bakers pride safety valve free sample
ROBERTSHAW FMEA RETROFIT KIT COMMERCIAL GAS SAFETY VALVES includes valve with long button We were the first to market these kits when FMEA valves were discontinued
RETROFIT KIT FOR FMEA 1/2 INCHReplaces most 1/2 inch FMEA valvesIncludes• Adapter to convert pilot from 1/4 inch to 3/16 • one 1/2 TS11 VALVE• one brass extension • one 60" thermocouple• Fiberglass shield for thermocoupleThese kits will install in most situations without any additional hardware. In some cases it might be necessary to slightly enlarge hole on cover where button protrudes.
• Inlet outlet 1/2" NPT• Button length 1 3/32 "•Valve provides positive shut off of gas whenpilot is out •1/4" O.D. tubing outlet for pilot• For Bakers Pride deck pizza ovens model series 101, 104, 104P, 201,204, 204P, 251, 301, 304, 304P, 351, 401, 404, 404P, 451, 805, D125, Y600,Y612, X500, 922, 932 • Bakers Pride no. M1004A pilot is out
Double check valve assembly means an assembly composed of two single, independently acting, check valves including tightly closing shutoff valves located at each end of the assembly and suitable connections for testing the water tightness of each check valve.
Environmental, Health or Safety Requirements of Law means all Requirements of Law derived from or relating to foreign, federal, state and local laws or regulations relating to or addressing pollution or protection of the environment, or protection of worker health or safety, including, but not limited to, the Comprehensive Environmental Response, Compensation and Liability Act, 42 U.S.C. § 9601 et seq., the Occupational Safety and Health Act of 1970, 29 U.S.C. § 651 et seq., and the Resource Conservation and Recovery Act of 1976, 42 U.S.C. § 6901 et seq., in each case including any amendments thereto, any successor statutes, and any regulations or guidance promulgated thereunder, and any state or local equivalent thereof.
All gas operated Bakers Pride ® deck ovens are intended for use with the type of gas specified on the rating plate and for installation will be in accordance with National
This appliance must be installed by a competent person in accordance with the rules in force. In the U.K., Corgi registered installers (including the regions of British Gas) undertake to work to safe and satisfactory standards. This appliance must be installed in accordance with the current Gas Safety (Installation and Use) Regulations and the
(f ) The appliance must be isolated from the gas supply piping system by closing its manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2” psig (3.45kpa).
(g) The appliance and its shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system attest pressures in excess of 1/2” psig (3.45kpa).
Gas. If the oven is ordered for use on Propane Gas, the pressure regulator in the combination valve is preset at the factory to yield a pressure of 10” water column (25 mbar). Units for use on Propane Gas are not available for European Community Countries.
(i) A separate shut-off valve for each oven must be provided. It should be as close as possible to the place where the gas supply line goes into the oven.
The purpose of the safety pilot system is to lock the gas supply to the main burner at the combination valve, if for any reason the pilot burner is not lit. Oven should be
relighted by following the steps given below. However, in normal service, the pilot flame stays lit indefinitely, day and night or weekends. This prolongs the life of the safety valve.
The safety pilot valve is in effect a two-stage control. After initial lighting, the pilot burner stays on without the gas cock dial being held pressed in. After 1-2 minutes, the valve opens fully to let the gas flow past the safety pilot valve into the burner system.
If gas odor is detected at any time, immediately shut-off the gas supply valve for the oven. Do not permit any open flames in the area of the oven. Immediately contact an authorized Service Agency or your local Gas Supply Company.
(a) Deposits of baked-on splatter and grease, or discoloration may be removed with the stainless steel cleaner sample supplied or by using any commercial cleaner recommended for stainless steel. Bakers Pride offers a stainless steel cleaner expressly forth is purpose. RINSE WELL.
Baker"s Pride warrants to the original purchaser of new Baker"s Pride products to be free from defects in material or workmanship, under normal and proper use and maintenance service as specified by Bakers Pride and upon proper installation and start-up in accordance with the instructions supplied with each Bakers Pride unit. Baker"s Pride obligation under this warranty is limited to a period of one [1] year from the date of original installation, or eighteen [18] months from original invoice date, whichever occurs first. Defects that occur as a result of normal use, within the time period and limitations defined in this warranty, will at Baker"s Pride discretion have the parts replaced or repaired by Baker"s Pride or a Baker"s Pride-authorized service agency.
Repairs performed under this warranty are to be performed by an Bakers Pride authorized service agency. Baker"s Pride will not be responsible for charges incurred or service performed by nonauthorized repair agencies. In all cases, the nearest Baker"s Prideauthorized service agency must be used. Baker"s Pride will be responsible for normal labor charges incurred in the repair or replacement of a warrantied product within 50 miles (80.5 km) of an authorized service agency. Time and expense charges for anything beyond that distance will be the responsibility of the owner. All labor will need to be performed during regular service hours. Any overtime premium will be charged to the owner. For all shipments outside the U.S.A. and Canada, please see the International Warranty for specific details. It is the responsibility of the owner to inspect and report any shipping damage claims, hidden or otherwise, promptly following delivery. No mileage or travel charges will be honored on any equipment that is deemed portable.
Should you require any assistance regarding the operation or maintenance of any Baker"s Pride Manufacturing; phone or email our service department. In all correspondence provide the model number and serial number of the unit needing service; include the voltage or gas type. Normal Business Hours: 8:00 a.m. to 4:30 p.m. Central
Baker"s Pride sole obligation under this warranty is limited to either repair or replacement parts, subject to the additional limitations detailed below. This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty.
Any product which has not been used, maintained, or installed in accordance with the directions published in the appropriate installation sheet and/or owner’s manual, including incorrect gas or electrical connection. Baker"s Pride is not liable for any unit which has been mishandled, abused, misapplied, subjected to harsh chemicals, modified by unauthorized personnel, damaged by flood, fire, or other acts of nature [or God], or which have an altered or missing serial number.