vickers <a href='https://www.ruidapetroleum.com/product/47'>hydraulic</a> <a href='https://www.ruidapetroleum.com/product/49'>pump</a> cross reference made in china

Innovation, quality and reliability are the core values of our company. These principles today more than ever form the basis of our success as an internationally active mid-size company for Vickers Hydraulic Pump Cross Reference, Concrete Pump Truck Operator Jobs, Hydraulic Gear Pump Parts, Vickers Vane Pump Cartridge Kits,Hydraulic Pump Unloading. We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits. The product will supply to all over the world, such as Europe, America, Australia,Gabon, Ireland,Ethiopia, Johor.We focus on providing service for our clients as a key element in strengthening our long-term relationships. Our continual availability of high grade products in combination with our excellent pre-sale and after-sales service ensures strong competitiveness in an increasingly globalized market.

vickers <a href='https://www.ruidapetroleum.com/product/47'>hydraulic</a> <a href='https://www.ruidapetroleum.com/product/49'>pump</a> cross reference made in china

The market today is flooded with various types of hydraulic pump cross reference guides. With different makes and models, it is critical to find the right cross reference guide that will work with your hydraulic pump style, size and type. At HPCROSSREF.com, we offer a comprehensive catalog of cross reference guides that will fit a variety of different hydraulic pump styles, sizes and types. Our catalog includes over 50 cross references for high performance pumps for lifts, cranes and other hydraulics power applications.

The following is a list of some of the most common Cessna hydraulic pumps. If you have an older model, chances are it won’t be listed here. However, if you have an older model, it’s likely that your hydraulic pump will be similar in size to one of the newer models listed below.

Hydraulic pumps from Parker are used on many different applications, including construction equipment, heavy machinery, and agricultural equipment. If you need to replace your Parker pump, we have a wide selection of hydraulic pumps for you to choose from. Our hydraulic pumps are produced to meet or exceed OEM specifications and performance. We offer parker hydraulic pump cross reference charts to help you get the right part for your machine so you can get back to work as soon as possible!

1PV2V418/20RW12VW100ARexrothPumpPVM020ER17DS01AAH00200000A0AVickersRR HAS A 4 BOLT MOUNT, VICKERS IS 2 BOLT, VICKERS CONTROL OPTION WILL REQUIRE ADDED VALVESTO ACHIEVE THE DUAL STAGE ELECTRONICALLY CONTROLLED

4WE10D2X/OFA120/60NDZALVRexrothValveDG4V52NVMU6EK620VickersRr Dzal Is A Special Connector That Screws Into The Conduit Cavity Of The Valve Body, Vickers Does Not Offer That Type Of Connection, Suggest Using The Din Type Coils And Connector

4WE10E33/CW110RNG24K4RexrothValveDG4V52CHJVMU12DJ620VickersRr R Is For Rectified 110Vac To Dc, Vickers U12 Is For Din Connector With Rectifier Dj Is For 98Vdc Which Is The Accepted Rectified Dc Voltage For 110Vac

4WE10EB3X/CG24NK4QBG24RexrothValveDG4V52BLJHVMS6UH620VickersRr Uses A Contact Type Spool Position Monitoring Switch Vickers Offers An Lvdt Type In The Dg4V-5 Series

4WE10G11/LW110RNZ55VRexrothValveDG4V58CJVMU12DJ620VickersRr R Is For Rectified 110Vac To Dc, Vickers U12 Is For Din Connector With Rectifier Dj Is For 98Vdc Which Is The Recommended Dc Voltage To Accept Rectified 110Vac

4WE10G32/CW110RN9Z55L/ARexrothValveDG4V58CJVMU11DJ620VickersRr R Is For Rectified 110Vac To Dc, Vickers U11 Is For Din Connector With Rectifier And Lights Dj Is For 98Vdc Which Is The Recommended Dc Voltage To Accept Rectified 110Vac

4WE10GB3X/CW110N9K4RexrothValveDG4V58BVMUEK620VickersVickers Equal Does Not Offer Dual Frequency 110/120Vac Like Rr, Ek Is 120Vac60Hz Single Frequency

4WE10JB3X/CG96N9K4QBG24RexrothValveDG4V56BJVMS6UDJ620VickersRr Qbg24 Is Contact Style Spool Monitoring Switch Vickers Dg4V-5 Series Only Offers Lvdt Type

4WE10R31/LW12060NDALVRexrothValveF3DG4V40152CVMWLB510VickersNormally Rr L Is For Air Gap, Vickers Air Gap Does Not Have Pressure Rating Of The Rexroth

4WE6D52/AW12060NK4QBG24RexrothValveDG4V32AHVMS6U1B660VickersRexroth Qbg24 Is A N.O./N.C. Contact Type Spool Position Switch Only Vickers Spool Position Switch With The Din Coils Is The S6 Version, Lvdt Type.

4WEH16L6X/6EW110N9ES2Z5L/10RexrothValveDG5V73C2VMU6B630VickersVickers Spool Transition Is Slightly Different When B Is Energized Transition Is Ports Blocked, Rr Is Ports Blocked With Restricted Bleed Off For B To T

4WEH22H7X/6AW110N9ETSDAP4.5RexrothValveDG5V8H0C2TSVMFWB10VickersRr S Is For Meter-In Pilot Chokes, We Only Offer Meter-Out Pilot Chokes, Code Option 2. Rr P4.5 Is For 65 Psi P Port Check, We Have 75 Psi, Code Option S.

4WRAB6W2511/G24N9DK25VRRexrothValveKDG4V333C20NHMU1H760VickersRr Spool Is Rated 25 L/Min, Vickers Is Rated 20 L/Min, Also We Do Not Offer The 5 Pin Connector In The Hp Kdg4V3 Must Use Vickers Electronics

4WRAE10WA602X/G24N9K31A1RexrothValveKBTG4V533B70NZM1PE7H710EN56VICKERSRR SPOOL RATED 60 L/MIN AT 10 BAR DROP, VICKERS IS 70 L/MIN, RR HAS MANUAL OVERRIDES, VICKERS DOES NOT

4WRD10V10040/10L2Z9/VRexrothValveKHDG5V55C85NEXVMU1H120VickersRr Has Servo Valve As Pilot, Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 100 L/Min Vickers Is Rated 85 L/Min

4WRD10V5040/10L2Z9/VRexrothValveKHDG5V55C85NEXVMU1H120VickersRr Has Servo Valve As Pilot, Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 50 L/Min Vickers Is Rated 85 L/Min

4WRD16V1003X/10L2TZ8MRexrothValveKHDG5V75C200NEXVMU1H120VickersRr Has Servo Valve As Pilot, Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 100 L/Min Vickers Is Rated 200 L/Min

4WRDE10V100L51/6L24Z9/M202RexrothValveKBHDG5V55C85NEXM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 100 L/Min Vickers Is Rated 85 L/Min

4WRDE10V50P5X/6L24ETK9/MR280RexrothValveKBHDG5V55C85NTM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 50 L/Min Vickers Is Rated 85 L/Min

4WRDE16E125L51/6L24TZ9RexrothValveKBHDG5V72C200NEXTM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 125 L/Min Vickers Is Rated 200 L/Min

4WRDE16V1125L5X/6L24ETK9VRexrothValveKBHDG5V75C200N115TM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 125/63 L/Min Vickers Is Rated 200/115 L/Min

4WRDE16V125L51/6L24Z9/M202RexrothValveKBHDG5V75C200NEXM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 125 L/Min Vickers Is Rated 200 L/Min

4WRDE16W152.8P5X/6L24Z9VRRexrothValveKBHDG5V733C160NEXM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 200 L/Min Vickers Is Rated 160 L/Min

4WRE10E2641X/24Z4VRexrothValveKFDG4V52C50N25ZVMU1H720VickersE2 Rr Has Different Flow Division, Rr Q/Max Is For P To B, Vickers Is P To A Also Rr Spool Rated To 64/32 L/Min Vickers Is Rated 50/25 L/Min Must Use Vickers Electronics

4WRE6E081X/24K4MRexrothValveKFDG4V32C13NZVMUH720VickersMust Use Vickers Electronics For Guaranteed Performance Rr Spool Is Rated 8 L/Min, Closest Vickers Is 13 L/Min

4WRE6E081X/24Z4MRexrothValveKFDG4V32C13NZVMU1H720VickersMust Use Vickers Electronics For Guaranteed Performance Rr Spool Is Rated 8 L/Min, Closest Vickers Is 13 L/Min

4WRE6EA3212/24Z4/MRexrothValveKFTG4V32B20NZVMU1H720VickersRr Spool Is Rated 32 L/Min, Vickers Is Rated 20 L/Min Must Use Vickers Electronics For Guaranteed Performance

4WREE10W1752X/G24/K31/A1VRexrothValveKBFDG4V533C50N25ZM1PE7H711VickersRr Spool Is Rated Is 75/38 L/Min, Vickers Is Rated 50/25 L/Min, Will Handle 75/38 But With Increased Pressure Drop

4WREE10W1752X/G24/K31/F1VRexrothValveKBFDG4V533C50N25ZM2PE7H711VickersRr Spool Is Rated Is 75/38 L/Min, Vickers Is Rated 50/25 L/Min, Will Handle 75/38 But With Increased Pressure Drop

4WREE6EA3222G24K31A1VRexrothValveKBFTG4V32B20NZM1PE7H711VickersRr Spool Is Rated To 32 L/Min, Vickers Is 20 L/Min But Can Go To 32 L/Min With Increased Delta P

4WRLE16EZ180SJ3XG24K0A1M OLD BOSCH 0811404305RexrothValveKBHDG5V72C200NEXM1PE7H411VickersBosch Valve Has Pressure Tapping Ports For Better Delta P Signal For Load Sensing, Review Application

4WRLE16WZ180SJ3X/G24K0/A1M/OLD BOSCH 0811404307RexrothValveKBHDG5V733C160NEXM1PE7H411VickersClosest Vickers, The Rr Has Pressure Tapping Ports To Each End Of The Spool For Detecting Delta P For Hydrostatic Function, Vickers Does Not Offer This. Also The Rr Spool Is Rated To 180 L/Min Vickers Is 160 L/Min

4WRLE25WZ350SJ3X/G24K0/A1M/OLD BOSCH 0811404456RexrothValveKBHDG5V833C375NEXM1PE7H411VickersClosest Vickers, The Rr Has Pressure Tapping Ports To Each End Of The Spool For Detecting Delta P For Hydrostatic Function, Vickers Does Not Offer This. Also The Rr Spool Is Rated To 350 L/Min Vickers Is 375 L/Min

4WRTE25Q23502X/6BG24Z9/M/RRexrothValveKBHDG5V833C375NEXM1PH7H411VickersRr Spool Is Rated 350 L/Min Vickers Is 375 L/Min Rr Spool Transitions Are Different, But Center And Shifted Functions Are The Same

4WRTE25Q2350P31/6G24Z31RexrothValveKBHDG5V833C375NEXM1PH7H411VickersRr Spool Is Rated 350 L/Min Vickers Is 375 L/Min Rr P Is Linear Flow With Fine Control Basically The Initial 25 % Of Spool Shift Has A More Deliberate Flow Rise Rr Spool Transitions Are Different, But Center And Shifted Functions Are The Same

4WRTE25Q2350P4X/6EG24K31A5MRexrothValveKBHDG5V833C375NEXM1PH7H411VickersRr Spool Is Rated 350L/Min, Vickers Is 375L/Min Rr P Is Linear Flow With Fine Control Basically The Initial 25% Of Spool Shift Has A More Deliberate Flow Rise Rr Spool Transitions Are Different, But Center And Shifted Functions Are The Same

4WRZ10W1854X/6A24N9EZ4D3MRexrothValveKDG5V533C60N40XVMUH110VickersRr Spool Is Rated 85/42 L/Min Vickers Is Rated 60/40 L/Min Must Use Vickers Electroincs

4WRZ16E110031/6A24NZ4D2RexrothValveKDG5V72C180N100EXVMUH110VickersRr Spool Is Rated 100/50 L/Min Vickers Is Rated 180/100 L/Min Must Use Vickers Electronics

4WRZ16E15050/6A12N9Z4D3MRexrothValveKDG5V72C180NEXVMUG110VickersMust Use Vickers Electroincs, With The 12Vdc Coils Only Option Is The Ehhamp712D20 Power Plug

4WRZ16W115060/6A24N9EK4/D3MRexrothValveKDG5V733C130N65XVMUH110VickersRr Spool Is Rated 150/75 L/Min Vickers Is 130/65 L/Min Must Use Vickers Electronics

4WRZ32W252050/6A24N9EZ4RexrothValveKDG5V1033C550N310HMUH110VickersRr Spool Is Rated 520/260 L/Min Vickers Is 550/310 L/Min Must Use Vickers Electronics

4WS2EM1045/5B2ET315Z8BMRexrothValveSM420(2.5)9300/3050S135VickersRr Is Rated 5 L/Min, Vickers Has 3,8 Or 9 L/Min S135 Means Matches Rexroth Wiring And Underlap Option

4WS2EM1045/5B2T315Z8DBRexrothValveSM420(2.5)9300/3050S46 + SM4A52050VickersS46 = REXROTH WIRING, WILL NEED TO ACTIVATE 5TH PORT FOR EXTERNAL PILOT SUPPLY, CONTACT TECHNICAL SUPPORT FOR INSTRUCTIONS

4WS2EM1045/5B2T315Z8DBRexrothValveSM420(2.5)9300/3050S46+SM4A52050VickersS46 = Rexroth Wiring, Will Need To Activate 5Th Port For External Pilot Supply, Contact Technical Support For Instructions

4WS2EM611/20F12ET315Z17EMRexrothValveSM410(5)1980/5010S46 + SM4A31010VickersRR IS RATED 315 BAR, VICKERS SM410 IS 3000 PSI S46 MEANS MATCHES REXROTH WIRING

4WS2EM611/20F12ET315Z17EMRexrothValveSM410(5)1980/5010S46+SM4A31010VickersRr Is Rated 315 Bar, Vickers Sm410 Is 3000 Psi S46 Means Matches Rexroth Wiring

A10VSO10DR/52RPKC64N00RexrothPumpPVM018ER02AE01ASA28000000A0AVickersRR IS A 10CC/REV PUMP, CLOSEST VICKERS IS AN 18CC/REV, WITH MAX VOLUME ADJ OPTION CAN SET VICKERS DOWN TO 10CC

A10VSO140 DFR/31RPPB12K02RexrothPumpPVM141ER19KS02AAB2311000CA0A, CLOSEST VICKERSVickersshaft 40mm diameter versus 45mm for RR, pilot diameter 160mm versus 180mm, flange ports are SAE diameter but with metric threads, Vickers SAE diameter flanges with inch threads.

A10VSO140 DFR/31RPPB12K02RexrothPumpPVM141ER19KS02AAB2311000CA0A,CLOSESTVICKERSVickersShaft 40Mm Diameter Versus 45Mm For Rr, Pilot Diameter 160Mm Versus 180Mm, Flange Ports Are Sae Diameter But With Metric Threads, Vickers Sae Diameter Flanges With Inch Threads.

AA10VSO18DRG/31RPKC62N00RexrothPumpPVM018ER02AS02AAC28110000A0AVickersNEED TO OBTAIN SPECIAL PLUMBING INSTRUCTIONS, ONLY WAY TO ACHIEVE THE CONTROL EQUAL TO THE RR DRG

AA10VSO45DFR31RVKC62K05RexrothPumpPVM045ER06CS02AAB2811000DA0AVickersREXROTH HAS SAE BB STRAIGHT KEY THRU DRIVE VICKERS ONLY OFFERS SPLINE THRU-DRIVE SHAFTS CROSS IS WITH AN SAE BB SPLINED OUTPUT SHAFT

AA10VSO71DR31RPKC62K40RexrothPumpPVM074ER09ES02ASA2800000BA0AVickersRR HAS SAE C STRAIGHT DIA OUTPUT SHAFT (K40) VICKERS ONLY OFFERS SPLINE OUTPUT SHAFTS CROSSED TO SAME MOUNT BUT WITH 11 TOOTH SPLINE SHAFT

AA2FM90/61WVQD520RexrothMotorBAF Series is no longer Available. Contact Tech Support.EatonRR SPLINED SHAFT IS 14T, 16/32 DP VICKERS SHAFT IS 13T 8/16 DP

AA4VG180HD1DM132LNSDS2F021DRRexrothPumpHPV210L0S4MH1200L21SAFBFAE0000000AAAEATONOUR INPUT SHAFT IS NOT THE SAME, WE HAVE A 15 TOOTH 8/16 DP, RR HAS 13 TOOTH 8/16 DP

AA4VSO250DR/31RPB1N00RexrothPumpPVXS250M06R0001R01SV0ADF000A0000000000000000010HydroKraftRR PILOT DIA IS 224MM AND SHAFT DIA IS 60MM VICKERS PILOT DIA IS 200MM AND SHAFT DIA 65MM

FESE40CA3X670LK0B1MRexrothValveCVU40EFP1B297031EN107 OR CVU40EFP1B299031VickersEN107 = 40MM CARTRIDGE WITH 700 L/MIN FLOW RATED SPOOL TO MATCH REXROTH IS 670 L/MIN SPOOL, STANDARD CVU-40 IS 900 L/MIN

FESE40CA3X670LK0B1MRexrothValveCVU40EFP1B297031EN107ORCVU40EFP1B299031VickersEn107 = 40Mm Cartridge With 700 L/Min Flow Rated Spool To Match Rexroth Is 670 L/Min Spool, Standard Cvu-40 Is 900 L/Min

H4WEH16U10B6X/11060Z5LQ0G24RexrothValveDG5V731CPCAEZVMU6B630VickersVickers Pca Is The Recommended Option To Replace The Rr Q0G24. Rr Used Two Switches, We Use One To Obtain The Same Result.

HED8OH12/100K14RexrothValveSG307F150 + DGMP3*B10Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.

HED8OH12/100K14RexrothValveSG307F150+DGMP3*B10Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.

HED8OH12/100Z14 SRexrothValveSG307F150 + DGMP3*B10,Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.

HED8OH12/100Z14 SRexrothValveSG307F150+DGMP3*B10,Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.

HED8OH12/200K14RexrothValveSG307F350 + DGMP3*B10Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.

HED8OH12/200K14RexrothValveSG307F350+DGMP3*B10Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.

HED8OH12/50K14RexrothValveSG307F55 + DGMP3*B10Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.

HED8OH12/50K14RexrothValveSG307F55+DGMP3*B10Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.

LC25DB40D7X/RexrothValveCVI25D10H40EN9VickersRr Cracking Pressure Is 4,0 Bar, Vickers Is 3,1 Bar Vickers Rate Gives The Vickers The Best Performancewhen Used With The Relief Covernote

LC32DB20E7X/RexrothValveCVI32D10H40EN9VickersRr Cracking Pressure Is 2,0 Bar, Vickers Is 3,1 Barthis Is For The Best Performance When Used Withvickers Pressure Control Coversnote

LC40DB20B7X/RexrothValveCVI40C10FC40EN9VickersRr Cracking Pressure Is 2,0 Bar, Vickers Is 2,35 Barfor The Best Performance With Vickers Pressurerelief Coversnote

LC40DR40E7X/RexrothValveCVI40X240EN9VickersOnly Vickers Insert For Pressure Reducing Functionnot Enough Informaton On The Rr To Completelyvalidate Crossnote

LFA16EWA6X/CA20DQMG24/12RexrothValveCVU16ZSWD3B29M10VickersRr Cracking Pressure Is 2 Bar, Vickers Is 2.5 Bar, Also Rr Has Inch Based Threads. Vickers Only Offer Metric With This Style

LFA25WEB62/12RexrothValveCVCS25D3B2910VickersRexroth Uses Single Solenoid Offset Directionals Where They Direct Oil Specifically To The A Or B Port, The Vickers Uses Double Solenoid And Can Direct To Either A Or B By Which Solenoid It Energizes,

PV717/2530RE01MC016RexrothPumpPVM045ER17DS05AAA1600000AA0AVickersRR HAS 100MM 4 BOLT MOUNT, VICKERS IS 100MM 2 BOLT, OUR THRU DRIVE IS NOT THE SAME, WE HAVE SAE A2 BOLT PAD WITH 9 TOOTH SPLINE SHAFT, RR IS SPECIAL SPLINE AND PAD FOR MOUNTING ANOTHER PV7 PUMP

Z2FS1021X/2QVRexrothValveDGMFN5XA2WB2W30 OR DGMFN5YA2WB2W30VICKERSDGMDN5X - METER-IN, DGMFN5Y - METER-OUT, RR CAN BE EITHER BASED ON ASSEMBLED POSITION

Z2S1013X/V (Z2SRK10)RexrothValveDGMPC5DABKDBAK30VickersRr Is 22 Psi Cracking Psi, Vickers Is 15 Psi, The Z2Srk Is Fixed Cracking Pressure & Rated For 21 Gpm, The Z2S Is 32 Gpm And Has Options For Different Cracking Pressures

The John S Barnes hydraulic pump seen on the market are old-fashioned hydraulic pumps before 1997, so many people can’t find effective documents and videos about the John S Barnes hydraulic pump. In 1997, the John Barnes S hydraulic pump was officially renamed. For Haldex Barnes Hydraulics, John S Barnes hydraulic pump identification is Haldex Barnes Hydraulics identification, then we teach you how to quickly identify John S Barnes hydraulic pump (Haldex Barnes Hydraulics),But we still provide OEM customized john s barnes hydraulic pump cross reference parts!

Permco (Fluid Permco) has been a leading manufacturer of hydraulic pumps and parts since 1975. With a large selection of high quality products, Permco can meet all your hydraulic pump needs. Permco offers a wide range of products including: Piston Pumps, Gear Pumps, Plunger Pumps, Rotary Vane Pumps and more… We carry both new and used parts for all applications.

The following cross reference table is for the Webster L-Pump, which is a popular pump used in a variety of applications. We have compiled this list to help you find the exact replacement part you need.

We have a large selection of Vickers Hydraulic Pumps. We can provide you with the correct Vickers Hydraulic Pump for your application, as well as help you to find the right replacement part for your existing unit. Our customer service team is ready to assist you in finding the correct part for your application.

We have a large selection of Vickers Hydraulic Pumps in stock. We can provide you with the correct Vickers Hydraulic Pump for your application, as well as help you to find the right replacement part for your existing unit. Our customer service team is ready to assist you in finding the correct part for your application.

1PV2V418/20RW12VW100ARexrothPumpPVM020ER17DS01AAH00200000A0AVickersRR HAS A 4 BOLT MOUNT, VICKERS IS 2 BOLT, VICKERS CONTROL OPTION WILL REQUIRE ADDED VALVESTO ACHIEVE THE DUAL STAGE ELECTRONICALLY CONTROLLED

4WE10D2X/OFA120/60NDZALVRexrothValveDG4V52NVMU6EK620VickersRr Dzal Is A Special Connector That Screws Into The Conduit Cavity Of The Valve Body, Vickers Does Not Offer That Type Of Connection, Suggest Using The Din Type Coils And Connector

4WE10E33/CW110RNG24K4RexrothValveDG4V52CHJVMU12DJ620VickersRr R Is For Rectified 110Vac To Dc, Vickers U12 Is For Din Connector With Rectifier Dj Is For 98Vdc Which Is The Accepted Rectified Dc Voltage For 110Vac

4WE10EB3X/CG24NK4QBG24RexrothValveDG4V52BLJHVMS6UH620VickersRr Uses A Contact Type Spool Position Monitoring Switch Vickers Offers An Lvdt Type In The Dg4V-5 Series

4WE10G11/LW110RNZ55VRexrothValveDG4V58CJVMU12DJ620VickersRr R Is For Rectified 110Vac To Dc, Vickers U12 Is For Din Connector With Rectifier Dj Is For 98Vdc Which Is The Recommended Dc Voltage To Accept Rectified 110Vac

4WE10G32/CW110RN9Z55L/ARexrothValveDG4V58CJVMU11DJ620VickersRr R Is For Rectified 110Vac To Dc, Vickers U11 Is For Din Connector With Rectifier And Lights Dj Is For 98Vdc Which Is The Recommended Dc Voltage To Accept Rectified 110Vac

4WE10GB3X/CW110N9K4RexrothValveDG4V58BVMUEK620VickersVickers Equal Does Not Offer Dual Frequency 110/120Vac Like Rr, Ek Is 120Vac60Hz Single Frequency

4WE10JB3X/CG96N9K4QBG24RexrothValveDG4V56BJVMS6UDJ620VickersRr Qbg24 Is Contact Style Spool Monitoring Switch Vickers Dg4V-5 Series Only Offers Lvdt Type

4WE10R31/LW12060NDALVRexrothValveF3DG4V40152CVMWLB510VickersNormally Rr L Is For Air Gap, Vickers Air Gap Does Not Have Pressure Rating Of The Rexroth

4WE6D52/AW12060NK4QBG24RexrothValveDG4V32AHVMS6U1B660VickersRexroth Qbg24 Is A N.O./N.C. Contact Type Spool Position Switch Only Vickers Spool Position Switch With The Din Coils Is The S6 Version, Lvdt Type.

4WEH16L6X/6EW110N9ES2Z5L/10RexrothValveDG5V73C2VMU6B630VickersVickers Spool Transition Is Slightly Different When B Is Energized Transition Is Ports Blocked, Rr Is Ports Blocked With Restricted Bleed Off For B To T

4WEH22H7X/6AW110N9ETSDAP4.5RexrothValveDG5V8H0C2TSVMFWB10VickersRr S Is For Meter-In Pilot Chokes, We Only Offer Meter-Out Pilot Chokes, Code Option 2. Rr P4.5 Is For 65 Psi P Port Check, We Have 75 Psi, Code Option S.

4WRAB6W2511/G24N9DK25VRRexrothValveKDG4V333C20NHMU1H760VickersRr Spool Is Rated 25 L/Min, Vickers Is Rated 20 L/Min, Also We Do Not Offer The 5 Pin Connector In The Hp Kdg4V3 Must Use Vickers Electronics

4WRAE10WA602X/G24N9K31A1RexrothValveKBTG4V533B70NZM1PE7H710EN56VICKERSRR SPOOL RATED 60 L/MIN AT 10 BAR DROP, VICKERS IS 70 L/MIN, RR HAS MANUAL OVERRIDES, VICKERS DOES NOT

4WRD10V10040/10L2Z9/VRexrothValveKHDG5V55C85NEXVMU1H120VickersRr Has Servo Valve As Pilot, Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 100 L/Min Vickers Is Rated 85 L/Min

4WRD10V5040/10L2Z9/VRexrothValveKHDG5V55C85NEXVMU1H120VickersRr Has Servo Valve As Pilot, Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 50 L/Min Vickers Is Rated 85 L/Min

4WRD16V1003X/10L2TZ8MRexrothValveKHDG5V75C200NEXVMU1H120VickersRr Has Servo Valve As Pilot, Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 100 L/Min Vickers Is Rated 200 L/Min

4WRDE10V100L51/6L24Z9/M202RexrothValveKBHDG5V55C85NEXM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 100 L/Min Vickers Is Rated 85 L/Min

4WRDE10V50P5X/6L24ETK9/MR280RexrothValveKBHDG5V55C85NTM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 50 L/Min Vickers Is Rated 85 L/Min

4WRDE16E125L51/6L24TZ9RexrothValveKBHDG5V72C200NEXTM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 125 L/Min Vickers Is Rated 200 L/Min

4WRDE16V1125L5X/6L24ETK9VRexrothValveKBHDG5V75C200N115TM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 125/63 L/Min Vickers Is Rated 200/115 L/Min

4WRDE16V125L51/6L24Z9/M202RexrothValveKBHDG5V75C200NEXM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 125 L/Min Vickers Is Rated 200 L/Min

4WRDE16W152.8P5X/6L24Z9VRRexrothValveKBHDG5V733C160NEXM1PH7H411VickersRr Has Servo Valve Pilot Vickers Offers Servo Solenoid Pilot Valves Rr Spool Is Rated 200 L/Min Vickers Is Rated 160 L/Min

4WRE10E2641X/24Z4VRexrothValveKFDG4V52C50N25ZVMU1H720VickersE2 Rr Has Different Flow Division, Rr Q/Max Is For P To B, Vickers Is P To A Also Rr Spool Rated To 64/32 L/Min Vickers Is Rated 50/25 L/Min Must Use Vickers Electronics

4WRE6E081X/24K4MRexrothValveKFDG4V32C13NZVMUH720VickersMust Use Vickers Electronics For Guaranteed Performance Rr Spool Is Rated 8 L/Min, Closest Vickers Is 13 L/Min

4WRE6E081X/24Z4MRexrothValveKFDG4V32C13NZVMU1H720VickersMust Use Vickers Electronics For Guaranteed Performance Rr Spool Is Rated 8 L/Min, Closest Vickers Is 13 L/Min

4WRE6EA3212/24Z4/MRexrothValveKFTG4V32B20NZVMU1H720VickersRr Spool Is Rated 32 L/Min, Vickers Is Rated 20 L/Min Must Use Vickers Electronics For Guaranteed Performance

4WREE10W1752X/G24/K31/A1VRexrothValveKBFDG4V533C50N25ZM1PE7H711VickersRr Spool Is Rated Is 75/38 L/Min, Vickers Is Rated 50/25 L/Min, Will Handle 75/38 But With Increased Pressure Drop

4WREE10W1752X/G24/K31/F1VRexrothValveKBFDG4V533C50N25ZM2PE7H711VickersRr Spool Is Rated Is 75/38 L/Min, Vickers Is Rated 50/25 L/Min, Will Handle 75/38 But With Increased Pressure Drop

4WREE6EA3222G24K31A1VRexrothValveKBFTG4V32B20NZM1PE7H711VickersRr Spool Is Rated To 32 L/Min, Vickers Is 20 L/Min But Can Go To 32 L/Min With Increased Delta P

4WRLE16EZ180SJ3XG24K0A1M OLD BOSCH 0811404305RexrothValveKBHDG5V72C200NEXM1PE7H411VickersBosch Valve Has Pressure Tapping Ports For Better Delta P Signal For Load Sensing, Review Application

4WRLE16WZ180SJ3X/G24K0/A1M/OLD BOSCH 0811404307RexrothValveKBHDG5V733C160NEXM1PE7H411VickersClosest Vickers, The Rr Has Pressure Tapping Ports To Each End Of The Spool For Detecting Delta P For Hydrostatic Function, Vickers Does Not Offer This. Also The Rr Spool Is Rated To 180 L/Min Vickers Is 160 L/Min

4WRLE25WZ350SJ3X/G24K0/A1M/OLD BOSCH 0811404456RexrothValveKBHDG5V833C375NEXM1PE7H411VickersClosest Vickers, The Rr Has Pressure Tapping Ports To Each End Of The Spool For Detecting Delta P For Hydrostatic Function, Vickers Does Not Offer This. Also The Rr Spool Is Rated To 350 L/Min Vickers Is 375 L/Min

4WRTE25Q23502X/6BG24Z9/M/RRexrothValveKBHDG5V833C375NEXM1PH7H411VickersRr Spool Is Rated 350 L/Min Vickers Is 375 L/Min Rr Spool Transitions Are Different, But Center And Shifted Functions Are The Same

4WRTE25Q2350P31/6G24Z31RexrothValveKBHDG5V833C375NEXM1PH7H411VickersRr Spool Is Rated 350 L/Min Vickers Is 375 L/Min Rr P Is Linear Flow With Fine Control Basically The Initial 25 % Of Spool Shift Has A More Deliberate Flow Rise Rr Spool Transitions Are Different, But Center And Shifted Functions Are The Same

4WRTE25Q2350P4X/6EG24K31A5MRexrothValveKBHDG5V833C375NEXM1PH7H411VickersRr Spool Is Rated 350L/Min, Vickers Is 375L/Min Rr P Is Linear Flow With Fine Control Basically The Initial 25% Of Spool Shift Has A More Deliberate Flow Rise Rr Spool Transitions Are Different, But Center And Shifted Functions Are The Same

4WRZ10W1854X/6A24N9EZ4D3MRexrothValveKDG5V533C60N40XVMUH110VickersRr Spool Is Rated 85/42 L/Min Vickers Is Rated 60/40 L/Min Must Use Vickers Electroincs

4WRZ16E110031/6A24NZ4D2RexrothValveKDG5V72C180N100EXVMUH110VickersRr Spool Is Rated 100/50 L/Min Vickers Is Rated 180/100 L/Min Must Use Vickers Electronics

4WRZ16E15050/6A12N9Z4D3MRexrothValveKDG5V72C180NEXVMUG110VickersMust Use Vickers Electroincs, With The 12Vdc Coils Only Option Is The Ehhamp712D20 Power Plug

4WRZ16W115060/6A24N9EK4/D3MRexrothValveKDG5V733C130N65XVMUH110VickersRr Spool Is Rated 150/75 L/Min Vickers Is 130/65 L/Min Must Use Vickers Electronics

4WRZ32W252050/6A24N9EZ4RexrothValveKDG5V1033C550N310HMUH110VickersRr Spool Is Rated 520/260 L/Min Vickers Is 550/310 L/Min Must Use Vickers Electronics

4WS2EM1045/5B2ET315Z8BMRexrothValveSM420(2.5)9300/3050S135VickersRr Is Rated 5 L/Min, Vickers Has 3,8 Or 9 L/Min S135 Means Matches Rexroth Wiring And Underlap Option

4WS2EM1045/5B2T315Z8DBRexrothValveSM420(2.5)9300/3050S46 + SM4A52050VickersS46 = REXROTH WIRING, WILL NEED TO ACTIVATE 5TH PORT FOR EXTERNAL PILOT SUPPLY, CONTACT TECHNICAL SUPPORT FOR INSTRUCTIONS

4WS2EM1045/5B2T315Z8DBRexrothValveSM420(2.5)9300/3050S46+SM4A52050VickersS46 = Rexroth Wiring, Will Need To Activate 5Th Port For External Pilot Supply, Contact Technical Support For Instructions

4WS2EM611/20F12ET315Z17EMRexrothValveSM410(5)1980/5010S46 + SM4A31010VickersRR IS RATED 315 BAR, VICKERS SM410 IS 3000 PSI S46 MEANS MATCHES REXROTH WIRING

4WS2EM611/20F12ET315Z17EMRexrothValveSM410(5)1980/5010S46+SM4A31010VickersRr Is Rated 315 Bar, Vickers Sm410 Is 3000 Psi S46 Means Matches Rexroth Wiring

A10VSO10DR/52RPKC64N00RexrothPumpPVM018ER02AE01ASA28000000A0AVickersRR IS A 10CC/REV PUMP, CLOSEST VICKERS IS AN 18CC/REV, WITH MAX VOLUME ADJ OPTION CAN SET VICKERS DOWN TO 10CC

A10VSO140 DFR/31RPPB12K02RexrothPumpPVM141ER19KS02AAB2311000CA0A, CLOSEST VICKERSVickersshaft 40mm diameter versus 45mm for RR, pilot diameter 160mm versus 180mm, flange ports are SAE diameter but with metric threads, Vickers SAE diameter flanges with inch threads.

A10VSO140 DFR/31RPPB12K02RexrothPumpPVM141ER19KS02AAB2311000CA0A,CLOSESTVICKERSVickersShaft 40Mm Diameter Versus 45Mm For Rr, Pilot Diameter 160Mm Versus 180Mm, Flange Ports Are Sae Diameter But With Metric Threads, Vickers Sae Diameter Flanges With Inch Threads.

AA10VSO18DRG/31RPKC62N00RexrothPumpPVM018ER02AS02AAC28110000A0AVickersNEED TO OBTAIN SPECIAL PLUMBING INSTRUCTIONS, ONLY WAY TO ACHIEVE THE CONTROL EQUAL TO THE RR DRG

AA10VSO45DFR31RVKC62K05RexrothPumpPVM045ER06CS02AAB2811000DA0AVickersREXROTH HAS SAE BB STRAIGHT KEY THRU DRIVE VICKERS ONLY OFFERS SPLINE THRU-DRIVE SHAFTS CROSS IS WITH AN SAE BB SPLINED OUTPUT SHAFT

AA10VSO71DR31RPKC62K40RexrothPumpPVM074ER09ES02ASA2800000BA0AVickersRR HAS SAE C STRAIGHT DIA OUTPUT SHAFT (K40) VICKERS ONLY OFFERS SPLINE OUTPUT SHAFTS CROSSED TO SAME MOUNT BUT WITH 11 TOOTH SPLINE SHAFT

AA2FM90/61WVQD520RexrothMotorBAF Series is no longer Available. Contact Tech Support.EatonRR SPLINED SHAFT IS 14T, 16/32 DP VICKERS SHAFT IS 13T 8/16 DP

AA4VG180HD1DM132LNSDS2F021DRRexrothPumpHPV210L0S4MH1200L21SAFBFAE0000000AAAEATONOUR INPUT SHAFT IS NOT THE SAME, WE HAVE A 15 TOOTH 8/16 DP, RR HAS 13 TOOTH 8/16 DP

AA4VSO250DR/31RPB1N00RexrothPumpPVXS250M06R0001R01SV0ADF000A0000000000000000010HydroKraftRR PILOT DIA IS 224MM AND SHAFT DIA IS 60MM VICKERS PILOT DIA IS 200MM AND SHAFT DIA 65MM

FESE40CA3X670LK0B1MRexrothValveCVU40EFP1B297031EN107 OR CVU40EFP1B299031VickersEN107 = 40MM CARTRIDGE WITH 700 L/MIN FLOW RATED SPOOL TO MATCH REXROTH IS 670 L/MIN SPOOL, STANDARD CVU-40 IS 900 L/MIN

FESE40CA3X670LK0B1MRexrothValveCVU40EFP1B297031EN107ORCVU40EFP1B299031VickersEn107 = 40Mm Cartridge With 700 L/Min Flow Rated Spool To Match Rexroth Is 670 L/Min Spool, Standard Cvu-40 Is 900 L/Min

H4WEH16U10B6X/11060Z5LQ0G24RexrothValveDG5V731CPCAEZVMU6B630VickersVickers Pca Is The Recommended Option To Replace The Rr Q0G24. Rr Used Two Switches, We Use One To Obtain The Same Result.

HED8OH12/100K14RexrothValveSG307F150 + DGMP3*B10Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.

HED8OH12/100K14RexrothValveSG307F150+DGMP3*B10Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.

HED8OH12/100Z14 SRexrothValveSG307F150 + DGMP3*B10,Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.

HED8OH12/100Z14 SRexrothValveSG307F150+DGMP3*B10,Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.

HED8OH12/200K14RexrothValveSG307F350 + DGMP3*B10Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.

HED8OH12/200K14RexrothValveSG307F350+DGMP3*B10Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.

HED8OH12/50K14RexrothValveSG307F55 + DGMP3*B10Vickers, * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTHS IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE.

HED8OH12/50K14RexrothValveSG307F55+DGMP3*B10Vickers, * = Port Connection To Pressure Switch, The Rexroths Is Determined By Position Of Next Stack Plate. Check Application To See Which Port They Are Using, Then Choose Appropriate Code.

LC25DB40D7X/RexrothValveCVI25D10H40EN9VickersRr Cracking Pressure Is 4,0 Bar, Vickers Is 3,1 Bar Vickers Rate Gives The Vickers The Best Performancewhen Used With The Relief Covernote

LC32DB20E7X/RexrothValveCVI32D10H40EN9VickersRr Cracking Pressure Is 2,0 Bar, Vickers Is 3,1 Barthis Is For The Best Performance When Used Withvickers Pressure Control Coversnote

LC40DB20B7X/RexrothValveCVI40C10FC40EN9VickersRr Cracking Pressure Is 2,0 Bar, Vickers Is 2,35 Barfor The Best Performance With Vickers Pressurerelief Coversnote

LC40DR40E7X/RexrothValveCVI40X240EN9VickersOnly Vickers Insert For Pressure Reducing Functionnot Enough Informaton On The Rr To Completelyvalidate Crossnote

LFA16EWA6X/CA20DQMG24/12RexrothValveCVU16ZSWD3B29M10VickersRr Cracking Pressure Is 2 Bar, Vickers Is 2.5 Bar, Also Rr Has Inch Based Threads. Vickers Only Offer Metric With This Style

LFA25WEB62/12RexrothValveCVCS25D3B2910VickersRexroth Uses Single Solenoid Offset Directionals Where They Direct Oil Specifically To The A Or B Port, The Vickers Uses Double Solenoid And Can Direct To Either A Or B By Which Solenoid It Energizes,

PV717/2530RE01MC016RexrothPumpPVM045ER17DS05AAA1600000AA0AVickersRR HAS 100MM 4 BOLT MOUNT, VICKERS IS 100MM 2 BOLT, OUR THRU DRIVE IS NOT THE SAME, WE HAVE SAE A2 BOLT PAD WITH 9 TOOTH SPLINE SHAFT, RR IS SPECIAL SPLINE AND PAD FOR MOUNTING ANOTHER PV7 PUMP

Z2FS1021X/2QVRexrothValveDGMFN5XA2WB2W30 OR DGMFN5YA2WB2W30VICKERSDGMDN5X - METER-IN, DGMFN5Y - METER-OUT, RR CAN BE EITHER BASED ON ASSEMBLED POSITION

Z2S1013X/V (Z2SRK10)RexrothValveDGMPC5DABKDBAK30VickersRr Is 22 Psi Cracking Psi, Vickers Is 15 Psi, The Z2Srk Is Fixed Cracking Pressure & Rated For 21 Gpm, The Z2S Is 32 Gpm And Has Options For Different Cracking Pressures

Bosch Rexroth hydraulic pumps have a long history of quality and dependability. Bosch Rexroth is one of the largest suppliers of hydraulic components for industrial applications worldwide.

Bosch Rexroth hydraulic pumps are designed to meet the needs of a wide range of industrial and commercial applications. Their products are engineered to provide years of trouble free operation even in the most demanding environments.

We offer a large selection of hydraulic pumps from Bosch Rexroth, including high pressure hydraulic pumps, low pressure hydraulic pumps and variable displacement pumps cross reference Parts.

Cat Hydraulic Pump Cross Reference. All of these pumps are cross referenced with Caterpillar PNs. This is from a 2012 Cat Dealer Tech book. It should be noted that the cross reference data varies between different versions of the same pump. These listings are not Caterpillar OEM parts, but they have been used in Cat machines.

1217385GEAR PUMP-HYDRAULIC414E, 416C, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424B, 424B HD, 424D, 426C, 428C, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 436C, 438C, 438D, 442D, 442E, 444E, 444F

1262016GEAR PUMP-HYDRAULIC318C, 319C, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 321C, 321D LCR, 322C, 322C FM, 323D L, 323D LN, 323D SA, 324D, 324D FM, 324D FM LL, 324D L, 3...

2P9313GEAR PUMP-HYDRAULIC621, 621B, 621E, 621F, 621G, 621H, 621K, 621R, 623B, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 631D, 631E, 631G, 633D, 633E II, 637D, 637E, 637G, 639D

2078235GEAR PUMP-HYDRAULIC320C, 330C, 330C FM, 330C L, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336E, 336E HVG, 336E L, 336E LN, 345D, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, M330D

3P0203GEAR PUMP-HYDRAULIC621, 621B, 621E, 621F, 621G, 621H, 621K, 621R, 623B, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC

3P0204GEAR PUMP-HYDRAULIC621, 621B, 621E, 621F, 621G, 621H, 621K, 621R, 623B, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC

6Y8764GEAR PUMP-HYDRAULIC120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA

6Y8765GEAR PUMP-HYDRAULIC120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA

Eaton is a well-established brand of pumps and has been manufacturing them since 1907. In recent years, Eaton has generated business by providing hydraulic pumps to various businesses across the world. To connect with these businesses they offer a catalogue of hydraulic pumps and other equipment. Unfortunately, this catalogue isn’t a very effective way to search for the specific pump you need. This leaves businesses stuck in an awkward situation where they have to browse their company’s catalogues to search for the correct part or risk ordering the incorrect part from Topkitparts website. To combat this frustrating situation, we offers a cross reference guide for their hydraulic pumps on us website.

Muncie hydraulic pump cross reference in a friendly tone:muncie hydraulic pump cross reference by Larsen Muncie Hydraulics Inc. is one of many reputable brands of hydraulic pumps and other related elements, you will be able to find these in almost all types of industries, they are very important as they are needed in your operations if you’re using hydraulics, if you don’t use the correct size of pump or reservoir with your system, it can cause damage to other parts and machine itself.

Hopefully this article has provided everything you need to know about commercial hydraulic pump cross reference. You also want to know more information or details, you can visit our website or contact us by leaving a comment below.

vickers <a href='https://www.ruidapetroleum.com/product/47'>hydraulic</a> <a href='https://www.ruidapetroleum.com/product/49'>pump</a> cross reference made in china

Vickers Hydraulic Pump Identification Guide is a guide for identifying Vickers pumps, including the most common types of Vickers pump and how to recognize them.

The nameplate on a Vickers hydraulic pump is located on the back of the pump. The information on this plate will tell you many useful things, such as:

Vickers Gear Pumps have a model number that begins with GD5. The GD5 series is the most common, so this is easy to identify. You can find the model number on the nameplate–if your pump’s nameplate says “GD5,” then it’s a Vickers Gear Pump!

The following 23-digit coding system has been developed to identify standard configuration options for the External Single Gear Pump. Use this model code to specify a pump with the desired features.

Vickers Piston Pumps are high-pressure reciprocating pumps for the transfer of liquids and slurries. They employ a piston-type action to drive fluid into a discharge line by the action of compressed air or gas. They have been built in many sizes from 2 inches (50mm) through 100 inches (2500mm) diameter with capacities up to several thousand gallons per minute.

The design is such that the pump can be used as a single stage inlet or outlet pump, or as a multistage booster pump or booster discharge pump. The main types of Vickers piston pumps are listed below:

There are many series of Vickers piston pumps, but it is also very easy to distinguish by the nameplate. It can be identified mainly by looking at the first few characters on the nameplate.

Vickers Vane Pumps are centrifugal pumps with reciprocating piston rods and fixed vanes. These pumps can be used for a wide range of pumping applications, including water treatment, chemical processing and industrial manufacturing. Vickers Vane Pumps are available in cast iron or stainless steel materials and can operate at ambient temperatures up to 250°F (121°C).

Vickers Vane Pumps are available in both single-stage and double-stage designs. Single-stage units have a single pump casing that houses the head, impeller and volute. This design offers higher flow capacities when compared to double-stage designs, but requires additional piping for the discharge line. Double-stage units have two pump casings: one housing the suction side, which includes the suction valve plate; the other housing the discharge side, which includes the discharge valve plate. This design offers greater flexibility in operating pressures and flows than single stage models.

We cannot identify the Vickers hydraulic pump model if the Vickers hydraulic pump nameplate is damaged. Here our engineers have prepared for you to identify the specific model of the Vickers hydraulic pump by the appearance of the Vickers hydraulic pump

The exterior of a Vickers pump is usually very easy to identify. There are only two different types of exterior housings available for Vickers pumps: cylindrical and square. The most popular type of housing is the square, as it is easier to make and therefore cheaper to produce. It is also the easier type of pump to operate, as it is easier to get an idea of how much pressure you are pumping out at any given time.

Vickers Hydraulic pumps are typically identified by the number of rows of vanes on the outer casing. This can be determined by looking at the number of rows of vanes on the exterior of the pump’s housing. Each row represents a different model, with each one having its own specific specifications and uses.

tags: {vickers vane pump identification,vickers hydraulic pump identification,vickers pump identification,old vickers vane pump identification,vickers vane loader pump identification,bmw e30 vickers powers steering pump identification,vickers single vane pump identification,vickers power steering pump identification,vickers gear pump identification}

2.The first is to identify the model number of the pump by measuring the diameter of the shaft and impeller shaft. The second is to measure whether it has a motormounted magnet or a motor-mounted magnet, and then measure the diameter of each vane shaft. If it is less than 24mm, then it is an old model; if it is larger than 24mm, then it must be a new model

1.The Vickers pump has a red cover and the Bosch has a blue cover. The Bosch pump is slightly larger than the Vickers pump in diameter, but not by much. So if you have a blue cover on your steering pump it may be a Bosch one.

2.The Bosch pumps have different numbers on them than the Vickers pumps do (at least they did when I was shopping). The Bosch number starts with “B” and then there is a number after that which indicates what year it was made for. The Vickers number starts with “V” and then there is another letter after that which indicates what year it was made for. For example: V-5-8 would indicate that it was made for an E30 from 1988-1989 or so on up until 1992-1993 or so when they switched to the M50 engine (which may have been discontinued earlier than this). V-7-0 would indicate that this was for an E30 M3 or 325iS or 325ix with the S14 engine (or similar models)

The single vane pumps are used for pumping fluids in closed circuits. The vanes seal against the casing and the volute, which is usually made of bronze, so that the fluid pressure forces them against these surfaces.

The Vickers power steering pump is an electrically driven pump, which provides the hydraulic pressure required to operate the power steering system. The pump may be replaced if it fails due to a malfunction or damage. The replacement process requires minimal tools and should only take about 15 minutes to complete.

Thank you for browsing our Vickers Hydraulic Pump Identification Guide. We hope that you found it helpful and that you were able to find the model of a hydraulic pump you are interested in. As with all products we carry, each pump is built with quality workmanship in mind and will serve you well for many years to come.

vickers <a href='https://www.ruidapetroleum.com/product/47'>hydraulic</a> <a href='https://www.ruidapetroleum.com/product/49'>pump</a> cross reference made in china

Established in 2010, developing fast in these years, now Shanghai Belle Hydraulic Co., Ltd has been expanding overseas markets to more than 30 countries including USA, Canada, England, Italy, Poland, Russia, Brazil, Peru, Argentina and Southeast Asian countries.

vickers <a href='https://www.ruidapetroleum.com/product/47'>hydraulic</a> <a href='https://www.ruidapetroleum.com/product/49'>pump</a> cross reference made in china

Filson’s wide range of Eaton/Internormen filter element replacement is designed to help you achieve oil cleanliness level requests when filtering hydraulic fluids, cooling lubricants or water-based fluids.

These Internormen exchange filter elements are offered with various filter materials, different construction types and micron ratings to protect your critical hydraulic system components and meet you any industrial applications.

vickers <a href='https://www.ruidapetroleum.com/product/47'>hydraulic</a> <a href='https://www.ruidapetroleum.com/product/49'>pump</a> cross reference made in china

Of the three primary hydraulic pump types — gear, vane, and piston — vane pumps offer flexibility in application, long life, quiet performance, and lower maintenance costs. Whether it’s time for repair or replacement, understanding old Vickers vane pump identification can save time and expense.

Originally developed nearly a century ago, the vane pump is a positive displacement device that uses centrifugal force on rotating vanes combined with under-vane pressure from the outlet port to cause the vanes to follow the elliptical inner surface of the cam ring.

Vane pumps also benefit from the ease of service. At Panagon Systems, we have found that most can be restored to a like-new performance by replacing just the vane cartridge kit without having to remove the unit from the application.

Once we finish the old Vickers vane pump identification, we can determine how best to service the equipment. For V10 and V20 models, the rotation of the pump can easily be reversed by opening the cover, removing the pressure plate and spring and flipping the cam ring.  We can also assess other performance issues that may be present.

As tribute to their durability, we have found that many early model pumps are still in service. Although sometimes we must examine a unit closely to find the model code, once Vickers vane pump identification is completed, we can learn everything needed for pump repair or replacement and evaluate if that model is still the right choice for the job.

In general, with old Vickers vane pump identification,  the V10 and V20 series are indicated at the second and third positions of the model code. Look for F3 code in the first position because it indicates the use of special O-rings or seals. However, an F3 code in the first position may be omitted if not required on that pump. In that case, the pump model should appear in the first position.

The second and third positions of the model code also designate the double pumps in the V2010 and V2020 series, with the same caveat for an F3 code in the first position. After that, the fourth position indicates the cover type, the fifth is the mounting type, and the sixth the mounting position of the foot bracket.

Further old Vickers vane pump identification reveals that with the V10 and V20 series, the seventh position indicates the rated ring capacity while on the V2010 and V2020, the seventh position designates a four-bolt flange at the inlet port. Also note that the eighth position on the V10 designates the size and thread type for outlet port connections, while the eighth position on the V20 model code indicates shaft type.

For mobile applications, look for a VTM and model number in the first and second positions. High-speed, high-pressure pumps are indicated by VQ after the model number.

Similar to earlier V10 and V20 models, the V series pumps are designated with the model number before the letter. On single pump models, higher numbers generally indicate greater displacement.

The Vickers V series double pumps, from 2520V through 4535V, and the thru-drive pump series, 25VT through 45VT, are selected for use in tight spaces or when a reduction in the number of motors and drive extensions is required.

Vickers vane pump identification also reveals the latest line-up from Eaton Vickers. The VMQ-series single and thru-drive pumps are designated VMQ1, double pumps are VMQ2 and triple pumps are VMQ3.