wire rope isolator manufacturers free sample

IDC’s experienced engineering team has developed innovative isolator solutions for challenging applications and environments. We perform engineering, testing and manufacturing in the same facility, allowing us to offer customized solutions faster than most competitors. Whether you need a few samples or a large production run, we’ll work with you to achieve the most practical, cost-effective and highest-performing solution.

wire rope isolator manufacturers free sample

Wire rope isolators comprise helical steel cables threaded through high-strength retaining bars. These cable isolators deliver superior shock and vibration protection for sensitive equipment and products. With their durable construction, corrosion resistance and high-temperature tolerance, these isolation solutions are ideal for many applications across a broad industry range.

wire rope isolator manufacturers free sample

The vibration and noise emitting from the machines and equipment in operation may appear to be harmless on the surface. The people may get perturbed by the noise but may get used to working in the noisy industrial environment over a period of time. However, vibration and noise are the most destructive agents in the industrial environment and their effects are known in the form of machine breakdowns, fatigue failures, and health deterioration in human beings. By the time we realize these damages it is already too late. Products in the form of vibration wire rope isolators and rubber vibration dampening mounts are available today to stem the vibrations and prevent them from causing damage. Let us look at these products.

Wire cable isolators: The vibration isolation wire rope plays the crucial role in the selection of the right kind of isolator for the equipment. If you choose the right wire

characteristics like the wire diameter, number of strands, wire length, wire twist, and the number of strands per section you can get the wire isolator that is most suited for your requirement. Sufficient literature is available onsite to help you make this choice. It is right to call them as wire rope insulators as they shield the equipment from the harmful effects of vibration. As a passive vibration insulation system, the wire isolators require no maintenance, occupy little space, and perform even in changing temperature conditions and harsh environments.

Rubber mounts and isolators: The rubber mounts for vibrations are crucial components in the machinery and equipment, and help in dampening the noise levels and vibrations while safeguarding the sensitive parts from the impact of the external vibrations.

Rubber shock mounts: The shock mount type rubber vibration isolator is designed to absorb shock for static equipment. Another product in the rubber vibration isolation mounts category is suitable for the marine application such as propulsion engines and diesel generator sets where damping of low frequencies is required.

As a leading rubber mount manufacturer, Andre HVAC International Inc. has led the way to develop solutions to isolate vibrations and reduce noise over the past 13 years. They not only have a wide range of wire rope ISO mounts and rubber vibration isolation mountsbut also partner with you in developing a new application or capitalizing on their existing technology. You can be sure of finding the answer to your vibration damping needs from them.

wire rope isolator manufacturers free sample

About products and suppliers:Alibaba.com offers 312 wire rope isolators products. About 20% % of these are shock absorber, 7%% are other fabrication services, and 1%% are other rubber products.

A wide variety of wire rope isolators options are available to you, You can also choose from cross razor, wire rope isolators,As well as from energy & mining, manufacturing plant, and construction works . And whether wire rope isolators is online technical support, {2}, or {3}.

wire rope isolator manufacturers free sample

Our R&D work on GG Series All-Metal Wire Cable Vibration Isolator started in year 1983. In 1990, the product was listed as one of top national R&D achievements.

On top of the R&D work, we also took the leadership in making several military standard for electronic and marine industry, i.e., The General Specifications For All-Metal Wire Cable Vibration Isolator (SJ20593-96) and Specification For Wire-Cable Vibration Isolator Of Ships (GJB6412-2008),Which was published on 1st Octoboer.2008.

1,The product comes with softened non-linear stiffness, maximum dynamic displacement is over 70% of the valid space of isolator, dynamic stiffness decreases with the growth of displacement.

wire rope isolator manufacturers free sample

Commercial and defense aircraft manufacturers need to build planes that offer durable support for interior service equipment, while ensuring the quitest cabin possible. Overhead stowage bins and other structures need to accommodate changes in alignment whil...

Wire mesh material can be manufactured in a multitude of shapes and sizes to accommodate your specific application needs. Auxiliary Power Units (APUs) are just one example of a product that can benefit from the use of wire mesh technology. Its high damping ...

Small Vibration Mount offers Big Performance Use Enidine Compact Wire Rope Isolators for the best performance in vibration isolation and small vibration mount configurations. The compact design is smaller than most wire ropes and can provide both shock an...

High Performance Vibration Damping  Look to Enidine for high performance Wire Rope Isolators and Compact Wire Rope Isolators. The wire rope isolators have stainless steel cable and RoHS compliant aluminum retaining bars, which provides excellent vibration...

wire rope isolator manufacturers free sample

Wire rope isolator is one of the most effective isolation system that can be used to attenuate the vibration disturbances and shocks during the operation of machineries. This paper presents the results of investigation on static elastic stiffnesses (both in tension and in compression) of Polycal Wire Rope Isolator (PWRI) under quasi-static monotonic loading conditions. It also studied effect of variations in height and width of PWRI on its static stiffnesses. Suitable experimental setup was designed and manufactured to meet the test conditions. The results show that their elastic stiffnesses for both tension and compression loading conditions are highly influenced by their geometric dimensions. It is found that their compressive stiffness reduced by 55% for an increment of 20% in their height to width ratio. Therefore, the stiffness of PWRI can be fine-tuned by controlling their dimensions according to the requirements of the application.

.... Apparent deficiencies in this category are: (A) Visible broken wires, as follows: (1) In running wire ropes: Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope... around the rope. (2) In rotation resistant ropes: Two randomly distributed broken wires in six rope...

.... Apparent deficiencies in this category are: (A) Visible broken wires, as follows: (1) In running wire ropes: Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope... around the rope. (2) In rotation resistant ropes: Two randomly distributed broken wires in six rope...

.... Apparent deficiencies in this category are: (A) Visible broken wires, as follows: (1) In running wire ropes: Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope... around the rope. (2) In rotation resistant ropes: Two randomly distributed broken wires in six rope...

beneficial from the standpoint of wire - bending stress. How- ever, there is a design trade-off here in that the smaller L/d becomes, the lower are the...wires of a rope, it is first necessary to determine the radii of curvature of the wires prior to and after bending the rope. The wire - bending stress can... wire bending stress. 4.3. CONTACT STRESSES Contact stresses in a wire rope are one of the most important determinants of its fatigue life and are, by far

... 29 Labor 7 2011-07-01 2011-07-01 false Wire rope. 1919.79 Section 1919.79 Labor Regulations...) GEAR CERTIFICATION Certification of Shore-Based Material Handling Devices § 1919.79 Wire rope. (a) Wire rope and replacement wire rope shall be of the same size, same or better grade, and same construction...

... 29 Labor 7 2010-07-01 2010-07-01 false Wire rope. 1919.79 Section 1919.79 Labor Regulations...) GEAR CERTIFICATION Certification of Shore-Based Material Handling Devices § 1919.79 Wire rope. (a) Wire rope and replacement wire rope shall be of the same size, same or better grade, and same construction...

... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Wire ropes; scope. 77.1430 Section 77.1430... Hoisting Wire Ropes § 77.1430 Wire ropes; scope. (a) Sections 77.1431 through 77.1438 apply to wire ropes.... (b) These standards do not apply to wire ropes used for elevators. ...

... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Wire ropes; scope. 77.1430 Section 77.1430... Hoisting Wire Ropes § 77.1430 Wire ropes; scope. (a) Sections 77.1431 through 77.1438 apply to wire ropes.... (b) These standards do not apply to wire ropes used for elevators. ...

Passive dampers composed of coils of multi-strand wire rope are investigated. Analytical results range from those produced by complex NASTRAN models to those of a Coulomb damping model with variable friction force. The latter agrees well with experiment. The Coulomb model is also utilized to generate hysteresis loops. Various other models related to early experimental investigations are described. Significant closed-form static solutions for physical properties of single-and multi-strand wire ropes are developed for certain specific geometries and loading conditions. NASTRAN models concentrate on model generation and mode shapes of 2-strand and 7-strand straight wire ropes with interfacial forces.

... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Wire ropes; scope. 75.1430 Section 75.1430... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1430 Wire ropes; scope. (a) Sections 75.1430 through 75.1438 apply to wire ropes in service used to hoist— (1) Persons in...

... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Wire ropes; scope. 75.1430 Section 75.1430... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1430 Wire ropes; scope. (a) Sections 75.1430 through 75.1438 apply to wire ropes in service used to hoist— (1) Persons in...

... 29 Labor 7 2010-07-01 2010-07-01 false Proof tests-wire rope. 1919.33 Section 1919.33 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Persons § 1919.33 Proof tests—wire rope. Wire rope, except as provided in § 1919.14(b), shall be tested by...

... 29 Labor 7 2011-07-01 2011-07-01 false Proof tests-wire rope. 1919.33 Section 1919.33 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Persons § 1919.33 Proof tests—wire rope. Wire rope, except as provided in § 1919.14(b), shall be tested by...

Traction lifts are complex systems with rotating and translating moving masses, springs and dampers and several system inputs from the lifts and the users. The wire ropes are essential mechanical elements. The mechanical properties of the ropes in use depend on the rope construction, the load situation, nonlinearities and the lift dimensions. The mechanical properties are important for the proper use in lifts and the ride quality. But first of all the wire ropes (for all other suspension means as well) have to satisfy the safety relevant requirements sufficient lifetime, reliable determination of discard and sufficient and limited traction capacity. The lifetime of the wire ropes better the number of trips until rope discard depends on a lot of parameters of the rope and the rope application eg use of plastic deflection sheaves and reverse bending layouts. New challenges for rope lifetime are resulting from the more or less open D/d-ratio limits possible by certificates concerning the examination of conformity by notified bodies. This paper will highlight the basics of wire rope technology, the endurance and lifetime of wire ropes running over sheaves, and the different influences from the ropes and more and more important from the lift application parameters. Very often underestimated are the influences of transport, storage, installation and maintenance. With this background we will lead over to the calculation methods of wire rope lifetime considering the actual findings of wire rope endurance research. We"ll show in this paper new and innovative facts as the influence of rope length and size factor in the lifetime formular, the reduction of lifetime caused by traction grooves, the new model for the calculation in reverse bending operations and the statistically firmed possibilities for machine roomless lifts (MRL) under very small bending conditions.

... number of visible broken wires exceeds 10 percent of the total number of wires, or if the rope shows... 29 Labor 7 2012-07-01 2012-07-01 false Limitations on use of wire rope. 1919.24 Section 1919.24... on use of wire rope. (a) An eye splice made in any wire rope shall have at least three tucks with a...

... number of visible broken wires exceeds 10 percent of the total number of wires, or if the rope shows... 29 Labor 7 2013-07-01 2013-07-01 false Limitations on use of wire rope. 1919.24 Section 1919.24... on use of wire rope. (a) An eye splice made in any wire rope shall have at least three tucks with a...

... number of visible broken wires exceeds 10 percent of the total number of wires, or if the rope shows... 29 Labor 7 2014-07-01 2014-07-01 false Limitations on use of wire rope. 1919.24 Section 1919.24... on use of wire rope. (a) An eye splice made in any wire rope shall have at least three tucks with a...

... 29 Labor 7 2013-07-01 2013-07-01 false Proof tests-wire rope. 1919.33 Section 1919.33 Labor... Persons § 1919.33 Proof tests—wire rope. Wire rope, except as provided in § 1919.14(b), shall be tested by... acceptable to the Administration on the basis of design, shall not exceed one-fifth of the breaking load of...

... 29 Labor 7 2012-07-01 2012-07-01 false Proof tests-wire rope. 1919.33 Section 1919.33 Labor... Persons § 1919.33 Proof tests—wire rope. Wire rope, except as provided in § 1919.14(b), shall be tested by... acceptable to the Administration on the basis of design, shall not exceed one-fifth of the breaking load of...

... 29 Labor 7 2014-07-01 2014-07-01 false Proof tests-wire rope. 1919.33 Section 1919.33 Labor... Persons § 1919.33 Proof tests—wire rope. Wire rope, except as provided in § 1919.14(b), shall be tested by... acceptable to the Administration on the basis of design, shall not exceed one-fifth of the breaking load of...

... 29 Labor 8 2011-07-01 2011-07-01 false Wire rope-inspection. 1926.1413 Section 1926.1413 Labor... Wire rope—inspection. (a) Shift inspection. (1) A competent person must begin a visual inspection prior... inspection must consist of observation of wire ropes (running and standing) that are likely to be in use...

... 29 Labor 7 2011-07-01 2011-07-01 false Limitations on use of wire rope. 1919.24 Section 1919.24... on use of wire rope. (a) An eye splice made in any wire rope shall have at least three tucks with a... in the ends of wire rope cargo falls shall not be formed by knots and, in single part falls, shall...

... 29 Labor 7 2010-07-01 2010-07-01 false Limitations on use of wire rope. 1919.24 Section 1919.24... on use of wire rope. (a) An eye splice made in any wire rope shall have at least three tucks with a... in the ends of wire rope cargo falls shall not be formed by knots and, in single part falls, shall...

... 29 Labor 8 2011-07-01 2011-07-01 false Wire rope-selection and installation criteria. 1926.1414... Derricks in Construction § 1926.1414 Wire rope—selection and installation criteria. (a) Original equipment wire rope and replacement wire rope must be selected and installed in accordance with the requirements...

Wire rope transmission is very efficient because of the small total moving object mass. The wire rope could only transmit pulling force. Therefore it has to be kept in a tightened state during transmission; in high speed applications the dynamic performance depends on the rope"s stiffness, which can be adjusted by the wire rope tension. To improve the system dynamic performance output, this paper proposes a novel pull-pull method based on dual motors connected by wire ropes, for precise, high speed position control applications. The method can regulate target position and wire rope tension simultaneously. Wire ropes remain in a pre-tightening state at all times, which prevents the influence of elasticity and reduces the position tracking error in the changing direction process. Simulations and experiments were conducted; the results indicate that both position precision and superior dynamic performance can be synchronously achieved. The research is relevant to space craft precision pointing instruments.

... 46 Shipping 4 2010-10-01 2010-10-01 false Anchors, chains, wire rope, and hawsers. 108.705 Section... UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.705 Anchors, chains, wire rope, and hawsers. (a) Each unit must be fitted with anchors, chains, wire rope, and hawsers in agreement with the standards...

... 46 Shipping 4 2011-10-01 2011-10-01 false Anchors, chains, wire rope, and hawsers. 108.705 Section... UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.705 Anchors, chains, wire rope, and hawsers. (a) Each unit must be fitted with anchors, chains, wire rope, and hawsers in agreement with the standards...

Non-destructive testing on wire rope is in great demand to prevent safety accidents at sites where many heavy equipment using ropes are installed. In this paper, a research on quantification of magnetic flux leakage (MFL) signals were carried out to detect damages on wire rope. First, a simulation study was performed with a steel rod model using a finite element analysis (FEA) program. The leakage signals from the simulation study were obtained and it was compared for parameter: depth of defect. Then, an experiment on same conditions was conducted to verify the results of the simulation. Throughout the results, the MFL signal was quantified and a wire rope damage detection was then confirmed to be feasible. In further study, it is expected that the damage characterization of an entire specimen will be visualized as well.

A wire rope continuously variable transmissions (WR-CVT) has been introduced in the paper, in view of its less research, this paper mainly studied the stress distribution of 6×7+IWS bending wire rope. The results shown that the wire stress is layered distribution in each section, the stress at the outer strand center wire and outer strand side wire was the greatest, the stress value of the outer strand side wire and metal block circular notch is second. As the transmission ratio decreases, the wire stress decreases, which is related to the pulley working radius increases. Compared with the section A1, the stress value on the section A2 is smaller, mainly because the section A2 is not in contact with the metal block or the contact pressure is small. This study provides a basis for the study of fatigue and wears failure of WR-CVT components.

Three : - : strand : cable barriers were first developed in the 1960s and found to have several desirable : characteristics as compared to other roadside barriers such as guard rail : . : Brifen Wire Rope Safety Fence is : a four strand woven wire...

Steel wire ropes, which are usually composed of a polymer core and enclosed by twisted wires, are used to hoist heavy loads. These loads are different structures that can be clamshells, draglines, elevators, etc. Since the loading of these structures is dynamic, the ropes are working under fluctuating forces in a corrosive environment. This consequently leads to progressive loss of the metallic cross-section due to abrasion and corrosion. These defects can be seen in the forms of roughened and pitted surface of the ropes, reduction in diameter, and broken wires. Therefore, their deterioration must be monitored so that any unexpected damage or corrosion can be detected before it causes fatal accident. This is of vital importance in the case of passenger transportation, particularly in elevators in which any failure may cause a catastrophic disaster. At present, the widely used methods for thorough inspection of wire ropes include visual inspection and magnetic flux leakage (MFL). Reliability of the first method is questionable since it only depends on the operators" eyes that fails to determine the integrity of internal wires. The later method has the drawback of being a point by point and time-consuming inspection method. Ultrasonic guided wave (UGW) based inspection, which has proved its capability in inspecting plate like structures such as tubes and pipes, can monitor the cross-section of wire ropes in their entire length from a single point. However, UGW have drawn less attention for defect detection in wire ropes. This paper reports the condition monitoring of a steel wire rope from a hoisting elevator with broken wires as a result of corrosive environment and fatigue. Experiments were conducted to investigate the efficiency of using magnetostrictive based UGW for rope defect detection. The obtained signals were analyzed by two time-frequency representation (TFR) methods, namely the Short Time Fourier Transform (STFT) and the Wavelet analysis. The location of

A wire rope continuously variable transmissions (WR-CVT) has been introduced in the paper, in view of its less research, this paper mainly studied the deformation distribution of 6×7+IWS bending wire rope. The results shown that in the same section, half of the side strands are in a stretched state and half are in a compressed state. When the transmission ratio i=2.35, the maximum deformation and the minimum deformation are decrease when section U1 to U2, U3 transition. Wire deformation distribution when the transmission ratio i=0.42 is similar to that of i=0.2.35. Wire deformation amount and the deformation difference decrease as the transmission ratio decreases, this shows that the increase in the bending radius of the wire will make the wire deformation more uniform, and the reduction of the deformation difference will also reduce the wear. This study provides a basis for the study of fatigue and wears failure of WR-CVT components.

On January 6, 2016 at El Paso, the Guppy winch motor was changed. After completion of the operational checks, the load bar was being reinstalled on the cargo pallet when the motor control FORWARD relay failed in the energized position. The pallet was pinned at all locations (each pin has a load capacity of 16,000 lbs.) while the winch was running. The wire rope snapped before aircraft power could be removed. After disassembly, the fractured wire rope was shipped to ES4 lab for further characterization of the wire rope portion of the failure. The system was being operated without a clear understanding of the system capability and function. The proximate cause was the failure of the K48 -Forward Winch Control Relay in the energized position, which allowed the motor to continuously run without command from the hand controller, and operation of the winch system with both controllers connected to the system. This prevented the emergency stop feature on the hand controller from functioning as designed. An electrical checkout engineering work instruction was completed and identified the failed relay and confirmed the emergency stop only paused the system when the STOP button on both connected hand controllers were depressed simultaneously. The winch system incorporates a torque limiting clutch. It is suspected that the clutch did not slip and the motor did not stall or overload the current limiter. Aircraft Engineering is looking at how to change the procedures to provide a checkout of the clutch and set to a slip torque limit appropriate to support operations.

This paper concerns wire rope tension control of a double-rope winding hoisting system (DRWHS), which consists of a hoisting system employed to realize a transportation function and an electro-hydraulic servo system utilized to adjust wire rope tensions. A dynamic model of the DRWHS is developed in which parameter uncertainties and external disturbances are considered. A comparison between simulation results using the dynamic model and experimental results using a double-rope winding hoisting experimental system is given in order to demonstrate accuracy of the dynamic model. In order to improve the wire rope tension coordination control performance of the DRWHS, a robust nonlinear adaptive backstepping controller (RNABC) combined with a nonlinear disturbance observer (NDO) is proposed. Main features of the proposed combined controller are: (1) using the RNABC to adjust wire rope tensions with consideration of parameter uncertainties, whose parameters are designed online by adaptive laws derived from Lyapunov stability theory to guarantee the control performance and stability of the closed-loop system; and (2) introducing the NDO to deal with uncertain external disturbances. In order to demonstrate feasibility and effectiveness of the proposed controller, experimental studies have been conducted on the DRWHS controlled by an xPC rapid prototyping system. Experimental results verify that the proposed controller exhibits excellent performance on wire rope tension coordination control compared with a conventional proportional-integral (PI) controller and adaptive backstepping controller. Copyright © 2017 ISA. All rights reserved.

A nondestructive detection system based on X-ray for wire ropes conveyer belt is designed by X-ray detection technology. In this paper X-ray detection principle is analyzed, a design scheme of the system is presented; image processing of conveyer belt is researched and image processing algorithms are given; X-ray acquisition receiving board is designed with the use of FPGA and DSP; the software of the system is programmed by C#.NET on WINXP/WIN2000 platform. The experiment indicates the system can implement remote real-time detection of wire ropes conveyer belt images, find faults and give an alarm in time. The system is direct perceived, strong real-time and high accurate. It can be used for fault detection of wire ropes conveyer belts in mines, ports, terminals and other fields.

A dual energy X-ray detector for conveyor belt with steel wire ropes is researched in the paper. Conveyor belt with steel wire ropes is one of primary transfer equipments in modern production. The traditional test methods like electromagnetic induction principle could not display inner image of steel wire ropes directly. So X-ray detection technology has used to detect the conveyor belt. However the image was not so clear by the interference of the rubber belt. Therefore, the dualenergy X-ray detection technology with subtraction method is developed to numerically remove the rubber belt from radiograph, thus improving the definition of the ropes image. The purpose of this research is to design a dual energy Xray detector that could make the operator easier to found the faulty of the belt. This detection system is composed of Xray source, detector controlled by FPGA chip, PC for running image processing system and so on. With the result of the simulating, this design really improved the capability of the staff to test the conveyor belt.

View of main hoist wire rope drum and brakes, open contact boards are in view at the far right wall - Puget Sound Naval Shipyard, Portal Gantry Crane No. 42, Pier 5, Farragut Avenue, Bremerton, Kitsap County, WA

... plow steel wire rope and wire rope slings with various types of terminals. For sizes, classifications... than five (5) is maintained. (b) Wire rope and wire rope slings. (1) Tables G-2 through G-5 in § 1915... blunted. (3) Where U-bolt wire rope clips are used to form eyes, Table G-6 in § 1915.118 shall be used to...

... plow steel wire rope and wire rope slings with various types of terminals. For sizes, classifications... than five (5) is maintained. (b) Wire rope and wire rope slings. (1) Tables G-2 through G-5 in § 1915... blunted. (3) Where U-bolt wire rope clips are used to form eyes, Table G-6 in § 1915.118 shall be used to...

An X-ray nondestructive detector for high-speed running conveyor belt with steel wire ropes is researched in the paper. The principle of X-ray nondestructive testing (NDT) is analyzed, the general scheme of the X-ray nondestructive testing system is proposed, and the nondestructive detector for high-speed running conveyor belt with steel wire ropes is developed. The hardware of system is designed with Xilinx"s VIRTEX-4 FPGA that embeds PowerPC and MAC IP core, and its network communication software based on TCP/IP protocol is programmed by loading LwIP to PowerPC. The nondestructive testing of high-speed conveyor belt with steel wire ropes and network transfer function are implemented. It is a strong real-time system with rapid scanning speed, high reliability and remotely nondestructive testing function. The nondestructive detector can be applied to the detection of product line in industry.

Rapid development of steel wire rope industry has led to the generation of large quantities of pickling sludge, which causes significant ecological problems and considerable negative environmental effects. In this study, a novel method was proposed for harmless disposal and resource reutilization of the steel wire rope sludge. Based on the method, two steel wire rope sludges (the Pb sludge and the Zn sludge) were firstly extracted by hydrochloric or sulfuric acid and then mixed with the hydrochloride acid extracting solution of aluminum skimmings to produce composite polyaluminum ferric flocculants. The optimum conditions (acid concentration, w/v ratio, reaction time, and reaction temperature) for acid extraction of the sludges were studied. Results showed that 97.03 % of Pb sludge and 96.20 % of Zn sludge were extracted. Leaching potential of the residues after acid extraction was evaluated, and a proposed treatment for the residues had been instructed. The obtained flocculant products were used to purify the real domestic wastewater and showed an equivalent or better performance than the commercial ones. This method is environmental-friendly and cost-effective when compared with the conventional sludge treatments.

Most traditional strong magnetic inspection equipment has disadvantages such as big excitation devices, high weight, low detection precision, and inconvenient operation. This paper presents the design of a giant magneto-resistance (GMR) sensor array collection system. The remanence signal is collected to acquire two-dimensional magnetic flux leakage (MFL) data on the surface of wire ropes. Through the use of compressed sensing wavelet filtering (CSWF), the image expression of wire ropes MFL on the surface was obtained. Then this was taken as the input of the designed back propagation (BP) neural network to extract three kinds of MFL image geometry features and seven invariant moments of defect images. Good results were obtained. The experimental results show that nondestructive inspection through the use of remanence has higher accuracy and reliability compared with traditional inspection devices, along with smaller volume, lighter weight and higher precision.

by " braiding " or "weaving" one rope end into another. Splices may be made at the end of a single rope after forming a loop (an eye splice) or between...rags, large pieces of old hemp rope and fire hose are other popular types of chafing gear for semi-fixed position ropes (see Figure 7-3(b)). 7.4. LINKS...Figure 7-3. Chafing Gear 7-6 Links 7.4. SWOOD PLANK FIRE HOSE ., ’ _APPLY GREASE CANJVAS, LEATHER, COPPER (b) For Semi-Fixed Position Ropes lo- Figcre

Electromagnetic methods are commonly employed to detect wire rope discontinuities. However, determining the residual strength of wire rope based on the quantitative recognition of discontinuities remains problematic. We have designed a prototype device based on the residual magnetic field (RMF) of ferromagnetic materials, which overcomes the disadvantages associated with in-service inspections, such as large volume, inconvenient operation, low precision, and poor portability by providing a relatively small and lightweight device with improved detection precision. A novel filtering system consisting of the Hilbert-Huang transform and compressed sensing wavelet filtering is presented. Digital image processing was applied to achieve the localization and segmentation of defect RMF images. The statistical texture and invariant moment characteristics of the defect images were extracted as the input of a radial basis function neural network. Experimental results show that the RMF device can detect defects in various types of wire rope and prolong the service life of test equipment by reducing the friction between the detection device and the wire rope by accommodating a high lift-off distance. PMID:28300790

Most traditional strong magnetic inspection equipment has disadvantages such as big excitation devices, high weight, low detection precision, and inconvenient operation. This paper presents the design of a giant magneto-resistance (GMR) sensor array collection system. The remanence signal is collected to acquire two-dimensional magnetic flux leakage (MFL) data on the surface of wire ropes. Through the use of compressed sensing wavelet filtering (CSWF), the image expression of wire ropes MFL on the surface was obtained. Then this was taken as the input of the designed back propagation (BP) neural network to extract three kinds of MFL image geometry features and seven invariant moments of defect images. Good results were obtained. The experimental results show that nondestructive inspection through the use of remanence has higher accuracy and reliability compared with traditional inspection devices, along with smaller volume, lighter weight and higher precision. PMID:27571077

This research demonstrated the feasibility of supplying approximately 1 watt of electrical power for one year on the sea bed with a novel battery, the rope battery. The proposed battery would look very much like a small diameter wire rope, possibly hundreds of feet long. This unusual shape permits the rope battery to take full advantage of the vastness of the ocean floor and permits at great pressure the steady diffusion of reaction products away from the battery itself. A sea water battery is described consisting of an inner bundle of coated wires which slowly corrode and an outer layer of fine wires which simultaneously provides strength, armor and surface area for slow hydrogen evolution. Two variations are examined. The fuse utilizes magnesium wires and burns slowly from the end. The rope utilizes lithium-zinc alloys and is slowly consumed along its entire length.

A partnership is described that was formed as a result of a NASA university grant for the study of wire rope vibration isolation systems. Vibration isolators of this type are currently used in the Space Shuttle Orbiter and engine test facility, and have potential application in the international space station and other space vehicles. Wire rope isolators were considered for use on the Hubble Space Telescope and the military has used wire rope technology extensively. The desire of the wire rope industry to expand sales in commercial markets coupled with results of the prior NASA funded study, led to the formation of a partnership including NASA, the university involved in the research grant, and a small company that designs wire rope systems. Goals include the development of improved mathematical models and a designers handbook to facilitate the use of the new modeling tools.

National Aeronautics and Space Administration (NASA) uses exercise countermeasures on the International Space Station (ISS) to maintain crew health and combat the negative effects of long-duration spaceflight on the human body. Most ISS exercise countermeasures system (CMS) equipment rely heavily on the use of textile and wire ropes to transmit resistive loads and provide stability in a microgravity environment. For a variety of reasons, including challenges in simulating microgravity environments for testing and limits on time available for life cycle testing, the textiles and wire ropes have contributed significantly to on-orbit planned and unplanned maintenance time. As a result, continued ground testing and on-orbit experience since the first expedition on the ISS in 2000 provide valuable data and lessons learned in materials selection, applications, and design techniques to increase service life of these ropes. This paper will present a review of the development and failure history of textile and wire ropes for four exercise countermeasure systems-the Treadmill with Vibration Isolation and Stabilization (TVIS) System, Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) System, Interim Resistive Exercise Device (IRED), and the Advanced Resistive Exercise Device (ARED)-to identify lessons learned in order to improve future systems. These lessons learned, paired with thorough testing on the ground, offer a forward path towards reduced maintenance time and up-mass for future space missions.

In this study, a magnetic flux leakage (MFL) method, known to be a suitable non-destructive evaluation (NDE) method for continuum ferromagnetic structures, was used to detect local damage when inspecting steel wire ropes. To demonstrate the proposed damage detection method through experiments, a multi-channel MFL sensor head was fabricated using a Hall sensor array and magnetic yokes to adapt to the wire rope. To prepare the damaged wire-rope specimens, several different amounts of artificial damages were inflicted on wire ropes. The MFL sensor head was used to scan the damaged specimens to measure the magnetic flux signals. After obtaining the signals, a series of signal processing steps, including the enveloping process based on the Hilbert transform (HT), was performed to better recognize the MFL signals by reducing the unexpected noise. The enveloped signals were then analyzed for objective damage detection by comparing them with a threshold that was established based on the generalized extreme value (GEV) distribution. The detected MFL signals that exceed the threshold were analyzed quantitatively by extracting the magnetic features from the MFL signals. To improve the quantitative analysis, damage indexes based on the relationship between the enveloped MFL signal and the threshold value were also utilized, along with a general damage index for the MFL method. The detected MFL signals for each damage type were quantified by using the proposed damage indexes and the general damage indexes for the MFL method. Finally, an artificial neural network (ANN) based multi-stage pattern recognition method using extracted multi-scale damage indexes was implemented to automatically estimate the severity of the damage. To analyze the reliability of the MFL-based automated wire rope NDE method, the accuracy and reliability were evaluated by comparing the repeatedly estimated damage size and the actual damage size.

The imperative need to protect structures in mountainous areas against rockfall has led to the development of various protection methods. This study introduces a new type of rockfall protection fence made of posts, wire ropes, wire netting and energy absorbers. The performance of this rock fence was verified in both experiments and dynamic finite element analysis. In collision tests, a reinforced-concrete block rolled down a natural slope and struck the rock fence at the end of the slope. A specialized system of measuring instruments was employed to accurately measure the acceleration of the block without cable connection. In particular, the performance of two energy absorbers, which contribute also to preventing wire ropes from breaking, was investigated to determine the best energy absorber. In numerical simulation, a commercial finite element code having explicit dynamic capabilities was employed to create models of the two full-scale tests. To facilitate simulation, certain simplifying assumptions for mechanical data of each individual component of the rock fence and geometrical data of the model were adopted. Good agreement between numerical simulation and experimental data validated the numerical simulation. Furthermore, the results of numerical simulation helped highlight limitations of the testing method. The results of numerical simulation thus provide a deeper understanding of the structural behavior of individual components of the rock fence during rockfall impact. More importantly, numerical simulations can be used not only as supplements to or substitutes for full-scale tests but also in parametric study and design.

New ultra-high molecular weight polyethylene rope has shown good results as a replacement for wire rope in logging applications in the western United States. A single case study trial was performed in Appalachian forest conditions to assess the appropriateness of this technology for hardwood logging applications. The study focused on use of the rope in West Virginia...

NSWC TR 85-388 EVALUATION OF THE LMATM SERIES OF WIRE N ROPE TESTING INSTRUMENTS N BY PAUL M. GAMMELL (NSWC) LARRY D. UNDERBAKKE (NCEL) RESEARCH AND...TECHNOLOGY DEPARTMENT 30 SEPTEMBER 1985’ < DTIC l LECTE Aji~p ro t lu f j t) I c rv I o. s ( st rhtI IiT oi i ts n m itedi1 8 1 JON- NAVAL SURFACE...AUTHOR(S) Gammell, Paul M. (NSWC) and Underbakke, Larry D. (NCEL) 13a. TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT (Year, Month, Day) S. PAGE

This paper mainly introduces a device for controlling prestress and its related research methods, the advantage of this method is that the reinforcement process is easy to operate and control the prestress of wire rope accurately. The relationship between the stress and strain of the steel wire rope is monitored during the experiment, and the one - to - one relationship between the controllable position and the pretightening force of the steel wire rope is confirmed by the 5mm steel wire rope, and the results are analyzed theoretically by the measured elastic modulus. The results show that the method can effectively control the prestressing force, and the result provides a reference method for strengthening the concrete column with prestressed steel strand.

... sockets must be attached to the unloaded dead end of the rope only, except that the use of devices specifically designed for dead-ending rope in a wedge socket is permitted. (g) Socketing must be done in the...

... sockets must be attached to the unloaded dead end of the rope only, except that the use of devices specifically designed for dead-ending rope in a wedge socket is permitted. (g) Socketing must be done in the...

... sockets must be attached to the unloaded dead end of the rope only, except that the use of devices specifically designed for dead-ending rope in a wedge socket is permitted. (g) Socketing must be done in the...

This article presents a lesson plan that uses materials such as rope, drinking water, and straws in a classroom activity to teach elementary students about electrical circuits in a "hands on/minds on" fashion. Students first experiment with bulbs, wires, and switches, then they do an activity with simulating electricity through a circuit…

This study is concerned with the theoretical modelling and experimental verification of the coupled vibrations of building and elevator ropes. The elevator ropes consist of a main rope which supports the cage and the compensation rope which is connected to the compensation sheave. The elevator rope is a flexible wire with a low damping, so it is prone to vibrations. In the case of a high-rise building, the rope length also increases significantly, so that the fundamental frequency of the elevator rope approaches the fundamental frequency of the building thus increasing the possibility of resonance. In this study, the dynamic model for the analysis of coupled vibrations of building and elevator ropes was derived by using Hamilton"s principle, where the cage motion was also considered. An experimental testbed was built to validate the proposed dynamic model. It was found that the experimental results are in good agreement with the theoretical predictions thus validating the proposed dynamic model. The proposed model was then used to predict the vibrations of real building and elevator ropes.

The aim of this study was to address the inconsistency regarding the operative treatment of Rockwood type III acromioclavicular joint separation. We compared results after single- and double TightRope ® reduction with results after acromioclavicular transfixation via K-wires only and additional ligament augmentation in acute acromioclavicular (AC) joint separations graded Rockwood type III, and hypothesized that the TightRope ® technique leads to better clinical and radiological results. We conducted a retrospective clinical cohort study and included 42 consecutive patients (mean age 43 years [24-66]) diagnosed and operatively treated between 2004 and 2012 (mean follow-up was 54.6 months [15-118]). Specific shoulder scores as well as scores reflecting the patients" overall mental and physical health status were used. Radiological evaluation was also performed. The SF12 test revealed comparability between all subgroups. Specific shoulder tests and a visual analogue scale demonstrated comparable results. Radiographic measurements showed a significant reduction in the AC distance and CC distance after surgery in all subgroups. The early complication rate was 9.5% for all patients, while late complications occurred in 14.3% of all cases. Compared to the established methods, the operative TightRope ® procedures represent a safe alternative in Rockwood III injuries. All investigated techniques predominantly led to good and excellent clinical results in acute Rockwood type III AC joint instabilities. Avoidance of material removal and shorter hospital stays appear to speak in favour for the TightRope ® technique. IV. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

Improving the reliability of modern turbine engines is actual task. This is achieved due to prevent a vibration damage of the operating blades. On the department of structure and design of aircraft engines have accumulated a lot of experimental data on the protection of the blades of the gas turbine engine from a vibration. In this paper we proposed a method for calculating the characteristics of wire rope dampers in the root attachment of blade of a gas turbine engine. The method is based on the use of the finite element method and transient analysis. Contact interaction (Lagrange-Euler method) between the compressor blade and the disc of the rotor has been taken into account. Contribution of contact interaction between details in damping of the system was measured. The proposed method provides a convenient way for the iterative selection of the required parameters the wire rope elastic-damping element. This element is able to provide the necessary protection from the vibration for the blade of a gas turbine engine.

The Stratospheric Aerosol and Gas Experiment (SAGE) III - International Space Station (ISS) instrument will be used to study ozone, providing global, long-term measurements of key components of the Earth"s atmosphere for the continued health of Earth and its inhabitants. SAGE III is launched into orbit in an inverted configuration on SpaceX;s Falcon 9 launch vehicle. As one of its four supporting elements, a Contamination Monitoring Package (CMP) mounted to the top panel of the Interface Adapter Module (IAM) box experiences high-frequency response due to structural coupling between the two structures during the SpaceX launch. These vibrations, which were initially observed in the IAM Engineering Development Unit (EDU) test and later verified through finite element analysis (FEA) for the SpaceX launch loads, may damage the internal electronic cards and the Thermoelectric Quartz Crystal Microbalance (TQCM) sensors mounted on the CMP. Three-dimensional (3D) vibration isolators were required to be inserted between the CMP and IAM interface in order to attenuate the high frequency vibrations without resulting in any major changes to the existing system. Wire rope isolators were proposed as the isolation system between the CMP and IAM due to the low impact to design. Most 3D isolation systems are designed for compression and roll, therefore little dynamic data was available for using wire rope isolators in an inverted or tension configuration. From the isolator FEA and test results, it is shown that by using the 3D wire rope isolators, the CMP high-frequency responses have been suppressed by several orders of magnitude over a wide excitation frequency range. Consequently, the TQCM sensor responses are well below their qualification environments. It is indicated that these high-frequency responses due to the typical instrument structural coupling can be significantly suppressed by a vibration passive control using the 3D vibration isolator. Thermal and contamination

An electrical wire is reported along whose length loops are formed at intervals and retained in a plastic capsule that allows unfolding of the loop when tension is exerted on the opposite ends of the wire. The capsule is formed by encompassing each loop with a sleeve of heat shrinkable synthetic plastic material which overlaps the loop and heat shrinking the overlapping portions. Thus, a length of electrical wire is formed which stores extra lengths of wire in the quantity needed to match the expected stretching of materials or elements such as ropes, cords and the like of high elongation to which the electrical wire may be attached.

The NASA Orion Multi-Purpose Crew Vehicle (MPCV) is being designed to replace the Space Shuttle as the main manned spacecraft for the agency. Based on the predicted environments in the Service Module avionics ring, an isolation system was deemed necessary to protect the avionics packages carried by the spacecraft. Impact, sinusoidal, and random vibration testing were conducted on a prototype Orion Service Module avionics pallet in March 2010 at the NASA Glenn Research Center Structural Dynamics Laboratory (SDL). The pallet design utilized wire rope isolators to reduce the vibration levels seen by the avionics packages. The current pallet design utilizes the same wire rope isolators (M6-120-10) that were tested in March 2010. In an effort to save cost and schedule, the Finite Element Models of the prototype pallet tested in March 2010 were correlated. Frequency Response Function (FRF) comparisons, mode shape and frequency were all part of the correlation process. The non-linear behavior and the modeling the wire rope isolators proved to be the most difficult part of the correlation process. The correlated models of the wire rope isolators were taken from the prototype design and integrated into the current design for future frequency response analysis and component environment specification.

seawater. The principal effect of crevices on the corrosion of zinc- or aluminum - coated or uncoated steel rope is to entrap corrosive liquids and...visual inspection of the rope surface. j 5. The effect of stresses, such as tensile, bending, torsion , and comn- pression, upon rope in service is not...questionable A value. d. The effect of stresses, such as tensile, bending, torsion , and compressive contact, on rope is not understood well. 2

In a recent paper, the relation between current sheet, magnetic reconnection, and turbulence at the leading edge of an interplanetary coronal mass ejection was studied. We report here the observation of magnetic reconnection at the interface region of two interplanetary magnetic flux ropes. The front and rear boundary layers of three interplanetary magnetic flux ropes are identified, and the structures of magnetic flux ropes are reconstructed by the Grad Shafranov method. A quantitative analysis of the reconnection condition and the degree of intermittency reveals that rope-rope magnetic reconnection is the most likely site for genesis of interplanetary intermittency turbulence in this event. The dynamic pressure pulse resulting from this reconnection triggers the onset of a geomagnetic storm.

One popular activity within physical education curricula today is jump rope. Jump rope is recognized as an excellent activity for developing motor skills and the affective domain, and it aligns with several recommended outcomes for physical education listed by the SHAPE America--Society of Health and Physical Educators. This article describes…

... Improved Plow Steel, Independent Wire Rope Core, Wire Rope and Wire Rope Slings [In tons of 2,000 pounds... for Improved Plow Steel, Independent Wire Rope Core, Wire Rope Slings [in tons of 2,000 pounds] Two...-4—Rated Capacities for Improved Plow Steel, Fiber Core, Wire Rope and Wire Rope Slings [in tons of 2...

... Improved Plow Steel, Independent Wire Rope Core, Wire Rope and Wire Rope Slings [In tons of 2,000 pounds... for Improved Plow Steel, Independent Wire Rope Core, Wire Rope Slings [in tons of 2,000 pounds] Two...-4—Rated Capacities for Improved Plow Steel, Fiber Core, Wire Rope and Wire Rope Slings [in tons of 2...

Flux-ropes are usually associated with magnetic structures embedded in the interplanetary Coronal Mass Ejections (ICMEs) with a depressed proton temperature (called Magnetic Clouds, MCs). However, small-scale flux-ropes in the solar wind are also identified with different formation, evolution, and dynamic involved. We present an analytical model to describe magnetic flux-rope topologies. The model is generalized to different grades of complexity. It extends the circular-cylindrical concept of Hidalgo et al. (2002) by introducing a general form for the radial dependence of the current density. This generalization provides information on the force distribution inside the flux rope in addition to the usual parameters of flux-rope geometrical information and orientation. The generalized model provides flexibility for implementation in 3-D MHD simulations.

This cross-disciplinary special issue on "Self-organization in magnetic flux ropes" follows in the footsteps of another collection of manuscripts dedicated to the subject of magnetic flux ropes, a volume on "Physics of magnetic flux ropes" published in the American Geophysical Union"s Geophysical Monograph Series in 1990 [1]. Twenty-four years later, this special issue, composed of invited original contributions highlighting ongoing research on the physics of magnetic flux ropes in astrophysical, space and laboratory plasmas, can be considered an update on our state of understanding of this fundamental constituent of any magnetized plasma. Furthermore, by inviting contributions from research groups focused on the study of the origins and properties of magnetic flux ropes in a variety of different environments, we have attempted to underline both the diversity of and the commonalities among magnetic flux ropes throughout the solar system and, indeed, the universe. So, what is a magnetic flux rope? The answer will undoubtedly depend on whom you ask. A flux rope can be as narrow as a few Larmor radii and as wide as the Sun (see, e.g., the contributions by Heli Hietala et al and by Angelous Vourlidas). As described below by Ward Manchester IV et al , they can stretch from the Sun to the Earth in the form of interplanetary coronal mass ejections. Or, as in the Swarthmore Spheromak Experiment described by David Schaffner et al , they can fit into a meter-long laboratory device tended by college students. They can be helical and line-tied (see, e.g., Walter Gekelman et al or J Sears et al ), or toroidal and periodic (see, e.g., John O"Bryan et al or Philippa Browning et al ). They can form in the low plasma beta environment of the solar corona (Tibor Török et al ), the order unity beta plasmas of the solar wind (Stefan Eriksson et al ) and the plasma pressure dominated stellar convection zones (Nicholas Nelson and Mark Miesch). In this special issue, Setthivoine You

Two types of white wheat bread (high- and low-type loaves) were investigated for rope spoilage. Thirty of the 56 breads tested developed rope spoilage within 5 days; the high-type loaves were affected by rope spoilage more than the low-type loaves. Sixty-one Bacillus strains were isolated from ropy breads and were characterized on the basis of their phenotypic and genotypic traits. All of the isolates were identified as Bacillus subtilis by biochemical tests, but molecular assays (randomly amplified polymorphic DNA PCR assay, denaturing gradient gel electrophoresis analysis, and sequencing of the V3 region of 16S ribosomal DNA) revealed greater Bacillus species variety in ropy breads. In fact, besides strains of B. subtilis, Bacillus licheniformis, Bacillus cereus, and isolates of Bacillus clausii and Bacillus firmus were also identified. All of the ropy Bacillus isolates exhibited amylase activity, whereas only 32.4% of these isolates were able to produce ropiness in bread slices after treatment at 96 degrees C for 10 min. Strains of lactic acid bacteria previously isolated from sourdough were first selected for antirope activity on bread slices and then used as starters for bread-making experiments. Prevention of growth of approximately 10(4) rope-producing B. subtilis G1 spores per cm(2) on bread slices for more than 15 days was observed when heat-treated cultures of Lactobacillus plantarum E5 and Leuconostoc mesenteroides A27 were added. Growth of B. subtilis G1 occurred after 7 days in breads started with Saccharomyces cerevisiae T22, L. plantarum E5, and L. mesenteroides A27.

The present work encompasses papers on the structure, waves, and instabilities of magnetic flux ropes (MFRs), photospheric flux tubes (PFTs), the structure and heating of coronal loops, solar prominences, coronal mass ejections and magnetic clouds, flux ropes in planetary ionospheres, the magnetopause, magnetospheric field-aligned currents and flux tubes, and the magnetotail. Attention is given to the equilibrium of MFRs, resistive instability, magnetic reconnection and turbulence in current sheets, dynamical effects and energy transport in intense flux tubes, waves in solar PFTs, twisted flux ropes in the solar corona, an electrodynamical model of solar flares, filament cooling and condensation in a sheared magnetic field, the magnetopause, the generation of twisted MFRs during magnetic reconnection, ionospheric flux ropes above the South Pole, substorms and MFR structures, evidence for flux ropes in the earth magnetotail, and MFRs in 3D MHD simulations.

Detail of conning tower atop the submarine. Note the wire rope wrapped around the base of the tower, which may have been used in an attempt to pull the submarine offshore. - Sub Marine Explorer, Located along the beach of Isla San Telmo, Pearl Islands, Isla San Telmo, Former Panama Canal Zone, CZ

... and Spacing of U-Bolt Wire Rope Clips Improved plow steel, rope diameter (inches/(cm)) Minimum number.... (b) Wire rope and wire rope slings. (1) The employer shall ascertain and adhere to the manufacturer"s recommended ratings for wire rope and wire rope slings and shall have such ratings available for inspection...

During the recent ISEE-3 Geotail Mission three events have been identified from the magnetometer data which are consistent with a spacecraft crossing of a magnetotail flux rope. Energetic electron and proton observations obtained by the Max-Planck-Institut/University of Maryland sensor system during two of the possible flux rope events are presented. During one event remote sensing of the flux rope with energetic protons reveals that the flux rope is crossed by the spacecraft from south to north. This allows determination of the bandedness of the magnetic field twist and of the flux rope velocity relative to the spacecraft. A minimal flux rope radius of 3 earth radii is derived. Energetic proton intensity is highest just inside of the flux rope and decreases towards the core. Energetic electrons are streaming tailward near the outer boundary, indicating openness of the field lines, and are isotropic through the inner part of the flux rope.

...=Static Load×4.0 (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0-0.0005L) For rope lengths 4,000 feet or greater: Minimum Value=Static Load×5.0 (c) Tail ropes....19021 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL...

...=Static Load×4.0 (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0-0.0005L) For rope lengths 4,000 feet or greater: Minimum Value=Static Load×5.0 (c) Tail ropes....19021 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL...

...) For rope lengths 3,000 feet or greater: Minimum Value=Static Load×4.0 (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0−0.0005L) For rope lengths 4,000 feet... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH...

...) For rope lengths 3,000 feet or greater: Minimum Value=Static Load×4.0 (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0−0.0005L) For rope lengths 4,000 feet... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH...

...=Static Load×4.0 (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0−0.0005L) For rope lengths 4,000 feet or greater: Minimum Value=Static Load×5.0 (c) Tail ropes... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH...

...=Static Load×4.0 (b) Friction drum ropes. For rope lengths less than 4,000 feet: Minimum Value=Static Load×(7.0−0.0005L) For rope lengths 4,000 feet or greater: Minimum Value=Static Load×5.0 (c) Tail ropes... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH...

We describe a geometrical property of helical structures and show how it accounts for the early art of rope-making. Helices have a maximum number of rotations that can be added to them — and it is shown that this is a geometrical feature, not a material property. This geometrical insight explains why nearly identically appearing ropes can be made from very different materials and it is also the reason behind the unyielding nature of ropes. Maximally rotated strands behave as zero-twist structures. Hence, under strain they neither rotate in one direction nor in the other. The necessity for the rope to be stretched while being laid, known from Egyptian tomb scenes, follows straightforwardly, as does the function of the top, an old tool for laying ropes.

Ac