics),But we still provide OEM customized john s barnes hydraulic pump cross reference parts!
Permco (Fluid Permco) has been a leading manufacturer of hydraulic pumps and parts since 1975. With a large selection of high quality products, Permco can meet all your hydraulic pump needs. Permco offers a wide range of products including: Piston Pumps, Gear Pumps, Plunger Pumps, Rotary Vane Pumps and more… We carry both new and used parts for all applications.
The following cross reference table is for the Webster L-Pump, which is a popular pump used in a variety of applications. We have compiled this list to help you find the exact replacement part you need.
We have a large selection of Vickers Hydraulic Pumps. We can provide you with the correct Vickers Hydraulic Pump for your application, as well as help you to find the right replacement part for your existing unit. Our customer service team is ready to assist you in finding the correct part for your application.
We have a large selection of Vickers Hydraulic Pumps in stock. We can provide you with the correct Vickers Hydraulic Pump for your application, as well as help you to find the right replacement part for your existing unit. Our customer service team is ready to assist you in finding the correct part for your application.
1PV2V418/20RW12VW100ARexrothPumpPVM020ER17DS01AAH00200000A0AVickersRR HAS A 4 BOLT MOUNT, VICKERS IS 2 BOLT, VICKERS CONTROL OPTION WILL REQUIRE ADDED VALVESTO ACHIEVE THE DUAL STAGE ELECTRONICALLY CONTROLLED
4WE10D2X/OFA120/60NDZALVRexrothValveDG4V52NVMU6EK620VickersRr Dzal Is A Special Connector That Screws Into The Conduit Cavity Of The Valve Body, Vickers Does Not Offer That Type Of Connection, Suggest Using The Din Type Coils And Connector
4WE10E33/CW110RNG24K4RexrothValveDG4V52CHJVMU12DJ620VickersRr R Is For Rectified 110Vac To Dc, Vickers U12 Is For Din Connector With Rectifier Dj Is For 98Vdc Which Is The Accepted Rectified Dc Voltage For 110Vac
4WE10EB3X/CG24NK4QBG24RexrothValveDG4V52BLJHVMS6UH620VickersRr Uses A Contact Type Spool Position Monitoring Switch Vickers Offers An Lvdt Type In The Dg4V-5 Series
4WE10G11/LW110RNZ55VRexrothValveDG4V58CJVMU12DJ620VickersRr R Is For Rectified 110Vac To Dc, Vickers U12 Is For Din Connector With Rectifier Dj Is For 98Vdc Which Is The Recommended Dc Voltage To Accept Rectified 110Vac
4WE10G32/CW110RN9Z55L/ARexrothValveDG4V58CJVMU11DJ620VickersRr R Is For Rectified 110Vac To Dc, Vickers U11 Is For Din Connector With Rectifier And Lights Dj Is For 98Vdc Which Is The Recommended Dc Voltage To Accept Rectified 110Vac
4WE10GB3X/CW110N9K4RexrothValveDG4V58BVMUEK620VickersVickers Equal Does Not Offer Dual Frequency 110/120Vac Like Rr, Ek Is 120Vac60Hz Single Frequency
4WE10JB3X/CG96N9K4QBG24RexrothValveDG4V56BJVMS6UDJ620VickersRr Qbg24 Is Contact Style Spool Monitoring Switch Vickers Dg4V-5 Series Only Offers Lvdt Type
4WE10R31/LW12060NDALVRexrothValveF3DG4V40152CVMWLB510VickersNormally Rr L Is For Air Gap, Vickers Air Gap Does Not Have Pressure Rating Of The Rexroth
4WE6D52/AW12060NK4QBG24RexrothValveDG4V32AHVMS6U1B660VickersRexroth Qbg24 Is A N.O./N.C. Contact Type Spool Position Switch Only Vickers Spool Position Switch With The Din Coils Is The S6 Version, Lvdt Type.
4WEH16L6X/6EW110N9ES2Z5L/10RexrothValveDG5V73C2VMU6B630VickersVickers Spool Transition Is Slightly Different When B Is Energized Transition Is Ports Blocked, Rr Is Ports Blocked With Restricted Bleed Off For B To T
4WEH22H7X/6AW110N9ETSDAP4.5RexrothValveDG5V8H0C2TSVMFWB10VickersRr S Is For Meter-In Pilot Chokes, We Only Offer Meter-Out Pilot Chokes, Code Option 2. Rr P4.5 Is For 65 Psi P Port Check, We Have 75 Psi, Code Option S.
4WRAB6W2511/G24N9DK25VRRexrothValveKDG4V333C20NHMU1H760VickersRr Spool Is Rated 25 L/Min, Vickers Is Rated 20 L/Min, Also We Do Not Offer The 5 Pin Connector In The Hp Kdg4V3 Must Use Vickers Electronics
4WRAE10WA602X/G24N9K31A1RexrothValveKBTG4V533B70NZM1PE7H710EN56VICKERSRR SPOOL RATED 60 L/MIN AT 10 BAR DROP, VICKERS IS 70 L/MIN, RR HAS MANUAL OVERRIDES, VICKERS DOES NOT
4WRD10V10040/10L2Z9/VRexrothValveKHDG5V55C85NEXVMU1H120VickersRr Has Servo Valve As Pilot, Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 100 L/Min Vickers Is Rated 85 L/Min
4WRD10V5040/10L2Z9/VRexrothValveKHDG5V55C85NEXVMU1H120VickersRr Has Servo Valve As Pilot, Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 50 L/Min Vickers Is Rated 85 L/Min
4WRD16V1003X/10L2TZ8MRexrothValveKHDG5V75C200NEXVMU1H120VickersRr Has Servo Valve As Pilot, Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 100 L/Min Vickers Is Rated 200 L/Min
4WRDE10V100L51/6L24Z9/M202RexrothValveKBHDG5V55C85NEXM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 100 L/Min Vickers Is Rated 85 L/Min
4WRDE10V50P5X/6L24ETK9/MR280RexrothValveKBHDG5V55C85NTM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 50 L/Min Vickers Is Rated 85 L/Min
4WRDE16E125L51/6L24TZ9RexrothValveKBHDG5V72C200NEXTM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 125 L/Min Vickers Is Rated 200 L/Min
4WRDE16V1125L5X/6L24ETK9VRexrothValveKBHDG5V75C200N115TM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 125/63 L/Min Vickers Is Rated 200/115 L/Min
4WRDE16V125L51/6L24Z9/M202RexrothValveKBHDG5V75C200NEXM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 125 L/Min Vickers Is Rated 200 L/Min
4WRDE16W152.8P5X/6L24Z9VRRexrothValveKBHDG5V733C160NEXM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 200 L/Min Vickers Is Rated 160 L/Min
4WRE10E2641X/24Z4VRexrothValveKFDG4V52C50N25ZVMU1H720VickersE2 Rr Has Different Flow Division, Rr Q/Max Is For P To B, Vickers Is P To A Also Rr Spool Rated To 64/32 L/Min Vickers Is Rated 50/25 L/Min Must Use Vickers Electronics
4WRE6E081X/24K4MRexrothValveKFDG4V32C13NZVMUH720VickersMust Use Vickers Electronics For Guaranteed Performance Rr Spool Is Rated 8 L/Min, Closest Vickers Is 13 L/Min
4WRE6E081X/24Z4MRexrothValveKFDG4V32C13NZVMU1H720VickersMust Use Vickers Electronics For Guaranteed Performance Rr Spool Is Rated 8 L/Min, Closest Vickers Is 13 L/Min
4WRE6EA3212/24Z4/MRexrothValveKFTG4V32B20NZVMU1H720VickersRr Spool Is Rated 32 L/Min, Vickers Is Rated 20 L/Min Must Use Vickers Electronics For Guaranteed Performance
4WREE10W1752X/G24/K31/A1VRexrothValveKBFDG4V533C50N25ZM1PE7H711VickersRr Spool Is Rated Is 75/38 L/Min, Vickers Is Rated 50/25 L/Min, Will Handle 75/38 But With Increased Pressure Drop
4WREE10W1752X/G24/K31/F1VRexrothValveKBFDG4V533C50N25ZM2PE7H711VickersRr Spool Is Rated Is 75/38 L/Min, Vickers Is Rated 50/25 L/Min, Will Handle 75/38 But With Increased Pressure Drop
4WREE6EA3222G24K31A1VRexrothValveKBFTG4V32B20NZM1PE7H711VickersRr Spool Is Rated To 32 L/Min, Vickers Is 20 L/Min But Can Go To 32 L/Min With Increased Delta P
4WRLE16EZ180SJ3XG24K0A1M OLD BOSCH 0811404305RexrothValveKBHDG5V72C200NEXM1PE7H411VickersBosch Valve Has Pressure Tapping Ports For Better Delta P Signal For Load Sensing, Review Application
4WRLE16WZ180SJ3X/G24K0/A1M/OLD BOSCH 0811404307RexrothValveKBHDG5V733C160NEXM1PE7H411VickersClosest Vickers, The Rr Has Pressure Tapping Ports To Each End Of The Spool For Detecting Delta P For Hydrostatic Function, Vickers Does Not Offer This. Also The Rr Spool Is Rated To 180 L/Min Vickers Is 160 L/Min
4WRLE25WZ350SJ3X/G24K0/A1M/OLD BOSCH 0811404456RexrothValveKBHDG5V833C375NEXM1PE7H411VickersClosest Vickers, The Rr Has Pressure Tapping Ports To Each End Of The Spool For Detecting Delta P For Hydrostatic Function, Vickers Does Not Offer This. Also The Rr Spool Is Rated To 350 L/Min Vickers Is 375 L/Min
4WRTE25Q23502X/6BG24Z9/M/RRexrothValveKBHDG5V833C375NEXM1PH7H411VickersRr Spool Is Rated 350 L/Min Vickers Is 375 L/Min Rr Spool Transitions Are Different, But Center And Shifted Functions Are The Same
4WRTE25Q2350P31/6G24Z31RexrothValveKBHDG5V833C375NEXM1PH7H411VickersRr Spool Is Rated 350 L/Min Vickers Is 375 L/Min Rr P Is Linear Flow With Fine Control Basically The Initial 25 % Of Spool Shift Has A More Deliberate Flow Rise Rr Spool Transitions Are Different, But Center And Shifted Functions Are The Same
4WRTE25Q2350P4X/6EG24K31A5MRexrothValveKBHDG5V833C375NEXM1PH7H411VickersRr Spool Is Rated 350L/Min, Vickers Is 375L/Min Rr P Is Linear Flow With Fine Control Basically The Initial 25% Of Spool Shift Has A More Deliberate Flow Rise Rr Spool Transitions Are Different, But Center And Shifted Functions Are The Same
4WRZ10W1854X/6A24N9EZ4D3MRexrothValveKDG5V533C60N40XVMUH110VickersRr Spool Is Rated 85/42 L/Min Vickers Is Rated 60/40 L/Min Must Use Vickers Electroincs
4WRZ16E110031/6A24NZ4D2RexrothValveKDG5V72C180N100EXVMUH110VickersRr Spool Is Rated 100/50 L/Min Vickers Is Rated 180/100 L/Min Must Use Vickers Electronics
4WRZ16E15050/6A12N9Z4D3MRexrothValveKDG5V72C180NEXVMUG110VickersMust Use Vickers Electroincs, With The 12Vdc Coils Only Option Is The Ehhamp712D20 Power Plug
4WRZ16W115060/6A24N9EK4/D3MRexrothValveKDG5V733C130N65XVMUH110VickersRr Spool Is Rated 150/75 L/Min Vickers Is 130/65 L/Min Must Use Vickers Electronics
4WRZ32W252050/6A24N9EZ4RexrothValveKDG5V1033C550N310HMUH110VickersRr Spool Is Rated 520/260 L/Min Vickers Is 550/310 L/Min Must Use Vickers Electronics
4WS2EM1045/5B2ET315Z8BMRexrothValveSM420(2.5)9300/3050S135VickersRr Is Rated 5 L/Min, Vickers Has 3,8 Or 9 L/Min S135 Means Matches Rexroth Wiring And Underlap Option
4WS2EM1045/5B2T315Z8DBRexrothValveSM420(2.5)9300/3050S46 + SM4A52050VickersS46 = REXROTH WIRING, WILL NEED TO ACTIVATE 5TH PORT FOR EXTERNAL PILOT SUPPLY, CONTACT TECHNICAL SUPPORT FOR INSTRUCTIONS
4WS2EM1045/5B2T315Z8DBRexrothValveSM420(2.5)9300/3050S46+SM4A52050VickersS46 = Rexroth Wiring, Will Need To Activate 5Th Port For External Pilot Supply, Contact Technical Support For Instructions
4WS2EM611/20F12ET315Z17EMRexrothValveSM410(5)1980/5010S46 + SM4A31010VickersRR IS RATED 315 BAR, VICKERS SM410 IS 3000 PSI S46 MEANS MATCHES REXROTH WIRING
4WS2EM611/20F12ET315Z17EMRexrothValveSM410(5)1980/5010S46+SM4A31010VickersRr Is Rated 315 Bar, Vickers Sm410 Is 3000 Psi S46 Means Matches Rexroth Wiring
A10VSO10DR/52RPKC64N00RexrothPumpPVM018ER02AE01ASA28000000A0AVickersRR IS A 10CC/REV PUMP, CLOSEST VICKERS IS AN 18CC/REV, WITH MAX VOLUME ADJ OPTION CAN SET VICKERS DOWN TO 10CC
A10VSO140 DFR/31RPPB12K02RexrothPumpPVM141ER19KS02AAB2311000CA0A, CLOSEST VICKERSVickersshaft 40mm diameter versus 45mm for RR, pilot diameter 160mm versus 180mm, flange ports are SAE diameter but with metric threads, Vickers SAE diameter flanges with inch threads.
A10VSO140 DFR/31RPPB12K02RexrothPumpPVM141ER19KS02AAB2311000CA0A,CLOSESTVICKERSVickersShaft 40Mm Diameter Versus 45Mm For Rr, Pilot Diameter 160Mm Versus 180Mm, Flange Ports Are Sae Diameter But With Metric Threads, Vickers Sae Diameter Flanges With Inch Threads.
AA10VSO18DRG/31RPKC62N00RexrothPumpPVM018ER02AS02AAC28110000A0AVickersNEED TO OBTAIN SPECIAL PLUMBING INSTRUCTIONS, ONLY WAY TO ACHIEVE THE CONTROL EQUAL TO THE RR DRG
AA10VSO45DFR31RVKC62K05RexrothPumpPVM045ER06CS02AAB2811000DA0AVickersREXROTH HAS SAE BB STRAIGHT KEY THRU DRIVE VICKERS ONLY OFFERS SPLINE THRU-DRIVE SHAFTS CROSS IS WITH AN SAE BB SPLINED OUTPUT SHAFT
AA10VSO71DR31RPKC62K40RexrothPumpPVM074ER09ES02ASA2800000BA0AVickersRR HAS SAE C STRAIGHT DIA OUTPUT SHAFT (K40) VICKERS ONLY OFFERS SPLINE OUTPUT SHAFTS CROSSED TO SAME MOUNT BUT WITH 11 TOOTH SPLINE SHAFT
AA2FM90/61WVQD520RexrothMotorBAF Series is no longer Available. Contact Tech Support.EatonRR SPLINED SHAFT IS 14T, 16/32 DP VICKERS SHAFT IS 13T 8/16 DP
AA4VG180HD1DM132LNSDS2F021DRRexrothPumpHPV210L0S4MH1200L21SAFBFAE0000000AAAEATONOUR INPUT SHAFT IS NOT THE SAME, WE HAVE A 15 TOOTH 8/16 DP, RR HAS 13 TOOTH 8/16 DP
AA4VSO250DR/31RPB1N00RexrothPumpPVXS250M06R0001R01SV0ADF000A0000000000000000010HydroKraftRR PILOT DIA IS 224MM AND SHAFT DIA IS 60MM VICKERS PILOT DIA IS 200MM AND SHAFT DIA 65MM
FESE40CA3X670LK0B1MRexrothValveCVU40EFP1B297031EN107 OR CVU40EFP1B299031VickersEN107 = 40MM CARTRIDGE WITH 700 L/MIN FLOW RATED SPOOL TO MATCH REXROTH IS 670 L/MIN SPOOL, STANDARD CVU-40 IS 900 L/MIN
FESE40CA3X670LK0B1MRexrothValveCVU40EFP1B297031EN107ORCVU40EFP1B299031VickersEn107 = 40Mm Cartridge With 700 L/Min Flow Rated Spool To Match Rexroth Is 670 L/Min Spool, Standard Cvu-40 Is 900 L/Min
H4WEH16U10B6X/11060Z5LQ0G24RexrothValveDG5V731CPCAEZVMU6B630VickersVickers Pca Is The Recommended Option To Replace The Rr Q0G24. Rr Used Two Switches, We Use One To Obtain The Same Result.
HED8OH12/100K14RexrothValveSG307F150 + DGMP3*B10Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.
HED8OH12/100K14RexrothValveSG307F150+DGMP3*B10Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.
HED8OH12/100Z14 SRexrothValveSG307F150 + DGMP3*B10,Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.
HED8OH12/100Z14 SRexrothValveSG307F150+DGMP3*B10,Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.
HED8OH12/200K14RexrothValveSG307F350 + DGMP3*B10Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.
HED8OH12/200K14RexrothValveSG307F350+DGMP3*B10Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.
HED8OH12/50K14RexrothValveSG307F55 + DGMP3*B10Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.
HED8OH12/50K14RexrothValveSG307F55+DGMP3*B10Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.
LC25DB40D7X/RexrothValveCVI25D10H40EN9VickersRr Cracking Pressure Is 4,0 Bar, Vickers Is 3,1 Bar Vickers Rate Gives The Vickers The Best Performancewhen Used With The Relief Covernote
LC32DB20E7X/RexrothValveCVI32D10H40EN9VickersRr Cracking Pressure Is 2,0 Bar, Vickers Is 3,1 Barthis Is For The Best Performance When Used Withvickers Pressure Control Coversnote
LC40DB20B7X/RexrothValveCVI40C10FC40EN9VickersRr Cracking Pressure Is 2,0 Bar, Vickers Is 2,35 Barfor The Best Performance With Vickers Pressurerelief Coversnote
LC40DR40E7X/RexrothValveCVI40X240EN9VickersOnly Vickers Insert For Pressure Reducing Functionnot Enough Informaton On The Rr To Completelyvalidate Crossnote
LFA16EWA6X/CA20DQMG24/12RexrothValveCVU16ZSWD3B29M10VickersRr Cracking Pressure Is 2 Bar, Vickers Is 2.5 Bar, Also Rr Has Inch Based Threads. Vickers Only Offer Metric With This Style
LFA25WEB62/12RexrothValveCVCS25D3B2910VickersRexroth Uses Single Solenoid Offset Directionals Where They Direct Oil Specifically To The A Or B Port, The Vickers Uses Double Solenoid And Can Direct To Either A Or B By Which Solenoid It Energizes,
PV717/2530RE01MC016RexrothPumpPVM045ER17DS05AAA1600000AA0AVickersRR HAS 100MM 4 BOLT MOUNT, VICKERS IS 100MM 2 BOLT, OUR THRU DRIVE IS NOT THE SAME, WE HAVE SAE A2 BOLT PAD WITH 9 TOOTH SPLINE SHAFT, RR IS SPECIAL SPLINE AND PAD FOR MOUNTING ANOTHER PV7 PUMP
Z2FS1021X/2QVRexrothValveDGMFN5XA2WB2W30 OR DGMFN5YA2WB2W30VICKERSDGMDN5X - METER-IN, DGMFN5Y - METER-OUT, RR CAN BE EITHER BASED ON ASSEMBLED POSITION
Z2S1013X/V (Z2SRK10)RexrothValveDGMPC5DABKDBAK30VickersRr Is 22 Psi Cracking Psi, Vickers Is 15 Psi, The Z2Srk Is Fixed Cracking Pressure & Rated For 21 Gpm, The Z2S Is 32 Gpm And Has Options For Different Cracking Pressures
Bosch Rexroth hydraulic pumps have a long history of quality and dependability. Bosch Rexroth is one of the largest suppliers of hydraulic components for industrial applications worldwide.
Bosch Rexroth hydraulic pumps are designed to meet the needs of a wide range of industrial and commercial applications. Their products are engineered to provide years of trouble free operation even in the most demanding environments.
We offer a large selection of hydraulic pumps from Bosch Rexroth, including high pressure hydraulic pumps, low pressure hydraulic pumps and variable displacement pumps cross reference Parts.
Cat Hydraulic Pump Cross Reference. All of these pumps are cross referenced with Caterpillar PNs. This is from a 2012 Cat Dealer Tech book. It should be noted that the cross reference data varies between different versions of the same pump. These listings are not Caterpillar OEM parts, but they have been used in Cat machines.
1217385GEAR PUMP-HYDRAULIC414E, 416C, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424B, 424B HD, 424D, 426C, 428C, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 436C, 438C, 438D, 442D, 442E, 444E, 444F
1262016GEAR PUMP-HYDRAULIC318C, 319C, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 321C, 321D LCR, 322C, 322C FM, 323D L, 323D LN, 323D SA, 324D, 324D FM, 324D FM LL, 324D L, 3...
2P9313GEAR PUMP-HYDRAULIC621, 621B, 621E, 621F, 621G, 621H, 621K, 621R, 623B, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 631D, 631E, 631G, 633D, 633E II, 637D, 637E, 637G, 639D
2078235GEAR PUMP-HYDRAULIC320C, 330C, 330C FM, 330C L, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336E, 336E HVG, 336E L, 336E LN, 345D, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, M330D
3P0203GEAR PUMP-HYDRAULIC621, 621B, 621E, 621F, 621G, 621H, 621K, 621R, 623B, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC
3P0204GEAR PUMP-HYDRAULIC621, 621B, 621E, 621F, 621G, 621H, 621K, 621R, 623B, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC
6Y8764GEAR PUMP-HYDRAULIC120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
6Y8765GEAR PUMP-HYDRAULIC120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
Eaton is a well-established brand of pumps and has been manufacturing them since 1907. In recent years, Eaton has generated business by providing hydraulic pumps to various businesses across the world. To connect with these businesses they offer a catalogue of hydraulic pumps and other equipment. Unfortunately, this catalogue isn’t a very effective way to search for the specific pump you need. This leaves businesses stuck in an awkward situation where they have to browse their company’s catalogues to search for the correct part or risk ordering the incorrect part from Topkitparts website. To combat this frustrating situation, we offers a cross reference guide for their hydraulic pumps on us website.
Muncie hydraulic pump cross reference in a friendly tone:muncie hydraulic pump cross reference by Larsen Muncie Hydraulics Inc. is one of many reputable brands of hydraulic pumps and other related elements, you will be able to find these in almost all types of industries, they are very important as they are needed in your operations if you’re using hydraulics, if you don’t use the correct size of pump or reservoir with your system, it can cause damage to other parts and machine itself.
Hopefully this article has provided everything you need to know about commercial hydraulic pump cross reference. You also want to know more information or details, you can visit our website or contact us by leaving a comment below.
Vickers V10, V20, V2010 & V2020 series fixed displacement vane pumps are a balanced rotor design with the benefits of a long service life and low noise levels at a low cost. We stock remanufactured Vickers units, aftermarket interchange units, replacement parts (cartridge kits) and provide repairs.
Vickers V & VQ series fixed displacement vane pumps feature a intra-vane design that provides excellent serviceability, efficiency and service life. We stock remanufactured Vickers units, aftermarket interchange units, replacement parts (cartridge kits) and provide repairs.
The Vickers M series of motors are capable of operating at high speeds and high pressures. These units can also be run in either direction of rotation. We stock remanufactured Vickers M series units, replacement parts (cartridge kits and such) and provide repairs.
We specialize in Vickers MHT remanufacturing and repairs. In fact, some of our equipment used to repair and test these units was purchased directly from Vickers. Many units are in stock and available for immediate delivery. We stock remanufactured Vickers units, replacement parts and provide repairs.
The Vickers PVB, PVH, PVE & PVQ lines are piston pump products that are engineered, designed around and commonly used on a variety of industrial and mobile applications. We stock remanufactured Vickers units, aftermarket interchange units, replacement parts and provide repairs.
Vickers TA series units are a hydrostatic transmission based piston product designed for medium duty mobile applications - agriculture equipment, construction and material handling equipment. We stock remanufactured Vickers units, replacement parts and provide repairs.
We carry an extensive inventory of remanufactured and aftermarket Vickers hydraulic piston & vane pumps and motors including MVE, MFB, TB and M2-210 series units. Many units are in stock and available for immediate delivery.
At Panagon Systems, we manufacture hydraulic piston pumps to OEM specifications, and guarantee OEM quality. We can provide hydraulic pump replacements for the following brands:
A hydraulic pump needs to be carefully matched to the hydraulic system for optimal performance. Whether you need the latest replacement pump or an obsolete component, search our diverse range of
If you can’t find the pump you need, discuss your requirements with our team. We’ll work with you to supply the solution that fits your industry and your application.
We make rebuilds/replacements as easy for you as possible. If you aren’t sure what type of service you need, we’ll inspect your hydraulic pump and help you determine the best course of action.
Our full replacement process includes:First, you fill out our. Please include all of the information you have about the problem you’re experiencing. We also recommend attaching a photo of the pump, though this is not required.
Once we receive your pump, we will inspect it and diagnose the problem. When our technicians have identified the problem, they will come up with a plan of action.
When we have finished disassembling and cleaning the pump, we will determine the usable and unusable components, which will then help us finalize the rebuild plan.
After inspection and disassembly, we will send you a report of our findings (condition of pump, total cost estimate, and project outline). We will not start any work until you approve our rebuild plan.
Hydraulic pumps can last for a long time before needing to be replaced. In fact, some pumps can operate for up to 20,000 hours with proper maintenance. However, hydraulic pumps do fail eventually. In general, the lifespan of a pump depends on the level of maintenance it receives, the quality of oil that is used, and its operating conditions.
The costs for hydraulic pump rebuilding or repair vary widely. There are many factors that affect the cost, including the brand of pump, how many components need to be replaced, and more. At Panagon Systems, we always provide our customers with a detailed estimate and wait for permission before starting any work.
Are you looking for OEM-quality hydraulic pump replacements? Turn to Panagon Systems. We’re the largest manufacturer of hydraulic piston pumps in the United States, and guarantee quality in all replacement pumps. In addition to delivering OEM-quality, we’re also associated with the,, and.
Permco pumps are typically used in demanding applications such as dump trailer, live floor and goose neck. These applications are known for their unforgiving and harsh environments. With over 50 years experience, Permco manufactured pumps are designed perform reliably under these types of demanding conditions while still maintaining a long service-life.
Prior to 1997 the company went through several acquisitions and brands; Concentric, John S. Barnes, Vickers, Hof, Statesville. In 1997 the brand changed their name to Haldex Barnes Hydraulics.
We can help! Call (800) 765-5670 to speak with one of our helpful representatives or email service@hydraulic.net for a quote. Call or email for your replacement John S. Barnes, JBS, Haldex Barnes Hydraulic Gear Pump.
G20s and G30s were designed by a company called Double A Hydraulics in the 70’s which later became Vickers and eventually sold to John S. Barnes which ultimately became Haldex. The Haldex brand was never the cheapest on the market but known for their durability and high quality.
GC pumps originally called John S. Barnes were one of the first hydraulic pumps to get a patent in 1935. Over the last 80 years more than 300K versions of this pump have been produced. A vast majority of these versions are obsolete. GC Series Hydraulic Pumps are compact, external gear models for use in pumping fluids with lubricating qualities. They are suitable for use in a wide variety of agricultural, construction equipment, robotics, and material handling in addition to machine tools and other types of machinery.
Hydraulic.net produces many of these obsolete pumps today. We are your resources for GC, G20, and G30 replacement pumps built to original specifications. Our track record over the last 30 years of working with major OEMs designing and producing hydraulic pumps allows us to keep providing the market with these obsolete and hard to find pumps.
Haldex W900 and W1500 Hydraulic Gear Pump Series are two families in the W series offering high performance, flexibility, low and high-speed operation and efficiency, and are ideal for low noise applications. The range of applications utilizing the W900 and w1500 series varies from agricultural, paving, aerial lifts, material handling, construction, paving, winch and turf care.
Looking for a Haldex Hydraulic Gear Pump? Call (800) 765-5670 to speak with one of our helpful representatives or email service@hydraulic.net for a quote.
Metaris offers a full line of piston pump replacement parts that meet or exceed the specifications of competitive products. We regularly stock parts like: Ball Guides, Bearings, Block Springs & Disc Springs, Cylinder Blocks & Valve Plates, Housings & Casings, Pilot Pumps, Piston Sets, Seal Kits, Set Plates, Shoe Plates, Shafts, Swash Plate Assemblies, Bolts & Screws and much, much more.